Loading...
HomeMy WebLinkAboutGrand Valley Fire District Inspection Report 07.11.2019rE, cry Form: Fire Inspection Report - Start using 7-2015 Grand Valley Fire Protection District Occupancy: Dollar General Occupancy ID: 328 Address: 119 Stone Quarry RD Parachute CO 81635 Inspection Type: Certificate of Occupancy - Pre -Inspection Inspection Date: 7/11/2019 By: Jackson , Donald C (0368) Time In: 07:00 Time Out: 08:00 Authorized Date: Not Authorized By: Next Inspection Date: No Inspection Scheduled r Inspection Description: New form - Start Using 7-01-2015 Inspection Topics: Storage Storage of combustibles too close to heat source. International Fire Code, 2009 Edition - Section 315 Miscellaneous Combustible Materials Storage Status: Notes: Improper storage of combustible materials International Fire Code, 2009 Edition - Section 315 Miscellaneous Combustible Materials Storage Status: Notes: Other unsafe storage practices International Fire Code, 2009 Edition - Section 315 Miscellaneous Combustible Materials Storage Status: Notes: Disposal Other unsafe housekeeping or disposal practices intemational Fire Code, 2009 Edition - Section 304, Combustible waste material Status: Notes: Building identity Address not marked International Fire Code, 2009 Edition - Section 505 Premises Identification Status: Notes: Improper sized numbers International Fire Code, 2009 Edition - Section 505 Premises Identification Numbers shall contrast with their background, Arabic or Alphabetical Letters. Minimum of 4 inches high and minimum stroke with of 112 inch. Status: Notes: Printed on 07/11/19 at 08:20:14 Page'1 of 9: No business name on back door. International Fire Code, 2009 Edition - Section 505 Premises Identification Status: Notes: Inadequate Exit Facilities Occupancy load not posted International Fire Code, 2009 Edition - Section 1004, Occupant Load Status: Notes: Inadequate Occupancy Load International Fire Code, 2009 Edition - Section 1004, Occupancy Load Status: Notes: Exceed occupancy load International Fire Code, 2009 Edition - Seclion 1004, Occupant Load Status: Notes: Excessive travel distance International Fire Code, 2009 Edition - Section 1016, Exit Access Travel Distance Status: Notes: Dead end corridors limit International Fire Code, 2009 Edition - Section 1018.4, Dead Ends Status: Notes: Corridor obstruction International Fire Code, 2009 Edition - Section 1018.3, Corridor Obstruction Status: Notes: Aisles / corridor too narrow International Fire Code, 2009 Edition - Section 2306, General Fire Protection and Life Safety Features Status: Notes: Fire Escape Stairs International Fire Code, 2009 Edition - Section 4604.17, Fire Escape Stairs Status: Notes: Exit deficient other International Fire Code, 2009 Edition - Chapter 10, Means of Egress Status: Notes: Printed on 07/11/19 'at 08:20:14 Page 2 of 9`s Exit near unprotected hazard location International Fire Code, 2009 Edition - Chapter 10, Means of Egress Status: Notes: Exit Doors Swing direction of travel International Fire Code, 2009 Edition - Section 1008.1.2 Door Swing Status: Notes: Exit hardware International Fire Code, 2009 Edition - Section 1008.1.10, Panic and Fire exit hardware Status: Notes: Exit corridor / stairway obstructed International Fire Code, 2009 Edition - Section 1018, Corridors Status: Notes: Exit discharge door inoperable International Fire Code, 2009 Edition - Section 1027, Exit Discharge Status: Notes: Too much force to open International Fire Code, 2009 Edition - Section 1008.1.3 Door Opening force Status: Notes: Exits Not Visible Exit sign obstructed International Fire Code, 2009 Edition - Section 1030.4, Exit signs Status: Notes: Access not apparent International Fire Code, 2009 