Loading...
HomeMy WebLinkAboutOWTS Design 06.29.17Rtt ilililff 33 Four Wheel Drive Rd Corbondole, CO 8ló2t 910.309.t1t9 Ë{ECNTVHffi JUL 1 2 ?017 GARFIELD COUI'¡TY I h4M UNïTY tlËVËLÛPt'ûËl{T June 29,2017 Project No. C1297 Ryan Pratt Rpratt2311@qmail.com Onsite Wastewater Treatment System Design 4-Bedroom Residence + 1 Future Bedroom Lot A, Panorama Reserve Garfield County, Colorado Ryan, ALL SERVICE septic, LLC has completed an onsite wastewater treatment system (OWTS) design for the subject residence. The 8.1 17-acre property is located outside of Carbondale, in an area where OWTSs and wells are necessary. Legal Description: Section: 17 Township: 7 Range: 87 Subdivisionr PANORAMA RESERVE SUB-DIV Lot: A AMD REC# 772442 Parcel ID: 2391 -17 4-02-OO1 SITE CONDITIONS The property is currently undeveloped, with the exception of a well and cistern that is shared with two other lots in the Panorama Reserve Subdivision. A 4-bedroom residence is proposed. The OWTS will be sized to accommodate the 4-bedroom residence and 1 future bedroom. Potable water will be served to the residence from this well, which is located on the northeastern portion of the property greater than 50-feet from the proposed septic tank and greater than 1OO-feet from the proposed soil treatment area (STA) The proposed STA location has approximately a ten percent slope to the southwest. The proposed STA is covered with sage, scrub oak and native vegetation. SUBSURFACE The subsurface was investigated by HP-Kumar on August 18, 2016. The report dated August 30, 2016, Project Number 16-7-326 is enclosed. One soil profile test pit excavation and three percolation test pits were excavated. The soil profile consisted of 6-inches of topsoil, underlain by reddish brown sandy silÇ clay to 2- feet, underlain by light brown, dense calcareous sandy silty clayey basalt gravel and cobbles to a maximum depth explored of 6.5Jeet where they encountered practical digging refusal. No groundwater or bedrock was encountered. Percolation test results were 30 minutes per inch (MPl) in Hole P1 and 20 MPI in Holes P2 and P3. Based on information provided in this report, we are sizing the STA based on Soil Type 24. A long term acceptance rate (LTAR) of 0.5 gallons per square foot will be used to design the OWTS, in accordance with Table 10-l Soil Type 2A presented in the Garfield County On-Site Wastewater Treatment System Reg u lations, adopted Aprll'l 4, 201 4. Page2 DESIGN SPECIFICATIONS Desion Calculations: Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 150 GPD (4th and 5th bedrooms) = 600 GPD LTAR = 0.5 GPD/SF 600 GPD / 0.5 GPD/SF x 1.0 (gravity trenches) x 0.7 (chambers¡ = 840 SF The OWTS design is based on S-bedrooms. An average daily wastewater flow of 600 GPD will be used. The system installation will include a 1500-gallon, two-compartment concrete septic tank with an effluent filter installed on the outlet tee of the septic tank. The septic tank may not be buried more than 4-feet below grade and risers must be used to bring the manhole lids to grade for access. Effluent will gravity flow from the septic tank to a distribution box, which must be accessible from grade. Flow equalizers, or similar product, must be installed on each pipe exiting the distribution box to equalize flow to each trench. The STA will consist of five rows of 14 'Quick 4' lnfiltrator@ chambers, for a total area of 840 square feet of infiltrative area. The infiltrative area may not exceed 4-feet below native grade. We recommend installation of the infiltrative area just below the reddish brown sandy silty clay horizon. lnspection ports must be installed at