Loading...
HomeMy WebLinkAboutOWTS System Layout & DetailsCONNECT 2" TRANSMISSION LINES INTO TWO MANIFOLDS MANIFOLS TO BE 1.5" DIA. SCH 40 PVC I SEPTIC 50' SET / I I I I I N201059.58 E117373.51 / I / / I I I I I I I ft N SEPTIC FIELD 25' SET BACK FIELD BACK 1 1 1 1 FLUSHING ASS EMT ENDBLY OAF I EACH ROW(TYP.) SEE DETAIL N201041.56 E117498.21 SIGNLE COMPARTMENT PRE -CAST 2,000 GAL TANK BARN -3 INLET USE TWO (2) 45 DEGREE BENDS TO ENTER TANK BARN -1 AND 2 INLET I 1 I I I I I tax MaiNUN Mal Nam Min Alt..ajj b Ian 711 Tamm 0, Lai g mum Imo Nam Num I sin I gas 0 12.00' A I I I I I I I I I N201071.48 E117375.23 SEPTIC FIELD 10' SET BACK I I I I I I N N201053.44 1 E117499.93 1 OS / IRR / RAW I I I INSPECTION RISER PORTS AT THE BEGINNING AND END EACH LATERAL (TYP.) 45 DEGREE BEND STA.4+59.30 0/S 0.00' 45 DEGREE BEND STA.4+52.75 0/S 0.00' SOUTH SEPTIC FIELD TWO (2) ZONES EACH WITH FOUR (4) ROWS OF 15 QUICK 4 INFILTRATORS IN A BED CONFIGURATION 1.5" SCH-40 LATERALS FORCE MAIN TWO (2) 1.5" DIA. SCH-40 PVC PRESSURIZE TRANSMISSION LINE FROM ADV DOWN TO STA as RAW IRR as as OF SEPTIC FIELD 100' SET BACK as - -I IRR / IRR / RAW / / / / as as IRR I IRR IRR RAW I- RA / / / / / SEPTIC FIELD 180' SET BACK �1 / / / / I I / I / 1// I // / I I I I as i i FORCE MAIN 1.5" DIA. SCH-40 PVC PRESSURIZE TRANSMISSION LINE FROM PUMP BASIN UP TO ADV / /5 DEGREE BEND / STA.2+97.85 / 0/s 0.00' \ / as as a / as as IRR IRR / IRR IRR IRR RAW RAW RAW �- / SEPTIC FIELD 100' SET BACK TIE INTO SOUTH SEPTIC TANKS STA.1 +81.90 0/5 0.00' INV. IN TO SOUTH 2,000 GAL, SIGNLE COMPARTMENT SEPTIC TANK STA.3+ 17.55 0/5 0.00' 45 DEGREE BEND STA.3+04.93 0/5 0.00' as sr�--as SEPTIC FIELD 180' SET BACK END OF BARN -3 SEWER SERVICE ALIGNMENT STA.1 +88.39 0/5 0.00' L7 // IRR .r IRR R as ir RA 0 FOR BAR SANITARY "Y" CONNECTION 0+74.00 .00' INV. IN TO SECIOND 2,000 GAL, DOUBLE SEPTIC TANK STA.3+32.72 0/5 0.00' L15 N SOUTH N COMPARTMENT N END OF BARN -1 AND 2 SEWER SERVICE ALIGNMENT STA.3+ 45.89 0/5 0.00' as IRR START SOUTH FORCE MAIN ALIGNMENT N201409.40 E117550.45 N \ \ 4" GAS LINE CROSSING STA.1 +03.57 \ 0/5 0.00' N N N N 10" GAS LINE CROSSING STA.1 + 12.98 0/5 0.00' I RA 6" GAS LINE CROSSING STA.0+94.79 0/5 0.00' as Graphic Scale 0 10 20 40 1 "=20' IRR IRR 1 ss ss IRR IRR RAW IRR ADV 45 DEGREE BEND STA.0+ 66.99 ALTERNATING DISTRIBUTION