HomeMy WebLinkAbout14. Master Utility Sheet 7MATCH LINE SHEET 30
I.
,``
60' MIN. UTILITY LEGEND
*CID
\ D
S DBL.
`0 \ I �,. / Ga �� v �' a'UST -oE OE- EXIST/NG OVERHEAD ELECTRIC
4
vEXISTING
> ti MH -D2 / H -H2 GAS
/ / NEW LATERAL/ `�1
by
IRRIGATION DITCH / PIIlriG-WA�6--- EX/STING WATER
6"
J+ / 'tR/� - \IRR
`� / IR.,
Or, y /
1+
co /
H - El 0
OUT 6453
RRIGATION RISER+VA +HOOD - F 12PIP SDR¢IRRIIRR /‚I\
IRR + 541 KCULVERT 13 C ✓
IRR /1o /,
{�D
/ 6' IRRIGATION RI/�HOOD ^ / 1
/ 1
\
:IDIP
EXISTING RAW WATER IRR/GA770N
(�I64O/INV
\ OS EXISTING SANITARY SEWER MANHOLE
EXISTING WATER SHUTOFF
EX/STING GAS METER
/ O EX/STING STORM DRAIN MANHOLE
/ ''�> EXISTING U77L/TY POLE
AL
/ \
/ cx EXIST7NG LIGHT POLE
j / INV CUT- 6468.0 3
I' RIGATION PIPE 8 /43 \/
�' /
R��tiV��GE SW . / EX/STING PAVEMENT
_
175 LF 6" PIP SDR -41 / -.
/ '%�� •G '-
Zl0• / \r' `'�8' ALVE \ •
^- ABAN • e ICH( \
FIRE HPDR j -Sr
/ / \ g PROPOSED FORCED SEWER MAIN
(�J L TL' GATE V'1'. -. \ �X
p N —ETC
/ / .y- _. ETC— ELECTRIC.
- \
" :"i: TEE '; - N. .
_ �� E -1/-C SERVICEPROPOSED UNDERGROUND
,_ AND CABLE
l/ 11 4
rid / -- - :. • 'BEND \ �\ MH -E11 , _�, LOTS 65 & 66TELEPHO-GAS
I
GAS PROPOSEDNE
' x GAS WIN
/ / i74 LF 15' ADS -N12 \ '11, —35
22 1 2' Baaalli '•y
THRUST = •«� \ 4 22 1/2' ss— PROPOSED SEWER MAIN
RT 12
i p �� \•' N. INDIVIDUAL MP •
/
/ / ,l g LOCK —W W— PROPOSED WATER MAIN
A 00 S/ LOCK ' r._� \� % CONNECTI« '• O� >
,
/ • TION ��
.R ., - WALE ss PROPOSED SEWER SERV/CE
2+00 / �\I
' ; � � it--�- �-. \ TOTE
_.-;\. �st� I \ SYSTE FOR
\ �J
/ _. •^--� w `.' ,--� N
/ y `O LOTS •2, 6?15•
\ 68 69 4'
F. SW' /�
DE BO ' OM
• = 6461.5 4' WIDE BOTTOMi PROPOSED WA TER SER NCE
4:1 SIDE SLOPE TO DAYLIt T PROPOSED SANITARY SEWER MANHOLE
/ OVER TOP OF CULVERT
/ 4 . S PROPOSED FORCED MAIN SEWER MANHOLE
�� �� ,. ► \ 8" GATE _LVE / O
/ ,/ 3 \ 4:1 : DE SLO TO DA GHT FIRE HYDRA
7-1'
- _ _ \ \/ 0 R TOP « LVERT
' /107 LF. :` D • /��� _ _ �.- > \ \ ABAND• DITCH 6" GATE VAL��,\ . WER UNE 'E`I PROPOSED FIRE HYDRANT
wv
N / 8" X 8" X 6" a
/\\/
LF. 8" DIP THRUST BL•«PROPOSED
I111 LF. 8DIP \ -!