both the beginning and end of each trench. These ports may be cut to grade and covered with a sprinkler box for access. The component manufacturers are typical of applications used by contractors and engineers in this area. Alternatives may be considered or recommended by contacting our office. Construction must be according to Garfield County On-Site Wastewater Treatment System Regulations, the OWTS Permit provided by Garfield County Building Department, and this design. REVEGETATION REQUIREMENTS An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire disturbed area of the OWTS installation. A mixture of native grass seed that has. good soil stabilizing characteristics (but without taproots), provides a maximum transpiration rate, and competes well with successional species. No trees or shrubs, or any vegetation requiring regular irritation shall be placed over the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation cover. OPERATION INFORMATION AND MAINTENANCE The property owner shall be responsible for the operation and maintenance of each OWTS servicing the property. The property owner is responsible for maintaining service contracts for manufactured units, alternating STAs, and any other components needing maintenance. Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials should be placed on backfilled STAs. Livestock should not graze on the STA. Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA. lf an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned annually, or as needed. lf the OWTS consists of a pressurized pump system, we recommend the laterals be flushed annually, or as needed. Page 3 The homeowner should pump the septic tank every two years, or as needed gauged by measurement of solids in the tank. Garlcage disposal use should be minimized, and non-biodegradable materials should not be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS. Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste only. ADD¡TIONAL CONSTRUCTION NOTES lf design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of freezing. The pump shall have an audible and visual alarm notification in the event of excessively high water conditions and shall be connected to a control breaker separate from the high water alarm breaker and from any other control system circuits. The pump system shall have a switch so the pump can be manually operated. Excavation equipment must not drive in excavation of the STA due to the potential to compact soil. Efensions should be placed on all septic tank components to allow access to them from existing grade. Backfill over the STA must be uniform and granular with no material greater than minus 3-inch. INSTALLAT¡ON OBSERVATIONS ALL SERVICE septic, LLC must view the OWTS during construction. The OWTS observation should be performed before backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the installation. LIMITS: The design is based on information submitted. lf soil conditions encountered are different from conditions described in report, ALL SERVICE septic, LLC should be notified. All OWTS construction must be according to the county.regulations. Requirements not specified in this report must follow applicable county regulations. The contractor should have documented and demonstrated knowledge of the requirements and regulations of the county in which they are working. Licensing of Systems Contractors may be required by county regulation. Please call with questions. Sincerely, ALL SERVICE septic, LLC Reviewed By (s.ab û*fur1 Richard H. Petz, Carla Ostberg, MPH, REHS 8s662 +7./NÆ/6o(E-7=o(3çÕaÐzDESIGN+!S.BEDROOM RESIDENCE(75 GAL/PERSON/DAY