VALVE (ADV) ORENCO MODEL V6402A WITH ORENCO AIR VALVE ASSEMBLY TO BE PLACED AT HIGH POINT FORCED MAIN DISCHARGE LINE TO EXIT OUT SIDE OF TANK DOUBLE COMPARTMENT PRE -CAST 2,000 GAL TANK WITH PUMP BASIN IN SECOND CHAMBER SS- IS - • • TANK CONFIGURATION MIDDLE SEPTIC SYSTEM TANKS BARN -2 SANITARY SEWER CONNECTION N: 201292.711 E: 117583.961 45 DEGREE BEND STA.0+75.07 0/5 0.00' 45 DEGREE BEND STA.0+ 68.00 0/5 0.00' BARN -1 SANITARY SEWER CONNECTION 0/5 0.00' N: 201278.710 E: 117769.961 SS Fr 68 WS 10*209 SM \s if G"FtRE -\ L3 171 171 6"FIRE 1)0 ZO9 0 45 DEGREE BEND 45 DEGREE BEND 0/5 0.00' I cS SEPTIC FIELD 25' SET BACK SEPTIC FIELD 25' SET BACK SEPTIC FIELD 10' SET BACK ELECTRIC LINE TO POWER ORENCO PUMP 7 Fri 45 DEGREE BEND STA.0+32.93 0/5 0.00' 45 DEGREE BEND 0/5 0.00' BARN -3 SANATARY SEWER CONNECTION ..ailipap 10 ., ROARING FORK ENGINEERING 592 HIGHWAY 133 CARBONDALE COLORADO, 81623 PH: ( 970) 340-4130 F: ( 866) 876-5873 CHECKED BY: RBG DRAWN BY:VJT ASPEN VALLEY POLO CARBONDALE, CO 81623 Ca CO CC CC DESCRIPTION SOUTH OWTS PERMIT JOB #: 2017-13 FOR CONSTRUCTION o C 1 63/0 6300 6290 6285 63/0 68.00' OF 1" PVC 1.241 - CLEANOUT 6300 6290 6285 0 FINISHED GRADE 45° HORZ. BEND STA.0+75.05 EL E V.6298.23 45° HORZ. BEND STA. I +51.05 EL E V.6297.29 BARN -I SANITARY SEWER CONNECTION STA. -0+00.00 INV. OUT ELEV.6299.17 BARN-/ TO SOUTH SEPTIC TANK SANITARY CONNECTION SCALE: /"=20' HORZ. SCALE: /"=/0" VERT. 45° HORZ. BEND -STA. I +58.12 EL E V.6297.20 N 45° HORZ. BEND STA.2+97.85- EL E V.6295.47 EXISTING GRADE 26.71' OF 1"PVC 1.211- L 1/3.00' OF 1"PVC @ 1.211 7.07'OF4"PVC1,211 45° HORZ. BEND -STA.0+68.00 EL E V.6298.32 75.98' OF 4 -PVC 1.211 EXISTING GRADE ELEVATION Z07' OF 1"PVC 1.211 FINISHED GRADE ELEVATION TIE IN BARN -2 SEWER SERVICE STA.2+71.12 EL E V.6295.80 -7.07'OF1"PVC1.211 45° HORZ. BEND -STA.3+04.91 EL E V .6295.38 /2.62'OF1"PVC1.211 INV. INTO SOUTH SEPTIC TANKS STA.3+17.63 EL E V.6295.22 CLEANOUT 63/0 2000 -GALLON, SINGLE COMPARTMENT TANK 2000 -GALLON, TWO-COMPARTMENT TANK -5300 C:2:1, 0 0 Cr, LENGTH o o 1 I o o L12 S0°01'30"W 148.60' cri mc\; 6.86' L5 N90'00'00"W oN 0 N45°00'00"W 0 o m 41.30' co co co co co e co co e Cp 0+00 0+80 4' MAX BURIAL DEPTH 63/0 6300 6290 6285 63/0 6300 6290 6285 EXISTING GRADE 66.99' OF 1"PVC @ 1.211 - \_INV. OUT OF BARN -2 STA. -0+00.00 EL E