Loading...
HomeMy WebLinkAbout1.0 ApplicationCommunity Development Department 108 8th Street, Suite 401 Glenwood Springs, CO 81601 (970)945-8212 www.garfield-county.com SMALL TEMPORARY EMPLOYEE HOUSING APPLICATION FORM This Application form must be completed and received by the Garfield County Community Development Department within 48 hours following occupancy of the Small Facility. In addition, documents shall be provided to the Sherriff’s Office and relevant fire protection district(s) that demonstrate and certify compliance with the following standards. Notice shall also be provided to these entities within 48-hours following removal of a Small Facility. It is the Operator’s responsibility to confirm and obtain verification that this Application has been received by the Sheriff’s Office and Fire Protection District. INVOLVED PARTIES Property Owner Name: ____________________________________ Phone: (______)_______________ Mailing Address: ______________________________________________________________________ City: _______________________________________ State: _______ Zip Code: ____________________ E-mail:_______________________________________________________________________________ Operator’s Compliance Officer Name: ________________________________________________ Phone: (______)_________________ Mailing Address: ______________________________________________________________________ City: _______________________________________ State: _______ Zip Code: ____________________ E-mail:_______________________________________________________________________________ PROJECT NAME AND LOCATION Location of Housing Site (Section/Township/Range): S____________ T____________ R___________ Well Pad Number: _________________________ Assessor’s Parcel Number: __________________ Zone District: _____________ Maximum Number of Permitted Occupants: ______________________ Number of Days the Facility will be at Location: ____________________ State or Federal Permitting Agency Overseeing Reclamation, Restoration and Revegetation (Name): (Name): __________________ (Relevant Permit Number): ___________________________________ Date of Installation: ___________________ Date of Removal: _______________________ 24-Hour Emergency Contact (1): ______________________________ Phone Number: _______________ 24-Hour Emergency Contact (2): ______________________________ Phone Number: _______________ ELIGBILITY During times of housing shortage or in remote locations, the use of Factory Built Nonresidential Structures (as defined under C.R.S. § 24-32-3301, as amended, and Resolution #35 of the Colorado State Housing Board) utilized for a period of time not longer than 1 year or as otherwise specified, for workers who are engaged in commercial, industrial, mineral extraction, or highway operations and who are needed to support the proper execution and safety of the related operations. Temporary Employee Housing, shall not include Recreational Vehicles, except in a Small Facility. A Small Temporary Housing Facility shall have all of the following basic characteristics: Complies Y/N 1. The Small Facility and any associated infrastructure must be completely contained within a State or Federally-permitted parcel (such as a COGCC- approved oil/gas well pad) in which reclamation and revegetation are secured with the permitting agency (Permitted Site); and 2. The Small Facility is located at the Permitted Site for less than a cumulative of 1 year and at the end of the utilization period, all structures, foundations, and associated infrastructure are completely removed; and 3. The Small Facility shall have an occupancy of 8 or fewer people who are employees, contractors, or subcontractors of the operator of the small facility and are needed for on-site safety of the related commercial, industrial, extraction, or highway operation. SUBMITTAL REQUIREMENTS. The application submitted to the County shall contain the following information: 1. A vicinity map indicating the section, township, and range of the subject lot and the location of Small Facility within the subject lot and the Permitted Site; general relation to surrounding public roads, private roads, adjacent utility systems, residential development, other actively permitted Small, Minor and Major Facilities, natural drainage courses and municipalities within one (1) mile of the proposed Small Facility; north arrow and scale; GPS coordinates and current surface ownership of the subject lot. The vicinity map shall be presented on a USGS 7.5 minute series quadrangle at a scale of 1”=2000’ or equivalent, with a topography depicted at a minimum of 40’ intervals. 2. Surveyed layout of the proposed Small Facility within the surveyed boundaries of the Permitted Site, including at a minimum: sewage and wastewater disposal, trash receptacles, potable water storage, all other associated infrastructure and all other equipment located within the Permitted Site. 3. Identification of the private and public roadways accessing each Small Facility. Roadways shall be marked as open, gated, and/or locked (include combinations). Detailed directions, with mileage, shall be given from the nearest town within Garfield County, nearest Garfield County Sheriff’s Office dispatch location and responsible fire district headquarters to each Small Facility, along each roadway. STANDARDS 1. Small Facilities shall comply with all applicable Federal, State (i.e. Building Codes and electrical permits), and local laws and regulations (i.e. fire code), but are not subject to County Building Permit. 