x 2PERSONS/BEDROOM x 3 BEDROOMS) +(150 GAL 4th AND sth BEDROOMS)WASTEWATER FLOW = 600 GALLONSTANK:5-BEDROOMS = MlN. 1500 GALLON,TWO-COMPARTMENT SEPTIC TANKIÐmoi@_/ISOIL TREATMENT AREA (STA):LONG TERM ACCEPTANCE RATE (LTAR) =0.5 GAL/ SQ FTCALCULATED STA = Q/LTAR = 600 / 0.5 =1200 sFGRAVITY, CHAMBER TRENCHES = 1200 SFX 1.0 X 0.7 = 840 SFFIVE GRAVELLESS CHAMBER TRENCHES14'QUICK 4'CHAMBERS IN EACH TRENCHTOTAL 70'QUICK 4' CHAMBERSmz4o\ìls{ocIzmi@o\,/o' 25' 50,Scale: 1" = 50'=0"w1 .0Date: 06129/17 IOes¡gneO gv: CgOlReviewed By: RHPIDEm Bv:ANG ISheet 1 of 3Pratt ResidenceLot A, PanoEmâ ReserveGarfi eld County, ColoradoPrcjectNumber C129733 Four Whed Drire RoadCarbondale, CdoEdo 81623Phone 970.309.5259carla@allserviæseptic.æmML$tnilüA{¡L' N\'\\I\I1\4" DtA SDR-350'10'e'2O'=0iWITH DOUBLE-SWEEP--- CLEANOUJ (MtN.2ol" SLOPETOTANK) \\cale:1".==_72eo\\\ACCÈSQArD-BOX WITHGRADE'QUtCK-4'TRENCHES. S14CHAMBERS = 70840 SFCHAMBERQ:\o'\. \4" DIA SDR-35 SEWER LINE EACHTRENCH (MtN. 1% SLOPE)%s.BEDROOMRESIDENCEDate: O\ngfl IIDesisned By: cBol W2.0Reviewed By: RHPIDmwn Bv: ANG I sheet 2 of 3Pratt ResidenceLot A, Panorama RæryeGarfield County, ColorâdoPrcject Number: C12970tt$lnrffi33 Four Whæl Drive RædCarbondale, Colorado 81623Phone 970.309.5259carla@allseruicesept¡c.com,d[ü INFILTRATOREND PLATEGRAVELLESS 'QUlCK.4'CHAMBER (4' x 3')4- DIA SDR-35 SEWERLINE TO EACH TRENCH(MtN. 1% SLOPE TOTRENCH)4" DIA SDR.35EFFLUENT PIPE FROMSEPTIC TANKSLIP-ON PVCDO NOT GLUESEWER LINES TOOTHER TRENCHESDIA SDR.35IINSPECTIONPORTFINISHED GRADEBOX WTH6'ACCESS AT GRADEtSOIL2'minl4" DIA SDR-35SEWER LINEPLACED INLIMITOF4' DIA SDR-35 INSPECTIONPORT AT BEGINNING ANDEND OF EACH TRENCHTOP PORT OFCHAMBER ENDPTATESEXCAVATIONSCARIFY SURFACEGRAVELLESS'ourcK4'CHAMBER (4',x 3')TOTANK TO HOUSE/-ì CLEANOUT DETAIL^STA SECÏONYJ rcrÞru\:-iolÞwSMALL VALVE COVERBOX OR IRRIGATIONVALVE BOX AT GRADEBOX AND COVER BROUGHT TO GRADECAP OR THREADEDcoNcRErELlD--1CLEANOUT ASSEMBLYFINSHEDGRADECOMPACTBASE TO SUPPORTBOXPVC PIPE CUTTOFITt2'USE HOLE SAW TOCUI THRU TOP OFLINES TO ENTERAND EXIT IN TOPPORT OF CHAMBERBAFFLE OREND PLATEDISTRIBUTION BOXANGLED PIPETO BE USEDAT INLETEND PLAÏE/.à CHAMBER DETAILS\y ffircsÆ/.À D-BOX DEÏAIL\y þ1Þ$e14 CHAMBERS PER TRENCHIIOUTLETSoooow3.0Datei O6l2gt17 IOes¡gne¿ gv: CAOIReviewed By: RHPIDÉwn Bv:ANG ISheet 3 of 3Pratt ResidenceLot A, Panorama ReseryeGarfield County, CdoEdoProiect Number: C129733 Four Wheel Driw R€dCarbondale, Colorado 81623Phone 970.309.5259carla@allsery¡æsept¡c.æmNH$tffir[f Item # {500T-2CP íSOO Gallon Top Seam Two Gompartment DESIGN NOTES¡ Design per performonce test per ASTìI cl227 r Top surfoce oreo 62.33 ft'z r fc @ 28 do)rs; concrete : 6,000 PSI Min. lnstollotion: ¡ Tonk to be set on 5" min. sond bed or peo grovel¡ Tonk to be bockfìlled uniformly on oll sides in lifts less thon 24" ond mechonicolly compoctedr Excovoted moteriol moy be used for bockfill, provided lorge stones ore removedr Excovotion should be dewotered ond tonk fllled with woter prior to belng put in service for instollotion with woter toble less thon 2' below groder Meets C1644-06 for resilient connectors¡ lnlet ond Outlet identified obove pipe ¡ Delivered complete w¡th internol P¡Ping¡ PVC or concrete risers ovoilobler Secondory sofety screen ovoiloble with PVC riser. Option of pump or siphon instqlled ZFCL.r^cü 6l J' ft*IL'o_-l.L Top View Butyl Soalant Bod ALLOWABLE BURY (Bosed on Woter Toble) WAÏER TABLE ALLOWAELE EARÏìI FILL 0'- o'3'- O" t'- o"3'- O" 2'-O",+'- o" 3'- 0",+'- O" DRY 4'- O" 5r ]" Section View 11I Digging Specs lnvert Dimensions Net Copocity Net Weight 13' Long x I' Wde 56" below inlet lnlet 0utlet Length width Height tntet Sidelouttet Totol Lid Tonk Totol 56"53"132'68"68 1002 gol lsoz oor 1509 gol 3600 lbs 11180 lbs 14780 lbs Wúr& Werbwabr o Systems o Prcducils Frgtæ5{7ol 2txþco'ru'317 P.O.Bo(æ5 Fæ (f19) gs{Jrn RsE\ßlB' @unl W$lb: wrw.wlleypmætort Ennl[ tonUælc@nlleprccastøttM¡Inc.