V.6296.79 1+60 BARN -2 TO SOUTH SEPTIC TANK SANITARY CONNECTION SCALE: /"=20' HORZ. SCAL E : /"=/0' VERT. 45° HORZ. BEND TIE INTO LINE FROM STA.0+66.99- BARN -I WITH ELEV.6295.65 -SA NATARY "Y" STA.0+74.07 EL E V.6295.59 -1.211 2+10 45° HORZ. BEND STA./+00.81 EL E V.6295.38 45° HORZ. BEND STA. I +07.88 EL E V.6295.32 7./I'OF4"PVC/.21.0' VC 0)1.211 26.71' OF 1"PVC & 1.211 INV. INTO SOUTH SEPTIC TANKS STA. I +20.52 EL EV.6295.22 EXISTING GRADE -1I -FINISHED GRADE ELEVATION I ELEVATION 63/0 2000 -GALLON, SINGLE COMPARTMENT TANK 2000 -GALLON, TWO-COMPARTMENT TANK 6290 0+00 CLEAN OUT INV. INTO SOUTH SEPTIC TANK STA. I +81.90 EL E V.6295.22 0+80 BARN -3 TO SOUTH SEPTIC TANK SANITARY CONNEC TION SCALE: /"=20' HORZ. SCALE: /"=/0' VERT. 6" GAS LINE CROSSING STA.0+94.79- TOP OF PIPE ELEV.6296.30 4" GAS LINE CROSSING STA. I +03.57 TOP OF PIPE ELEV.6295.9I -EXISTING GRADE 6285 4' MAX BURIAL DEPTH 22.5° VERT. BEND STA.0+02.34-, EL E V.6301.33 1.79' OF 1"PVC & 11.181 5.32' OF 1"PVC 2.001 /8.30' OF1"PVC1.921 TWO (21 45 DEGREE BENDS TO CONVEY EFFLUENT 10" GAS LINE DOWN INTO TANK CROSSING STA.I+12.98 TOP OF PIPE ELEV.6295.30 2000 -GALLON, SINGLE EXISTING GRADE COMPARTMENT TANK ELEVATION 45° HORZ. BEND W/ CLEANOUT VERT. DEFLECTION STA.0+32.93 -STA.0+92.65 ELEV.6298.7I ELEV.6297.56 45° HORZ. BEND -FINISHED GRADE STA.0+14.64-1 ELEVATION ELEV.6299.07 3+20 6290 6285 4' MAX BURIAL DEPTH LINE TABLE 0 0 0 LENGTH o N0°00' 10"E o L9 Lp 7.01' L12 S0°01'30"W 0+00 CLEAN OUT INV. INTO SOUTH SEPTIC TANK STA. I +81.90 EL E V.6295.22 0+80 BARN -3 TO SOUTH SEPTIC TANK SANITARY CONNEC TION SCALE: /"=20' HORZ. SCALE: /"=/0' VERT. 6" GAS LINE CROSSING STA.0+94.79- TOP OF PIPE ELEV.6296.30 4" GAS LINE CROSSING STA. I +03.57 TOP OF PIPE ELEV.6295.9I -EXISTING GRADE 6285 4' MAX BURIAL DEPTH 22.5° VERT. BEND STA.0+02.34-, EL E V.6301.33 1.79' OF 1"PVC & 11.181 5.32' OF 1"PVC 2.001 /8.30' OF1"PVC1.921 TWO (21 45 DEGREE BENDS TO CONVEY EFFLUENT 10" GAS LINE DOWN INTO TANK CROSSING STA.I+12.98 TOP OF PIPE ELEV.6295.30 2000 -GALLON, SINGLE EXISTING GRADE COMPARTMENT TANK ELEVATION 45° HORZ. BEND W/ CLEANOUT VERT. DEFLECTION STA.0+32.93 -STA.0+92.65 ELEV.6298.7I ELEV.6297.56 45° HORZ. BEND -FINISHED GRADE STA.0+14.64-1 ELEVATION ELEV.6299.07 3+20 6290 6285 4' MAX BURIAL DEPTH LINE TABLE LINE BEARING LENGTH L8 N0°00' 10"E 66.99' L9 