2. Water Systems. a. Water systems shall comply with standards set forth in section 7-705.B. Water systems must comply with all applicable State and local laws and regulations. b. All potable water systems must include a meter and the Operator must keep a record of the daily usage. c. For sites to which potable water is hauled, Operators shall: i. Keep appropriate records, to be provided to the County upon request, to demonstrate that water supplied to a site is from an approved source and that wastewater is disposed at an approved facility. ii. For water facilities not permitted by the CDPHE, the Operator must conduct monthly tests (or quarterly if an on-site disinfection system is installed) and maintain records of potable water samples specific for coli form. Any tests indicating coli form contamination must be disclosed to the County Public Health Department. iii. Water systems facilities permitted by the CDPHE must obtain all necessary State permits or demonstrate that applications for any necessary permits have been submitted prior to a determination by the County that an application is complete. iv. Maintain compliance with State regulations at all times during operation. d. In no case shall unsafe water be used for drinking nor shall raw sewage or used water be discharged onto the ground surface. 3. Wastewater Systems. a. Wastewater systems shall comply with standards set forth in section 7-705.C. Wastewater systems must comply with all applicable State and local laws and regulations. b. Wastewater may be disposed of using either an OWTS or a vault-and-haul system. A vault- and-haul system must demonstrate the following: i. Year-round access is available and maintained for safe and regular access for sewage hauling vehicles; ii. The Operator can demonstrate and guarantee an arrangement for hauling sewage; iii. The Operator will maintain all records, including but not limited to, trip logs/reports and landfill receipts; iv. The sewage disposal records will be maintained as public records to be available to the County upon request; v. The facility will not exceed a cumulative of 1 year at the approved location; and 4. The facility has been designed to accommodate 75 gallons of wastewater per person per day or an amount derived from engineered calculations taken from metered usage rates at a similar facility that has been reviewed and approved by the County. 5. Each Small Facility shall be maintained in a clean, safe, and sanitary condition, free of weeds and refuse. Any hazardous or noxious materials that must be stored at the Small Facility for operational or security reasons must be managed in accordance with all applicable Federal, State, and local laws and regulations. 6. Wildlife-proof refuse containers must be provided for trash. Outdoor food storage is prohibited unless facilities are provided that prevent the attraction of animals to the Major Facility site. 7. Fire Protection and Suppression. a. Provisions for giving alarm in case of fire and fire suppression must be installed per fire codes and as required by the fire protection district. b. Single-station carbon monoxide alarms must be placed in each Manufactured Home or Recreational Vehicle unit. c. A water storage tank is required to provide water to the sprinkler system (if applicable) and initial suppression activities. The size of the water tank shall be determined based on sprinkler calculations and initial suppression demands. The relevant fire protection district shall be responsible for determining the size of the water storage tank. If the Small Facility is not within a fire protection district, the Operator shall provide at least 2500 gallons of water dedicated to initial fire suppression which is accessible with a dry hydrant. Required Size of water storage tank for sprinkler system and initial suppression activities: ________________________ gallons 8. Domestic animals are prohibited. 9. The Operator shall obtain a certification inspection conducted by a qualified professional engineer. The certification shall verify that at the time of inspection the identified Small Facility meets or exceeds the requirements of this section. Fox Engineering Solutions, Inc. P.O. Box 413, Fruita CO 81521 Ph: (970) 250-5505 Email: coloradofox@bresnan.net Inspection Report for: GV 1-8 Well Pad - Small Temporary Employee Housing Prepare for: Terra Energy Partners Location: NE1/4 SW1/4 of Section 8, T7S, R96W, 6th P.M. Garfield County Conducted By: David Fox, P.E. Date Conducted: October 4, 2019 Garfield County Paragraph Article 7-707 Land Use& Development Code (7/15/13) Reference Characteristic or Standard Description Inspection Comments A.Within 48 hours following occupation of the Small Facility, documentation shall be provided to the Community Development Department, Sheriff’s Office, and relevant fire protection district(s) that demonstrates and certifies compliance with the following standards. Notice shall also be provided to these entities within 48-hours following removal of a Small Facility. Not subject to visual inspection and certification by third party Professional Engineer. B.General Information reguirements Not subject to visual inspection and certification by third party Professional Engineer. C.Small Facilities shall comply with all applicable Federal, State (i.e. Building Codes and electrical permits), and local laws and regulations (i.e. fire code), but are not subject to County Building Permit. Colorado Division of Housing certifications noted on Company Office trailer, Unit