F.8'DIP \./
//4
WRIER PALL'S
E PROPOSED ELECIC MANHOLE
O71
I �\ -IRR—IRR- PROPOSED /RRIGA770N PIPING
A
Oji 9
\
\l O PROPOSED DRAINAGE BASINS
,
/ IIQV N=6479.5 r‘C,'
3+00
\ , \
\45' By` • •
, \ PROPOSED LOT LINES
\ \ • cANDON DITCH �/\ 4 PROPOSED EASEMENTS
I \\\� \
rn
THRUST Bt f�/L
\
N. \ PROPOSED PAVEMENT
I
20 :^
- _ -, %'\ „\ \
E -T-9 SERVI '��•`�
\ O /
///////1 PROPOSED MILLED PAVEMENT
a
o
ziA
LA
\ 8. \ 4.
LOTS 49 do 50 \`\ \ \ --)t.A. _\ \ \ /
\ \ \ \ / \ Fir O \ `�
./
\ \\ \ \ \ _ \' N \ \c \- E -T -C SERVICE �0i O •
\ N \ LOTS 67 M 68 ADS
N
A
LA\��\\\\\\�
V A ' \
._+p',stfi,L
/\F
c :�i--
A�`s\\�
\FIRE
6"GATEVLVE
. • 253 LF 36" -N12
N A \ 1 4y, M -E12 CULVERT 13
EOTS 63 do 64E 10' WIDE RIP RAP
V A8'-GATE'VALVE \/I)
HYDRANT\ \bs70
\\ i _ _ _ I �J.
Il a
•'
-BEND limmellir
\THRUST BL \ w'
/ \ o \ 5" _
A \ A THRUST BLOCK
Oy 9 \ V a5 BIND
+oo
-�
20 TO
DRAINAP WALE \THRUST BLOCK *CD
\ \
/ 1A \\
\ A 7 \ A \ �1. N 93 L.F. 8" DIP la s
r
u• �70,
/ .• V
/ N. \ \ \ N
j,\n' V I N A \ V N
49 LF. 8`\\'` \ 11 1U4 BL�OCKII \\ \ \ \ \ \ \ N \ \ \ \ N. \ \ ABANDON DITCH
/
S11
CV
to
W
w
w
z
-21
1
Q
/
7 00 6
i+oo
A
' .,,�
��
00 O1
I+00
- 1%1
N
v
I
0
�, I
1
'
3,1%4_, I
3,,►�—_3., I �,
E -T -C SER ��
OTS 42, 43 d� 61 ���/�"_•;
1
1
•
��
..
t■il
24
-_,_.,,,s,,
���
I
1
1I
1
'
I
cs
yJ
\
v
\
II
CO
1 I
I \,
I O\
,\ , 1
\
`-
, \
v
i
�, \
V
,
\ \
\ (
\THIS AR
N, v v v v,
--- _
N \ � �Y \v --- \
�_ THI
�\
��\ \\\\' o \��,SEW
\ \ \ --...-
\\ \\ \\ �� \ PHASE—
\ \ ----, \ N.
N. A� \ V -
v
\ \
. �\ s`�O \�\
_
A
_
_ -6�
CONSTR
:___,A2,_,T,ER, ETC.
�.
� _
—
86
_,
- - -
__—
/
Ao --
�-
i+00
1114
�� ��
vNN
O \ /
M -D6
,/ I
/ I
SEWER UCpE
\
\ \
:, ` r
_
' \
( /
/ /
I
\
`,
I I
/
`
/
SEWER,\\W•�TER, ETC:\
PHASE MI C�NSTRUCTI
I I \
/
1
\N_, �,---- ' --
Nv �vv --�, ____
_` '