N44'41'49"W 7.01' 63/0 INV. OUT OF BARN -3 STA.0+00.16 EL E V.6301.40 6300 22.5° VERT. BEND STA.0+09.31 EL E V.6299.16 co 1 0 1 0 o 0 0 N L11 / +00 BARN -3 TO SOUTH SEPTIC TANK SANITARY CONNECTION SCALE: /"=20' HORZ. SCALE: /"=10' VERT. - -41 --- -107.66' OF- - -- 1.5" DIA. SCH-1 @-0.85/1 Q ORENCO ADV AT HIGH POINT IN LINE INV. IN EL E V.6298.00 STORM LINE CROSSING INV. ELEV.6290.49 0+00 EXISTING GRADE 6290 6285 --------------------- 315.82' OF LINE TABLE LINE BEARING LENGTH L10 S89°59'49"W 14.64' L11 S42'45'35"W 18.29' L12 S0°01'30"W 148.60' L13 N89°58'02"E 6.86' SOUTH SEPTIC TANK SYSTEM PUMP BASIN LINE TABLE LINE BEARING LENGTH L1 N90°00'00"W 68.00' L2 N45°00'00"W 7.07' L3 N0'00'00"E 75.98' L4 N45°00'00"W 7.07' L5 N90'00'00"W 139.74' L6 N45°00'00"W 7.07' L7 N0'00'00"E 41.30' EXISTING GRADE ELEVATION FINISHED GRADE ELEVATION /.5"01,4. SCH-1OPVC 1.00s FORCE MAIN INV. OUT - EL E V.6295.22 1+00 3+00 2+00 / +00 63/0 6300 6290 6285 0+00 LINE TABLE LINE BEARING LENGTH 1 I 6.49' L15 S43°46'59"W 1.56' L17 Cc,: P) o Cr, Cyj 0 0 0 0 0 0 C., C3.3 .. o 07 co co co co co co co co co co 1+00 3+00 2+00 / +00 63/0 6300 6290 6285 0+00 LINE TABLE LINE BEARING LENGTH L14 N90°00'00"W 6.49' L15 S43°46'59"W 1.56' L17 N90'00'00"W 100.99' L18 S49'06'57"W 6.55' L19 S8°13'55"W 3.82' ROARING FORK ENGINEERING 592 HIGHWAY 133 CARBONDALE COLORADO, 81623 PH: ( 970) 340-4130 F: ( 866) 876-5873 CHECKED BY: RBG DRAWN BY: VJT ASPEN VALLEY POLO CARBONDALE, CO 81623 DRAWN BY (I) DESCRIPTION SOUTH OWTS PERMIT JOB #: 2017-13 FOR CONSTRUCTION C2 DESIGN NOTES • DESIGN PER PERFORMANCE TEST PER ASTM C1227 • TOP SURFACE AREA 87.75 ft 2 • F'C W 28 DAYS: CONCRETE = 6,000 PSI MIN. INSTALLATION: • TANK TO BE SET ON 5" MIN. SAND BED OR PEA GRAVEL • TANK TO BE BACKFIL L ED UNIFORMLY ON ALL SIDES IN LIFTS LESS THAN 21 "AND MECHANICAL L Y COMPACTED • EXCA VA TED MATERIAL MAY BE USED FOR BACKFILL, PROVIDED LARGE STONES ARE REMOVED • EXCA VA TION SHOULD BE DEWA TERED AND TANK FILLED WITH WATER PRIOR TO BEING PUT IN SERVICE FOR INS TAL L A TION WITH WATER TABLE LESS THAN 2' BELOW GRADE • MEETS C/6.11-06 FOR RESILIENT CONNECTORS • INLET AND OUTLET IDENTIFIED ABOVE PIPE • PVC OR CONCRETE RISERS A VAIL ABL E TO MEET PROPOSED GRADE. • REFER TO THE VALLEY PRECAST INSTALLATION GUIDE FLEXIBLE BOOT INLET ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 