¡serulce Residential B¡otube' Effluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranty. They prevent large solids from leaving the tank, dramatically improving waste\Mater quality and extending the life of residential drainfields. 4-in. (100-mm) Biotube Effluent Fiher 4-in. (1 00-mm) Bionbe Jr. (4-in. Biotube cartridge auail- able separateþ as Insert Fiher) f-in. (200-mm) Base Inlet Filter 4-in. (100-mm) Insert Fiher I !:ti ¡ !a li I _ti ? ! Orenco's superior effluent fhers resist clogging bener thøn all other brands. Our stan- dard, full-sized 4-in. (100-mm) Biotube Effluent Fiher prouides maximum long-term protection in a complete package, with housing. Our 4-in. (100-mm) BionbeJr., at half the size of oar standard model, has more fihering capøcity than the fall-sized fhers sold by other manufacturers. For tanþs with existing oatl¿t tees, the Biotube Insert Filter is id¿al. And for low-profile tønþs, therei the Base Inlet Fiher. * Covered by patent numbets 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu- tor, call Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator." APS-Ft-1 Rev.3.4 @ 11/10 0reneo Systems@, lnc. Standard Features & Benefits . Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satisfa ction . lnstalls in min- utes inside new or existing tanks; extendible tee handle for easy removal 0ptional Features & Benefits . Alarm available, to signal the need for cleaning . Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time . Custom and commercial sizes available . Easyto clean by simply hosing off whenever the tank needs pumping . Bemoves about two-thirds of sus- pended solids, on average. extending drainfield life . Corrosion-proof construction, to ensure long life . Lifetime warranty Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes'entire surface for filtering. Particles larger than the Biotube's mesh are prevented from leaving the tank. +*, , (lt,tnging thr lVa_y the World Ðoes Wsteuut,crn www.orenco.corr! ñ- € (lrenco Systems" lncorporaled Nomenclatures ¡l-in. Biotube Friher (standard) Frtr!04!!-!! 0ptions: Blank = no oplionsM = flow modulat¡0n plate ¡nstalledA = tloat bracket attached Carlridge height: 28" and 36" are slandard Housing height: 36" and 44" are standard Filler diameter (inches) W = fits Type 3034 outlet pipe S = fits Schedule 40 outlet pipe Blank = 1/8" filtrationP = 1/16" filtration Biotube effluent f¡lter series f-in. Biofube Fiher (base inletmodel) Ff 0822-14 B 0ptions:A = float bracket FS = 2" outlet orifice FSo = 2" outlet0rificeand overflowplale. ¿l-in. Biotube Effluent Fiher Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube@ filter cartridge Solid base Filter housing ¡l-in. Biotube Jr. Tank wall Biser wall Base inlet model Cârtridge height: 14" standard Hous¡ng height: 22" standard .Also available with coupling and sleeve as a "kit": ff-oVERFL0WKIT ¡l-in. BiotubB Jr. {includes cartridse and housing} FfJ 04 18 0ptions: Blank = no opt¡onsM = flow modulation plate installedA = lloat bracket attâched Cartridge height (inches) Filler diameter (inches) W = fitsïype 3034 oulletteeS = fits Schedule 40 oullettee Blank = 1/S"filtrationP = 1/16" filtration Junior series Biotube effluent filter series Filter diameter (inches) 08 =8" Blank = l/8" fittrationP = 1/16" filtration Biotube effluent f¡ller series Cartridge height (inches) Filter diameler (inches) Blank = 1/8" filtrationP = 1/16" filtration lnsert T -I-rt rroomized options (e.s., NC I indicates Norlh Car0lina regions) I I W = fits Type 3034 outlel teeS = fits Schedule 40 outlettee &in. Biofube Filter lnseft (cartridse onlyl FT¡04 1S -!