HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-05-19-5743 and SEPT -05-19-5744
Ian & Kristin Byman
Single -Family Residence + Garage/Shop
Manufactured Steel Building
Antlers Orchard, Tract 9 — Rifle, Colorado
1) ALL WORK SHALL COMPLY WITH 2015 I.R.C., I.B.C., I.F.G.C., I.F.C., AND 2009 I.E.C.C., AS
WELL AS MANUFACTURER'S INSTALLATION REQUIREMENTS.
2) IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED
"GARFIELD COUNTY BUILDING REQUIREMENTS". NUMBERED REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) BUILDING IS APPROVED AS A SINGLE-FAMILY RESIDENCE + GARAGE/SHOP. ANY CHANGE IN
USE OR OCCUPANCY (FOR EXAMPLE, COMMERCIAL USE) MUST COMPLY WITH GARFIELD
COUNTY'S LAND USE & DEVELOPMENT CODE. IF THIS RESIDENCE IS EVENTUALLY INTENDED
TO SERVE AS AN ACCESSORY DWELLING UNIT, THEN IT MUST COMPLY WITH 1,000 SQUARE
FOOT MAXIMUM SIZE, OR A SUBSEQUENT LAND USE CHANGE PERMIT FOR A "SECONDARY
DWELLING UNIT" WILL BE REQUIRED.
4) AN OPEN -HOLE SOILS REPORT AS PREPARED BY A COLORADO LICENSED PROFESSIONAL
ENGINEER IS REQUIRED AT FOOTING INSPECTION TO VERIFY 2,000 P.S.F. MINIMUM SOILS
BEARING CAPACITY. PROVIDE COPY OF REPORT FOR BUILDING INSPECTOR REVIEW AT
FOUNDATION INSPECTION.
5) ON-SITE WASTEWATER TREATMENT SYSTEM TO BE DESIGNED AND INSPECTED BY A
PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO. PROVIDE COPY OF
O.W.T.S. DESIGN FOR INSPECTOR REVIEW ATJOB SITE. ENGINEER'S FINAL REPORT
REQUIRED PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY.
6) HIGH-STRENGTH BOLTING & FIELD WELDING REQUIRES SPECIAL INSPECTOR PER "SPECIAL
INSPECTIONS" PROVISIONS OF I.B.C., CHAPTER 17. PROVIDE COPY OF APPROVAL REPORT
AT FRAME INSPECTION.
7) PROVIDE FIRE SEPARATION BETWEEN RESIDENCE AND GARAGE/SHOP AS PER ITEMS #45,
46, 47 AND 48 OF PLAN ATTACHMENTS.
8) A MINIMUM OF ONE WALK-THROUGH SIDE -HINGED DOOR (MIN. SIZE: 36" WIDE X 80" HT.)
IS REQUIRED FOR EGRESS FROM WITHIN THE GARAGE/SHOP.
9) INSULATION AT THERMAL ENVELOPE AS PER 2009 I.E.C.C., TABLE 402.2.5 AND PAGE ONE OF
PLAN ATTACHMENTS. RADIANT FLOOR SLAB TO BE INSULATED WITH R-15 INSULATION AT
SLAB EDGE AND R-5 BELOW SLAB PER I.R.C., SECTION M2103.
10) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD.
ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL FINAL
APPROVAL 15 REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.