0'- 0" 3'- 0" 7'- 0" 3'- 0" 2' - 0" 4' - 0" 3'- 0" 4'- 0" DRY 4' - 0" 13.50' TOP VIEW 24" MIN. HEIGHT I I- a. 4, 5" EFFLUENT FILTER 4" 4 /3.1 ' SECTION VIEW Digging Specs Invert ° ° V ° °d d ° ° ° ° ° ° ° 2__, O 10 20" CLEAR ACCESS \(Q Tank ° tl d d ° ° TOP VIEW 24" MIN. HEIGHT I I- a. 4, 5" EFFLUENT FILTER 4" 4 /3.1 ' SECTION VIEW Digging Specs Invert Dimensions Net Capacity Net Weight Lid Tank Total 75' Long x 8' Wide 4.66' below inlet invert lbs Inlet 4.66' Outlet 4.47' Length 75.5' Width 6.5' Height 5.6' 2,142 gal/ons 5,420 lbs 15,140 lbs 20,560 DISTRIBUTION PIPING HUNG FROM TOP OF QUICK 4 CHAMBER PVC CAP 2,000 GALLON SINGLE COMPARTMENT SEPTIC TANK FIELD LENGTH AND WIDTH PER PLAN TOPSOIL NATIVE BACKFILL 1.5" PERFORATED DISTRIBUTION PIPE SCH-40 PVC WITH $" ORIFICES SPACED EVERY 3' 34" O W TS BED INFIL TRA TION SYSTEM NTS IRRIGATION BOX WITH MAGNET GLUED INTO LID 4" SCH 40 PVC INSPECTION RISER WITH 2" VERTICAL SAW CUT 1-2" CONCRETE SAND 1.5" PERFORATED DISTRIBUTION SCH 40 PVC PIPE INSPEC TION RISER DETAIL NOT TO SCALE LID TO BE LEVEL WITH GROUND FILL MATERIAL 1.25" PVC SCH 40 LINE FROM INFILTRATOR 12" DESIGN NOTES • DESIGN PER PERFORMANCE TEST PER ASTM C1227 • TOP SURFACE AREA 87.75 FT2 • F'C @ 28 DAYS; CONCRETE = 6,000 PSI MIN. INSTALLATION: • TANK TO BE SET ON 5" MIN. SAND BED OR PEA GRAVEL • TANK TO BE BACKFILLED UNIFORMLY ON ALL SIDES IN LIFTS LESS THAN 24" AND MECHANICALLY COMPACTED • EXCAVATED MATERIAL MAY BE USED FOR BACKFILL, PROVIDED LARGE STONES ARE REMOVED • EXCAVATION SHOULD BE DEWATERED AND TANK FILLED WITH WATER PRIOR TO BEING PUT IN SERVICE FOR INSTALLATION WITH WATER TABLE LESS THAN 2' BELOW GRADE • MEETS C1644-06 FOR RESILIENT CONNECTORS • INLET AND OUTLET IDENTIFIED ABOVE PIPE • REFER TO THE VALLEY PRECAST INSTALLATION GUIDE 24" MIN. HEIGHT I— BUTYL RUBBER SEALANT OUTLET 4' MAX BURIAL DEPTH 6" MIN., NON -TRAFFIC AREAS 3' OF SAND MEETING GARFIELD COUNTY STANDARDS FINISH. GRADE -111 III -1 II—III 1-111-1 1=1 1=1 I I 11=111=11 I- i LATERAL FLUSHING DETAIL NOT TO SCALE 2" PVC SLIP X FPT ADAPT. W/ PLUG 10" HDPE HAND HOLD 2" BALL VALVE 2" PVC SPOOL 2" PVC LONG SWEEP 90° BEND NATIVE SOIL BUTYL RUBBER SEALANT FLEXIBLE BOOT INLET ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 0'- 0" 3'- 0" 7' - 0" 3' - 0" 2'- 0" 4'- O" .3' - 0" 4' - 0" DRY 4' - 0" 13.50' TOP VIEW 24" MIN. HEIGHT WIRES TO PANEL 24" MIN. HEIGHT QUICK DISCONNECT BALL VALVE t 13.08' '"Service contracts available forrmaintenance * SECTION VIEW Digging Specs Invert Dimensions Net Capacity Net Weight Ill ° Outlet d s S . 