- Biotube effluent filter series Distributed By: Item # DBox 8G Goncrete Distribution Box ({ inlet, 7 outlets) & Riser Top View Section View 1 1 Down Bafre 1 /z' Lid View End View Riser Section . 6000 PSI Concrcte. 7 Outlet equal flow. Slidejn Baffieo 4'Pipe penetration porbo Gonnectors cast into the boxo 12' Riser available Side View End View Weight: D-Box with Baffle - 200 lbs D-Box L¡d - 75 lbs D-Box Riser - 140 lbs @@@ ð ð 4.a'¿. 6 4 r )tr 4' À Á .â À WÍor& m¡t.uabr ¡ SysHne o Ploduds grq 095{zo4 2flx5ooru'fi7 P.O.BqæS Fu: (/i9')ísxigrzt Bm\frb' @81?.1 WoË¡lb: wuw.udb¡pcd.ært Ennl[ fronüæk(@tdleyprcæt otnM¡Inc.¡serulce @+.+s t11.4 cml THIS WEIR SHAPE IS SELF LEVELING THESE RIBS PROVIDE FRICTION FIT FORALL 4" PIPE ID 5.32 t13,5 cml 1.73 .09 t4.4 cml [.2 cm] 1.05 12.7 cml GEARAND RACK PROVIDES POSITIVE ONE TIME LEVELING POLYLOK EQUALIZER PART N0..3049 MATERIAL . FILLED POLYPROPYLENE IN FILTRATOR' water technologies -ou,i,ç,,t{T"' The Quick4'Plus Standard Chamber The Quick4 Plus Standard Chamber offers maximum strength through its two center structural columns. This chamber can be installed in a 36-inch-wide trench. Like the original line of Quick4 chambers, it offers advanced contouring capability with its Contour Swivel Connection'" which permits turns up to 1S-degrees, right or left. lt is also available in four-foot lengths to provide optimal installation flexibility The Quick4 Plus All-in-One 12 Endcap, and the Quick4 Periscope are availabb with this chamber, providing increased f lexibility in system conf igurations. Maximum Strength Quick4 Plus" Series Ouick4 Plus Standard Chamber Benefits: . Two center structural columns offer increased stability and superior strength . Advanced contouring connections . Latching mechanism allows for quick installation . Four-foot chamber lengths are easy to handle and install . Supports wheel loads of 16,000 lbs/axle with 12" of cover Ouick4 Plus All-in-0ne 12 Endcap Benefits: . May be used at the end of chamber row for an inleVoutlet or can be installed mid-trench . Mid-trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows . Center-feed connection allows for easy installation of serial distribution systems . Pipe connection options include sides, ends or top 0uick4 Plus All-in-One Periscope Benefits: . Allows for raised invert installations . 180" directional inletting . 12" raised invert is ideal for serial applications Certified by the lnternational Association of Plumbing and Mechanical Officials (IAPMO) \ i , Size 34"Wx53"Lx12"H (864 mm x 1346 mm x 305 mm) Effective Length 48" (1219 mm) Louver Height 8" (203 mm) Storage Gapacity 47 sat (178 L) Invert Height 0.6" (15 mm),5.3" (135 mm), 8.0" (203 mm),12.7" (323 mm) Quick4 Plus Standard Chamber Specifications APPROVED in @ 0uick4 Plus'' Series Vtti-ck4-"^ Ouick4 Plus Standard Ghamber 12" 34"48" EFFECTIVE LENGTH Quick4 Plus All-in-0ne 12 Endcap PRESSURIZED PIPE DRILL POINTS LOCATIONS (2 PLACES) 33' FRONT VIEW 18" 8'INVERT SIDE VIEW INFILTRATOR WATER TECHNOLOGIES STAI'¡DARD LIMITED WARRANTY (a) The struclural integrity of each chamber, endcap and other accessory manufactured by lnfiltrator ("Units'), when installed and operated in a leachf¡eld of an onsite septic system in accordance with lnf¡ltrator's instÍuctions, is warranted to the original purchaser ("Holdef') against defective materials and workmanship for one year from the date lhat