Edition - Section 1007, Accessible Means of Egress Status: Notes: Exit signs not provided International Fire Code, 2009 Edition - Section 1011 Exit Signs Status: Notes: Exit not illuminated International Fire Code, 2009 Edition - Section 1011, Exit signs Status: Notes: ft7raaMil ►AR. ori --!A Page 3 of 9 Exit signage not of approved type International Fire Code, 2009 Edition - Section 1011, Exit signs Status: Notes: Exit Unusablable Exit door locked International Fire Code, 2009 Edition - Section 1027, Exit Discharge Status: Notes: Access through locked room International Fire Code, 2009 Edition - Section 1014, Exit Acess Status: Notes: Too much force need to open exit International Fire Code, 2009 Edition - Section 1008.1.3 Door Opening force Status: Notes: Exits and Exit Stairs not maintained International Fire Code, 2009 Edition - Section 1021.1.1 Exits maintained Status: Notes: Guardrails Guardrails - 42" International Fire Code, 2009 Edition - Section 1013.2, Height Status: Notes: Handrails 34" - 38" International Fire Code, 2009 Edition - Section 1012, Handrails Status: Notes: Fire Extinguishers Not provided International Fire Code, 2009 Edition - Section 906, Portable Fire Extinguishers Status: Notes: Not Proper Type International Fire Code, 2009 Edition - Section 906.3 through 906.3.4 Status: Notes: D. .+r,rT r i f17144!4Q of f1fi•')11•44 Page 4of9 Not Charged! Inoperable International Fire Code, 2009 Edition - Section 906, Portable Fire Extinguishers Status: Notes: Not properly installed International Fire Code, 2009 Edition - Section 906, Portable Fire Extinguisher, 906.9.1 to 906.9.3 Status: Notes: Not inspected it tagged International Fire Code, 2009 Edition - Section 906, Portable Fire Extinguisher Status: Notes: Not visible / accessible International Fire Code, 2009 Edition - Section 906.6 , Unobstructed and Obscured Status: Notes: Inadequate number International Fire Code, 2009 Edition - Section 906.3, Size and Distribution Status: Notes: Fire Sprinkler l Standpipe Not maintained International Fire Code, 2009 Edition - Section 903, Automatic Sprinkler Systems and Section 905, Standpipe Systems Status: Notes: Valves not opened International Fire Code, 2009 Edition - Section 903, Automatic Sprinkler Systems and Section 905, Standpipe Systems Status: Notes: Valve accessibility International Fire Code, 2009 Edition - Section 903, Automatic Sprinkler Systems and Section 905, Standpipe Systems Status: Notes: Head Obstruction International Fire Code, 2009 Edition - Section 903, Automatic Sprinkler Systems Status: Notes: FDC - Siamese deficiency or not protected International Fire Code, 2009 Edition - Section 912, Fire Department Connects (FDC) Status: Notes: Driptorl nn A7111110 . J flft•741.1!l Sprinkler System Required International Fire Code, 2009 Edition - Section 903, Automatic Sprinkler Systems Status: Notes: Fire Alarm Alarm not provided International Fire Code, 2009 Edition - Section 907, Fire Alarm and Detection Systems Status: Notes: Not to code International Fire Code, 2009 Edition - Section 907, Fire Alarm and Detection Systems Status: Notes: System not maintained International Fire Code, 2009 Edition - Section 907, Fire Alarm and Detection Systems Status: Notes: Fire Doors and Fire Walls Self-closing Doors International Fire Code, 2009 Edition - Section 907, Fire Alarm and Detection Systems Status: Notes: Fire Door inoperative International Fire Code, 2009 Edition - Section 1025, Horizontal Exits Status: Notes: Fire Door not approved rating International Fire Code, 2009 Edition - Section 1025, Horizontal Exits Status: Notes: Corridor Rating International Fire Code, 2009 Edition - Section 903, Interior finish, decorative materials