4 ° ° d Outlet 20" CLEAR ACCESS Lid Tank Total (Q 0 75.5' 6.5' 767' 7559 gal 507 gal 2066 gal TOP VIEW 24" MIN. HEIGHT WIRES TO PANEL 24" MIN. HEIGHT QUICK DISCONNECT BALL VALVE t 13.08' '"Service contracts available forrmaintenance * SECTION VIEW Digging Specs Invert Dimensions Net Capacity Net Weight 75' Long x 8' Wide 4.67' below inlet Inlet Outlet Length Width Min. Height Inlet Side Outlet Total Lid Tank Total 4.67' 6.08' 75.5' 6.5' 767' 7559 gal 507 gal 2066 gal 5420 lbs 75550 lbs 27750 lbs 2 000 GALLON TWO COMPARTMENT SEPTIC TANK WITH HIGH HEAD PUMP TOP VIEW ORENCO V&/02 PVC ENCLOSURE IN 30" DIAMETER ONLY STAINLESS STEEL BOLTS AND URETHANE GASKET FINISHED GRADE AIR RELEASE VALVE 30" PVC ENCLOSURE FROM PUMP MIN. 1% 6000 SERIES 1.5" INLET & OUTLET 15 - 100 GPM FLOWRATE HOSE 24" SIDE VIEW 8 MIN. 1% FLOW TO TANKS TO FIELD 1.5" OUTLET PIPE 6"-8" GRAVEL BASE AUTOMATIC DISTRIBUTION VALVE ORENCO V6102 AUTOMATIC DISTRIBUTION VAL VE DETAIL NOT TO SCALE OUTLET TO ADV DRILL %6" HOLE IN ELBOW FOR DRAIN BACK ORENCO DUPLEX PUMP (PF500552) NOTE: WATER AND SEWER SERVICE LINES ARE REQUIRED TO BE A MINIMUM OF 10' APART PVC CAP 1"" DEEP SAW CUT PVC CLEANOUT, VENT, OR OBSERVATION PIPE OBSERVATION PORT / CLEANOUT CAP NOT TO SCALE 45 MJ WYE OR ELBOW 4" PVC 7 -EXISTING DIRT OR TOPSOIL AREA 1 I—III-III-III-III-III- I I -III -I I 1-1 11 1=1 1=1 1=1 11 1=1 1- 111-111-111-111-1 I-111=1 1 I-111-111-1 1 1-1 1 1 III—III—III—III-1 1-I 11—I I I—I I I—I I I—.. . 1-111-111-11I— 11— I1111 1 111 MIN. Avitpti its `Iti it* —iii C31T D NATIVE MATERIAL (3" MINUS) 0 S 6 AGGREGATE AS DETERMINED COMPACTION DENSITY OF 95% " ASTM D698 I I I E OGRET-ATE BASE COURSE COMPACTION R -4S -11M D698 SEWER TRENCH DETAIL NOT TO SCALE PLUG CONCRETE SUPPORT COLLAR CLEANOUT DETAIL NOT TO SCALE 45 MJ ELBOW --.1111111 9 DIRECTION OF FLOW ROARING FORK ENGINEERING 592 HIGHWAY 133 CARBONDALE COLORADO, 81623 PH: ( 970) 340-4130 F: ( 866) 876-5873 CHECKED BY: RBG DRAWN BY: VJT ASPEN VALLEY POLO CARBONDALE, CO 81623 DRAWN BY (I) 1 DESCRIPTION SOUTH OWTS PERMIT � � I JOB #: 2017-13 FOR CONSTRUCTION C3