The Slayton 60, Slayton 42S and Slayton 36 models (Electronic Ignition) comes standard with a decorative black curved
firebox lining, remote modulating valve system w/ flame, fan & Light adjustment. (remote control & light kit included)
Modal
Height
SI 60
Slayton 42S
Slayton 36 -.
31-1/16"
32-9/16"
28-13/16"
Width
66"
50"
43-5/8"
Back Width
66"
50"
43-5/8"
Depth
15-13/16"
15-13/16"
15-13/16"
Weight
300 lbs.
220 lbs.
200 lbs.
Viewing Area
14-1/4" x 58-3/8"
15-11/16" x 42-3/8"
14-1/16" x 36"
NG High / Low
55,000 / 17,500
42,000 / 21,000
33,000 / 17,000
LPHigh /Low
55,000 / 17,500
42,000 / 21,000
33,000 / 17,000
ENERGUIDE P.4 NG /LP
73.31% / 75.28%
72.21% / 75.53%
66.05% / 68.05%
Steady State NG / LP
68,6% / 70.5%
72,98% / 75.45%
71.21% / 73.05%
AFUE % NG / LP
66.44% / 68.27%
68.05% / 70.39%
65.74% / 66.84%
Valve System
IPI
IPI
IPI
Split Flow Burner
Standard
Standard
N/A
Standard Refractory
Enamel (curved)
Enamel (curved)
Enamel (curved)
Glass Media
Required
Required
Required
Accent Medla
Optional
Optional
Optional
Ceramic Media
Standard
Standard
Standard
Fan Kit Availability
Optional
Optional
Optional
Finishing Trim Kit
Standard
Standard
Standard
Screen Front
Required
Required
Clearances
ores, options & Specifications are subject to change.
10#
ME
Slayton 60
Sfalyton.42S.
Slayton 36. 11.1
Top of unit face to framing
5-3/4"
10-11/16•
7-3/4"
From unit left & right side stand-
offs & back
d•
0"
0"
Top of finishing edge to ceiling
31-3/16"
36"
36"
Side of finishing edge to adjacent
sidewall
6"
6"
V,
Unit front to combustibles
36"
36"
36"
Mantel projection from fireplace
finishing edge*
14-1/4"
*9" deep projection
14-1/4"
*9" deep projection
14-1/4"
*1" deep projection
Refer to the installation manuals for c mplete installation & venting requirements.
See additional mantel clearance co figurations in the installation manual.
Eachunit factory tested
Certified to ANSI Z21.88 Vented Gas Heaters
Vent System & Requirements
MS G&U.vlace is manufactured to Moot 5"k 8" rigid and flexible airlq,
• Simpson Dura-VentTM DV -PRO pipe - 5"x 8"
• Selkirk MetaIbastosTM direct chimney system - 5"x 8"
• Ameri-Vent/American MetaITM direct chimney system - 5"x 8"
• Metal FabTM 5"x 8"
• ICCTM 5"x 8"
• Kozy HeatTM flexible 41800 series vent kits* - 5"x 8"
• BDMTM direct vent chimney system - 5"x 8"
IMPORTANT: The horizontal heat shield included with this fireplace must be
installed when incorporating minimum horizontal venting.
Elbows: For each additional 90° elbow used after the first elbow, 3' must be
subtracted from the maximum venting allowed. For each additional 45' elbow used
after the first elbow, 144' must he subtracted from the maximum venting allowed.
Note: (2) 45' elbows = (1) 90°elbow
Maximum number of elbows for ALL vent configurations= 5
Horizontal Terminations. Venting configurations vary between NG & LP Gas, please
consult the installation manual for requirements.
Vertical Terminations; Minimum: 2' Maximum: 50'
ygrggotaVVertical Cerullo.; Venting configurations vary between NG & LP Gas,