Loading...
HomeMy WebLinkAboutObservation of Excavation 08.09.2019Kumar & Associates, inc.' Geotechnical and Materials Engineers and Environmental Scientists 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Employee Owned Company www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado August 9, 2019 Rick Garnett P.O. Box 656 Idaho Springs, Colorado 80452 rick(agarnettlaw.net Subject: Dear Rick: 44° & Assodat s 3 y gemtwe www.tumamsa.cam 1489-201 Project No. 19-7-357 Observation of Excavation, Proposed Deck Piers, 8040 County Road 117, Garfield County, Colorado As requested, a representative of Kumar and Associates, Inc. observed the excavation at the subject site on June 12, August 1 and 8, 2019 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were performed in general accordance with our agreement for professional engineering services to you, dated June 3, 2019. Due to groundwater and unsuitable soils at design bearing level of 3 feet, multiple trips were needed rather than one. Twelve deck piers in 10 excavations are proposed. The piers were designed as drilled piers to be 3 feet deep and 12 or 18 -inch diameter bearing on "competent native soil" according to note 7 of the structural plans. At the time of our 2 initial visits to the site, excavation for all the piers had not been completed and several of the excavations were stopped in old fill or clay soil short of reaching the dense granular soils. When observed on August 8, the pier excavations had been completed to depths from about 3 to 6 feet below the adjacent ground surface. The soils exposed in the bottom of the excavations consisted of relatively dense, silty sandy gravel with cobbles. The results of a gradation analysis performed on a sample of the gravel (minus 3 -inch fraction) obtained from the site are presented on Figure 1. The laboratory test results are summarized in Table 1. Free water was encountered in all the pier excavations from roughly 1 to 18 inches deep. Considering the conditions exposed in the completed excavations and the nature of the proposed construction, spread footings placed on the undisturbed natural gravel soil designed for an allowable soil bearing pressure of 2,500 psf should be adequate for support of the proposed deck piers. The piers should be a minimum diameter of 18 inches. Loose disturbed soils should be removed from the pier hole bottoms before placing concrete by the tremie method to displace all the water from the bearing surface. Footings should be provided with adequate soil cover above Rick Garnett August 9, 2019 Page 2 their bearing elevations for frost protection. Backfill placed around the pier holes should be compacted and the surface graded to prevent ponding within at least 10 feet of the building. The recommendations submitted in this letter are based on our observation of the soils exposed within the pier hole excavations and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the excavated depth have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. If you have any questions or need further assistance, please call our office. Sincerely, Kumar & Associates, Inc. Steven L. Pawlak, SLP/kac Attachments: Figure 1 ''Gradation ° est Results Table 1- Summary of Laboratory Test Results Kumar & Associates, Inc. ® Project No. 19-7-357 1 1 �-e (LMT)\Drofing\1073 10 9 80 70 60 50 40 30 20 10 0 .0 HYDROMETER ANALYSIS SIEVE ANALYSIS 24 NRS 45 MIN 7 NRS 15 MIN 604IN TIME READINGS 19MIN 4MIN 1IIN 1290 U 0100 8 5. STANDARD 0 ft0 4 SERIES 0 8 6 11? CLEAR SQUARE OPENINGS /6 14 3/8" 3/4^ _—.._— - 1— -- 1— — - . _ 1 1/2" - — _ .__ 6" 8 -- — V - _— - - - - - —f- - _ _-__ _' -_ - . IJ_ - - 1- -1 1- - - _ 1_ 1- I- 1--- -1-- i -_.I--: T t r .---Y_ -T . + 1 I - L - 1 - 1 1 -- 01 .002 - 1 1- .005 1111- .009 .019 7 1 .037 1- - 11.1 11-11-1111 - 11-- 11 111li1 1 rr11-. - 17Tlrll .075 _1 4/1 DIAMETER OF PARTICLES IN MILLIMETERS 0 10 20 30 40 50 80 70 .1 76.2 12700 152 CLAY TO SILT SAND GRAVEL FINE MEDIUM COARSE FINE COARSE COBBLES GRAVEL 65 % LIQUID LIMIT SAMPLE OF: Silty Sandy Gravel SAND 27 % PLASTICITY INDEX SILT AND CLAY 8 % FROM: Bottom of Pier Hole South of House 8/8/19 0 0 00 PERCENT RETAINED These test results apply only to the samples which were tested. The testing report shall not be reproduced, except In full, wl houl the wriHen approval of Kumar & Associates, Inc. Sieve analysis testing is performed in accordance with ASTM 06913, ASTM 07928, ASTM C136 and/or ASTM D1140. 19-7-357 Kumar & Associates GRADATION TEST RESULTS Fig. 1 e 47 47 0 ® 0) =W N m in C 12 Cn cp YL N 2 c O N C le CD cv � W 111 Project No. 19-7.357 SOIL OR BEDROCK TYPE Soft, Sandy Silty Clay Silty Sandy Gravel II UNCONFINED COMPRESSIVE STRENGTH (PSF ATTERBERG LIMITS PLASTIC INDEX (%) LIQUID LIMIT (%) PERCENT PASSING NO. 200 SIEVE M VD 00 GRADATION 1 y N J g o VD NATURAL DRY DENSITY 00 NATURAL MOISTURE CONTENT (%) kr) 11 SAMPLE LOCATION BOTTOM OF EXCAVATION 08-01-2019 Close to House 3' Deep 1108-08-2019 South of House