the septic permit is issued for the septic system containing the Units; prov¡ded, however, that if a septic pem¡t is not requ¡red by applicable law, lhe wananty period will begin upon the date that installation of the septic system commences. To exerc¡se ¡ts wananty rights, Holder must notify lnfiltrator in writing at its Co/porate Headquarters in Old Saybrook, Connecticut w¡thin fifteen (15) days of the alleged defect. lnfiltrator will supply replacement Units for Units determined by lnfittrator to be covered by this Limited Wananty. lnfiltrator's liability specifically excludes the cost of removal and/or installation of the Units. (b)THE LIMITED WARRANTY AND REMEDIES lN SUBPARAGBAPH (a) ARE Ð(CLUSIVE. THERE ARE NO OTHER WARRANTIES WTH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARIICULAR PURPOSE (c) This Limited Wananty shall be void if any part of the chamber system is manufactured by anyone other than lnflltrator. The Umited Warranty does not extend to incidental, consequential, special or indirect damages. lnfiltrator shall not be liable for penalties or liquidated damages, including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incuned by the Holder or any third party. Specifìcally excluded from Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteralion, accident, misuse, abuse or neglecÌ of the Units; the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation Instructions; failure to maintain ihe minimum ground covers set forth ¡n the installation instructions; the placement of improper materials into lhe system containing the Units; failure of the Units or the septic system due io ¡mproper sit¡ng or improper sizing, excessive water usage, improper grease disposal, or improper operation; or any other event not caused by lnfiltrator. This Umited Wananty shall be void if the Holder fails to comply with all of the terms set forth in th¡s Limited Waranty. Further, in no event shall lnfiltrator be responsible for any loss or damage to the Holder, the Units, or any third party resulting from installation or shipment, or from any product liability claims of Holder or any third party. For this Um¡ted Wananty to apply, the Units must be installed in accordance w¡th all site conditions required by state and local codes; all other applicable ¡aws; and lnf¡ltrato/s installation instructions. (d) No representative of lnnltrator has the authority to change or exlend this L¡mited Wananty. No wananty applies to any party other lhan the or¡ginal Holder. The above represents the Standard Limited Warranty offered by lnf¡ltrator. A limited number of siates and counties have different wananty requirements. Any purchaser of Units should contact lnfìltrator's Corporale Headquarters in Old Saybrook, Conneclicut, prior to such purchase, to obtain a copy of the applicable wananty, and should carefully read that wananty prior to the purchase of Uniis. Quick4 Plus All-in-0ne Periscope QUICK4 PLUS ALL-IN-ONE (360'SWVEL) ls"l 12.7'INVERT 9" r IN FILTRATOR' water technologies 4 Business Park Road P.O. Box 768 Old Saybrook, CT 0ô475 860-577-7000 . Fâx 860-577-7001 1-800-221-4436 www.inll llratorwater.com Contour, MicrcLêaching, PolyTuff, Chamberspac€r, MulliPort, Pos¡Læk, Quickcut, QuickPlay, SnapLock and StraightLock are lradêmarks of lnfltrator WaterTæhnolog¡es. polyLok ¡s a trademark of PotyLok, lnc. TUF-TITE is a reg¡stered trademark of TUF-TITE, lNC. Ultra-Rib is a trademark of IPEX lnc. @ 2013 lnûltrator Wals Tæhnologies, LLC. All r¡ghts ræerved. Printed ¡n U.S.A. PLUSos 0713 Contact tnfiltrator Water Technologies' Technical Services Department for assistance at1-8OO-221-4436