and furnishings Status: Notes: Opening in fire wall. International Fire Code, 2009 Edition - Section 703, Fire resistance rated construction Status: Notes: Unprotected vortical openings / shaft International Fire Code, 2009 Edition - Section 4603, Fire Safety Requirements for Existing buildings Status: Notes: Printed on 07/11/19 at 08:20:14 Page 6of9 Electrical Equipment Overloaded circuits International Fire Code, 2009 Edition - Section 605, Electrical Equipment, Wiring and Hazards Status: Notes: Electrical panel obstructed. International Fire Code, 2009 Edition - Section 605, Electrical Equipment, Wiring and Hazards Status: Notes: Open Panel International Fire Code, 2009 Edition - Section 605, Electrical Equipment, Wiring and Hazards Status: Notes: Wiring and distribution unsafe International Fire Code, 2009 Edition - Section 605, Electrical Equipment, Wiring and Hazards Status: Notes: Temporary wiring International Fire Code, 2009 Edition - Section 605, Electrical Equipment, Wiring and Hazards Status: Notes: Improper use of extension cords International Fire Code, 2009 Edition - Section 605, Electrical Equipment, Wiring and Hazards Status: Notes: Emergency lighting required International Fire Code, 2009 Edition - Section 1006, Means of Egress Illumination Status: Notes: Emergency Tight inoperable. International Fire Code, 2009 Edition - Section 1006, Means of Egress Illumination Status: Notes: Other electrical deficiency International Fire Code, 2009 Edition - Section 605, Electrical Equipment, Wiring and Hazards Status: Notes: Heating and Ducting Vent! Chimney! Pipe in need of repair International Fire Code, 2009 Edition - Section 603, Fuel Fired Appliances Status: Notes: .,., n'mm 4 14 0 .;f no.9n--iii Paine 7 of 9' Cooking Equipment Accumulation of grease International Fire Code, 2009 Edition - Section 609, Commercial Kitchen Hoods Status: Notes: Equipment not maintained International Flre Code, 2009 Edition - Section 609, Commercial Kitchen Hoods Status: Notes: Hood / Duct not in accordance with NFPA 61 and IFC International Fire Code, 2009 Edition - Section 609, Commercial Kitchen Hoods, Section 904.11.5 and NFPA 96 Status: Notes: Extinguishing System not to code International Fire Code, 2009 Edition - Section 904, Alternative Automatic Fire -Extinguishing Systems Status: Notes: System not certified or inspected International Fire Code, 2009 Edition - Section 609, Commercial Kitchen Hoods Status: Notes: Other cooking equipment deficiencies International Fire Code, 2009 Edition - Section 904, Altemative Automatic Fire -Extinguishing Systems Status: Notes: Miscellaneous Key Box (Knox Boxy is recommended or required International Fire Code, 2009 Edition - Section 506 Key Boxes Status: Notes: No fire lane sign International Fire Code, 2009 Edition - Appendix D, Fire Apparatus Access Roads Status: Notes: Hazardous Materials list required. (MSDS) International Fire Code, 2009 Edition - Section 407, Hazard Communication Status: Notes: General disrepair promoting fire International Fire Code, 2009 Edition - Chapter 3, General Requirements Status: Notes: n-r►+4psn .,ena•')n-4A Pane 8 of 9' Other hazard not elsewhere listed. International Fire Code, 2009 Edition Status: Notes: Additional Time Spent on Inspection: Category Notes: No Additional time recorded Start Date/Time End Date / Time Total Additional Time: 0 minutes Inspection Time: 60 minutes Total Time: 60 minutes Summary; Overall Result: Passed Inspector Notes: Inspector: Name: Jackson , Donald C Rank: Deputy Fire Chief Email(s): opschief@gvfpd.org Jackson , Donald C: Signed on: 07/11/2019 07:38 Signature Date Representative Signature: Signature Date .-. - n-rlw a !At-. _i AA.nn.A R Paan: 9 of 9