HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
B LR E-09-19-5933
Hunter Creek GrouP
Commercial to Residential Conversion/Remodel
16480 Highway 82, Carbondale
1,. ALL WORK SHALL COMpLy WITH THE 201s TNTERNATIONAL RES¡DENTIAL CODE (l.R.C.)AND
2009 TNTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2. IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED
,,GARFIELD COUNTY BUILDING REQUIREMENTS". NUMBERED REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3. EXISTING STRUCTURE AS PER REMODEL PLANS IS APPROVED FOR SINGLE-FAMILY
RESIDENCE USE ONLY.
4. A SEPARATE LOCK-OFF, ACCESSORY DWELLTNG UNrT (A.D.U.) OR SECONDARY DWELLING
UNIT IS NOT APPROVED AS PART OF THIS BUILDING PERMIT. ANY SUCH USE REQUIRES A
SEPARATE BUILDING PERMIT INCLUDING ALL REQUIRED FIRE-RATED ASSEMBLIES (WALLS,
FLOORS, CEtLtNGS AND/OR ROOFS) AS PER r.R.C., SECTIONS R302.3 - R302.4 FOR 2-FAMILY
DWELLINGS.
5. PROVIDE 3RD PARTY VERIFICATION OF EXISTING SEPTIC TANK CAPACITY. A SEPARATE SEPTIC
SYSTEM PERMIT MAY BE REQUIRED FOR ALTERATION OF THE EXISTING SEPTIC SYSTEM IF
NUMBER OF BEDROOMS EXCEEDS CAPACITY OF EXISTING SEPTIC TANK.
6. INSULATION AT THERMAL ENVELOPE SHALL COMPLY WITH 2OO9 I.E.C.C. MINIMUM
REQUIREMENTS.
7. ELECTRICAL PERMITT¡NG AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL FINAL
APPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.