August Sth 20II Project No. 1694
Curtis Ercanback
1015 Hickory Drive
Rifle, CO 81650
Subsurface Investigation and Onsite Wastewater System Design
Shop Construction
585 Cindy's Way
Garfield County, Colorado
Curtis,
ALL SERVICE septic, LLC performed a subsurface investigation and an onsite wastewater system
(OWS) design for the subject residence. The property is located outside of Rifle, in an area where
OV/S and wells are necessary. A shop is proposed to the north of the residence. Design parameters
will be used from our original investigation for residence.
SITE CONDITIONS
A single-family residence presently exists and a shop have several sinks, and a bathroom is proposed.
The proposed drain field area is relatively flat. Water is provided by a well which is located to the
north of the residence.
SUBSURFACE
The subsurface was investigated by digging three percolation holes, as indicated, and by digging an eight
foot test pit. Subsurface conditions consisted ofa sandy root zone underlain by siþ clayey sand to 8 feet
in depth, the maximum depth explored. Percolation rates ranged from 40 to 20 minutes per inch (MPD.
A27 I|I4PI rate will be used to clesign the OV/S.
DESIGN SPECIFICATIONS
The OWS design is based on two sinks, and a full bathroom for the proposed shop. We will consider
5 persons per day using the shop per day. The installation must include a 1000-gallon, two-
compartment, precast concrete septic tank with an effluent filter, to be followed by gravelless
chamber trenches. Two gravelless chamber trenches, using 'Quick-4' InfiltratorrM chambers OR Arc-
36 Biodifuser chambers must be installed as indicated. There must be a fotal of Each trench must
Onsite Wastewater Systems
Page2
have 1 row of 16 chambers, for a total of 474 square feet (SF) of infiltrative area. A concrete
distribution box with a baffle must be installed.
Construction must be according to the Garfield County Environmental Health Department OV/S
regulations, the OWS Construction Permit provided by the county, and this design. This design for the
subject property, noted above, is valid only in conjunction with the approved Garfield County
Environmental Health Department.
OPERATION INFORMATION AND MAINTENANCE
The surface of the drain field should be seeded upon completion. Vegetation is an important factor in
drain field performance. Erosion control should be practiced prior to and during re-vegetation. Geo-
fabrics or plastics should not be used over the drain field. No heavy equipment, machinery, or
materials should be placed on backfilled drain field. Livestock should not graze on the drain field.
Plumbing fixtures should be checked to ensure that no additional water is being discharged to OWS.
For Example, a running toilet or leaky faucet can discharge hundreds of gallons of water a day and
harm a drain field.
The homeowner should pump the septic tank every two years and clean the effluent filter as needed.
Garbage disposal use should be minimized, and non-biodegradable materials should not be placed
into the OWS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OV/S. No hazardous wastes should be directed into the OWS.
Mechanical room drains should not discharge into the OV/S. The OV/S is engineered for domestic
waste only.
ADDITIONAL CONSTRUCTION NOTES
If design includes a pump, air release valves and weep holes should be installed to allow pump lines
to drain to minimize risk of freezing. Excavation equipment must not drive in excavation of drain
field due to the potential to compact soil. Extensions should be placed on all septic tank components
to allow access to them from existing grade. Precast concrete tanks and distribution boxes should be
used, unless plastic or fiberglass is required. Access to all tank compartments and distribution devices
is optimal.
INSTALLATION OBSERVATIONS
ALL SERVICE septic, LLC, and the county must view the OWS during construction. The OWS
observation should be performed before backfill, after placement of chambers and distribution pipes.
Septic tanks, distribution devices, pumps, dosing siphons, and other plumbing, as applicable, must
also be observed. ALL SERVICE septic, LLC should be notified 48 hours in advance to observe the
installation.
Onsite Wastewater Systems
Page 3
LIMITS:
The design is based on information submitted. If soil conditions encountered are different from
conditions described in report, ALL SERVICE septic, LLC should be notified. All OWS construction
must be according to the county regulations. Requirements not specified in this report must follow
county regulations. The installer should have documented and demonstrated knowledge of the
requirements and regulations of the county in which they are working'
Please call with questions.
ALL LLC
a¿-1¿.La-
Richard H.Timothy R. Petz
3 copies sent
Pond
Pond
N
0' 50' 100'
Scale: 1" = 100'-0"
---.---_\
\E
SHED
I
SHOP
n
SHED
ı
3
!cö
0)c
=Ëoo
fL
6)c
=
o
.Eo
P-3
ooP-'t P-2
@
Drive
SITE PLAN AND PROPOSED OWS
Rtt
$t[Tr[t
P.O. Box2844
Glenwood Springs, Colorado 81602
Phone 970.618.5033
Fax 3O3.216.2796@
Ercanbrack Residence
SHOP
585 Cindy's Way
Garfield, Colorado
Project Number: 1694
w1 .0
Sheet 1 of4
2
4 BEDROOM
PR
HOUSE
N
0' ,/40'
Søale: 1" = 40'-0"
WELL
i
I
o
4" SEWER PIPE, 2% FALL TO
TANK, WITH CLEANOUT
7 1000 GAL.