\ \ \ \ \ \ \ \
\ \ \� ,�
Ss
■
�\ I� �� MH -k7
�
-
�� '\ \` \\� ���\ __�
\
FOR
327 LF. - "SDR �..,:I.ni� `_ 'r \_ -- _ N.
8 35 8 ��' ` \
\ \ \ \ \ \ \
C❑NSTRUCTI❑N
MATCH LINE SHEET 36
GENERAL UTILITY' NOTES:
/�
/ \
6/27/07
PROPOSED WELL #3
JPP
3/27/07
PHASE 1 & 2 AS- BUILTS
JPP
1. THE LOCATIONS OF UNDERGROUND UTILITIES 3. MAINTAIN A DISTANCE OF 10 FEET BETWEEN 5. ALL UTILITIES, BOTH UNDERGROUND AND 8. THE CONTRACTOR IS TO NOTIFY WATER USERS 11. ALL SEWER LINE CONSTRUCTION SHALL BE IN
24 HOURS IN ADVANCE OF' ACCORDANCE WITH THE RULES AND
C
5/12/05
GARFIELD COUNTY COMMENTS
RTM
HAVE BEEN PLOTTED BASED ON UTILITY MAPS, WATER LINES AND SANITARY SEWER LINES OVERHEAD, SHALL BE MAINTAINED IN ANY WATER SHUT
CONSTRUCTION/DESIGN PLANS, OTHER (EDGE TO EDGE). IF THIS IS NOT CONTINUOUS SERVICE THROUGHOUT THE ENTIRE DOWN. MORE NOTICE MAY BE REQUIRED FOR REGULATIONS OF THE GARFIELD COUNTY PUBLIC
B
5/2/05
REDESIGNED ELECTRIC SERVICE
RTM
INFORMATION PROVIDED BY UTILITY POSSIBLE, THE ELEVATION OF THE CROWN OF CONSTRUCTION PERIOD, EXCEPT AS NOTED IN MAJOR CONNECTIONS. WORKS DEPARTMENT.
NO.
DATE
REVISION
BY
50
0 25
-
I.
GRAPHIC SCALE
50 100
200
COMPANIES AND ACTUAL FIELD LOCATIONS IN THE SEWER SHOULD BE AT LEAST 18 INCHES THE SPECIAL CONDITIONS. THE CONTRACTOR
SOME INSTANCES. THESE UTILITIES, AS BELOW THE INVERT OF THE WATER MAIN. IF SHALL BE RESPONSIBLE AND LIABLE FOR ANY 9. THE CONTRACTOR IS RESPONSIBLE FOR
SHOWN, MAY NOT REPRESENT ACTUAL FIELD NEITHER OF THESE ARE POSSIBLE, DAMAGES TO, OR INTERRUPTION OF, SERVICES COORDINATION AND SCHEDULING, TO THE BEST
CONDITIONS. IT IS THE RESPONSIBILITY OF CONSTRUCTION SHALL BE DIRECTED BY THE CAUSED BY THE CONSTRUCTION. OF HIS ABILITY, FOR THE INSTALLATION OF
CONTRACTOR TO CONTACT ALL UTILITY ENGINEER. NATURAL GAS, ELECTRICITY, CABLE
COMPANIES FOR FIELD LOCATION OF 6. THE CONTRACTOR SHALL CONTAIN HIS TELEVISION AND TELEPHONE UTILITIES.
COMPANIES
TO CONSTRUCTION. 4. ALL MAIN LINE AND HYDRANT VALVE BOXES CONSTRUCTION OPERATIONS WITHIN
GARFIELD COUNTY
SPRINGRIDGE RESERVE
PUD
UTILITIES PRIOR
(Thi FEET ) LOCATED IN THE ASPHALT SHALL BE BROUGHT THE R.O.W. AND THE SPRINGRIDGE RESERVE 10. ALL WATER LINE CONSTRUCTION SHALL BE IN
SUBDIVISION SITE. THE CONTRACTOR ACCORDANCE WITH THE RULES AND
2. ALL WATER MAINS SHALL BE INSTALLED WITH TO 1/4 INCH BELOW FINISH GRADE
1 inch = 50 ft. A 5'6" MINIMUM DEPTH OF COVER. SERVICES ELEVATIONS. SHALL NOT OPERATE OUTSIDE THIS AREA WITHOUT REGULATIONS OF THE GARFIELD COUNTY PUBLIC
SHALL HAVE 5'6" OF COVER. IF GRADE THE PRIOR EXPRESSED CONSENT OF THE PRIVATE WORKS DEPARTMENT.
SOPRIS ENGINEERING, LLC.
MASTER UTILITY
SHEET 7
CONFLICTS OCCUR WITH EXISTING UTILITIES, OWNER OR SPRINGRIDGE RESERVE SUBDIVISION
?IVIL CONSULTANTS'
THE PROPOSED WATER MAIN GRADE CAN BE REPRESENTATIVES.
VARIED PROVIDED THAT THE MINIMUM DEPTH
502 MAIN STREET, SUITE A3
DES. RTM
CK. YTN
FILE NO.
SHEET 33
OF COVER IS MAINTAINED.
24040\AID-FinalFfan\Cover MU.dwg
CARBONDALE, COLORADO 81623
(970) 704-0311
DR. RTM
DATE 6/23/04
24040.01
OF 85