TWO-COMPARTMENT TANK,
ADD EFFLUENT FILTER IN
SECOND COMPARTMENT
PROPOSED
SHOP
2 GRAVELLESS CHAMBER
TRENCHES.
QUICK 4'S = 16 TOTAL
ARC-36 = 14 TOTAL4'SDR 35 PVC PIPE
(1% FALL TO D-BOX)SHED
DISTRIBUTION BOX
OBSERVATION PIPES
POSED OWS
Rtt
$tnït[t
P.O. Box2844
Glenwood Springs, Colorado 81602
Phone 970.618.5033
Fax3O3.216.2796Étrù
Ercanbrack Residence
585 Cindy's Way
Garfield, Colorado
Project Number: 1694
w2.0
Sheet 2 of4
DESIGN
SHOP WITH 2 SINKS AND A FULL BATHROOM
5 PERSONS @ 25 GALS/DAY P-ON PVC CAP
FINISHED DO NOT GLUE
LOADING = q= 125 GALLONS PER DAY
PERCOLATION RATE = t= 27 MINUTES PER INCH (MPl)
FFLUENT
CALCULATED AREA = ((1.5 X q X sqrt t) / 5) = 195 3¡
PROPOSED AREA = 195 SF X20% REDUCTION = 156 SF
TRENCH SPECIFICATIONS
SEWER
LINE - 4'
SCHEDULE
4"
SCHEDULE INSULATED
40 P.V
4'MIN 40 0R
4'SDR
35
P.V.C.
COPPER
TRACER WIRE
MAY BE
INSTALLED TO
LOCATE LINE IN
FUTURE
WIDTH OF TRENCHES = 3 FEET = 1 CHAMBERS
LENGTH OF 'QUICK-4'TRENCHES = 24 FEET = I
CHAMBERS
TOTAL NUMBER OF'QUICK-4'CHAMBERS = 16
TOTAL NUMBER OF ARC 36 CHAMBERS = 14
TOTAL INFILTRATIVE AREA = 158 SF
SWEEP I2WAY CLEANOUT
DETATLS (N.T.S) TYP|CAL
BSERVATION
PIPE
TWO TOTAL TRENCHES
DRAIN FIELD CROSS SECTION . TYP INFILTRATOR(R) QUICK4(TM) CUT SHEET
LATERAL SUSPENDED 4" PVC OBERVATION LIMIT OF
EXCAVATION
52"
48"WITH'ZIP-TIE PIPE
1
3.0'MAX 2.s',MtN6'MIN
16"1
GRAVELLESS
CHAMBER
(a'x 3')
34',
SCARIFY SURFACE
PRIOR TO PLACEMENT
OF SAND
PVC PIPE TO ENTER IN
TOP PORT
OF END PLATE
PLAN VIEW - TYP
INLET
DISTRIBUTION BOX
WITH BAFFLE
4" PVC PIPES
SDR 35
GRAVELLESS CHAMBER
'QUICK-4'
OBSERVATION PIPE 6'
PIPE TO ENTER
CHAMBER IN TOP PORT
OF END PLATE
3'
B CHAMBERS PERTRENCH
END PLATE
24 FT
CHAMBER DETAILS
Ò
o
fltt
$t[rffi
P.O. Box 2844
Glenwood Springs, Colorado 81602
Phone 970.618.5033
Fax 303.216.2796
fs e nticìv Ercanbrack Residence
585 Cindy's Way
Garfield, Colorado
Project Number: 1694
w3.0
Sheet 3 of4
Septic Tank with the Addition of an Effluent Filter - 1000 Gallon, 2-Comp.
Concrete Risers
pe Ground
Awoy From Risers
Filter CorIridge Hondle
(field cut to desired height)
Top of tee to
1 " from lop of
come to
tcnk lid Tonk Adopter (cos[ or bolted)
Vent 0rifice
!!.nrþ¡or0"
lnlet Tee
Modulotìng Dischorge 0rifices
Voult Inlet Ports
ORENCO BRAND NAN/t
NOT INFORCED
Filter Cortridge
FfflLrenl Filter
Potents f 4,+39,323 & 5,4s2,635
Foreign Po[ents Pending
42002, Orenco Syslems, lnc.
TANK DETAIL
2"
Liquid Level
Rtt
$tRIt[t
P.A. Box2844
Glenwood Springs, Colorado 81602
Phone 970.618,5033
Fax 3O3.216.2796€¡st
Ercanbrack Residence
585 Cindy's Way
Garfield, Colorado
Project Number: 1694
w4.0
Sheet 4 of4