ID. AJGO-1457-3763 with Certification No. 18921 manufactured by Advanced Modular Mfg. in 2007; Company trailer, Unit ID D1460120005 with Certification No. 25364 manufactured by PTI Group USA in 2012; Driller's trailer, Unit ID. 30-3319 with Certification No. 20534, manufactured by Ameritech Buildings in 2008; Directional trailer, Unit ID AAJU-1465- 4185 with Certification No. 23718 manufactured by Advanced Modular in 2010; and Mud Engineer trailer, Unit ID AABU-1465- 4531 with Certification No. 24893 , manufactured by Advanced Modular Mfg. in 2012. All other aspects not subject to visual inspection and certification by third party Professional Engineer. D Water systems shall comply with standards set forth in section 7-705.B. The water system at this location is not a public water system, as defined by the Colorado Department of Public Health & Environment - WQCC Regulation No. 11. It is not subject to State permitting requirements. Two potable water tanks with a capacity of approximately 3360 gallon each and equipped with water meters were located at the permitted site. Page 1 of 3 GV 1-8 Well Pad Inspection Terra Energy Partners Fox Engineering Solutions, Inc. October 4, 2019 E.Wastewater systems shall comply with standards set forth in section 7-705.C. Wastewater disposal at the permitted site will be a vault-and-haul system. Five 1500-gallon sewage holding tanks onsite. Sewage flows estimated to be 300 gallons/day (4 individuals x 75 gpcd). Sewage holding tanks need to be emptied approximately every 25 days (7500 gallons / 300 gallons per day). Wastewater vaults equipped with overflow alarm device. F.Each Small Facility shall be maintained in a clean, safe, and sanitary condition, free of weeds and refuse. Any hazardous or noxious materials that must be stored at the Small Facility for operational or security reasons must be managed in accordance with all applicable Federal, State, and local laws and regulations. Site appeared to be maintained in clean, safe and sanitary condition, free of weeds and refuse. G.Wildlife-proof refuse containers must be provided for trash. Outdoor food storage is prohibited unless facilities are provided that prevent the attraction of animals to the Major Facility site. One wildlife-proof trash recepacle with a capacity of approximately 20 cubic yards each onsite. Individual refuse containers in each office/housing structure. H.1 Provisions for giving alarm in case of fire and fire suppression must be installed per fire codes and as required by the fire protection district. Smoke detectors and fire extinguishers (ABC-rated) located in all factory built non-residential structures. Mancamp living quarters trailers have a minimum separation distance of 20 ft. Approximately 10,000 gallons of water is stored onsite for fire suppression activities. Required fire suppression demand is 2500 gallons. Water meters and dry hydrant connections observed on water tanks. H.2 Single-station carbon monoxide alarms must be placed in each Manufactured Home or Recreational Vehicle unit. Single-station carbon monoxide detectors located in all factory built non-residential structures I.Domestic animals are prohibited. No domestic animals observed on-site. J.The Operator shall obtain a certification inspection conducted by a qualified professional engineer. The certification shall verify that at the time of inspection the identified Small Facility meets or exceeds the requirements of this section. This inspection was conducted by a qualified Professional Engineer licensed in Colorado and certifies compliance with applicable standards set forth in Article 7.707 of the Land Use and Development Code (7/15/13), as amended, that are subject to visual inspection. Page 2 of 3 GV 1-8 Well Pad Inspection Terra Energy Partners Fox Engineering Solutions, Inc. October 4, 2019 Professional Engineer's Attestation PE Certification Number: No. 25420 (Colorado)PE Stamp Date of Inspection: October 4, 2019 Print Name and Title: David J. Fox, Principal Engineer Signature: I hereby attest that I am a Licensed Professional Engineer in the State of Colorado. I attest that I or my agent have conducted a visual inspection of the Small Facility identified in this Checklist, as installed, and, based on information from that inspection I certify that the Small Facility complies with the standards, subject to and limited to visual inspections items as identified above; set forth in Article 7-707 of the Land Use& Development Code (Effective 7/15/13), for Garfield County, Colorado. Page 3 of 3 TEP Rocky Mountain LLC 1058 County Road 215 P.O. Box 370 Parachute, Colorado 81635 (970) 285-9377 October 7, 2019 Garfield County Sheriff’s Office Emergency Operations Attn: Chris Bornholdt 107 8th Street Glenwood Springs, CO 81601 Ph: 970-945-0453 RE: Emergency Response Notification GV 1-8 pad (Lat.: 39.450677 Long.: -108.132747) This notification is to inform the Garfield County Sheriff’s Office that TEP Rocky Mountain LLC has commenced drilling operations on the above mentioned location. TEP will provide rig site housing accommodations for the duration of the operations which will be approximately 50 days. In accordance with Garfield County Community Development we must notify you of the small temporary employee housing onsite. Please see the provided emergency response information, site layout and directions to location. Should you have any questions or concerns regarding this notification please feel free to contact me. Sincerely, Kaylee McIntosh | Engineering Technician | TEP Rocky Mountain LLC | 1058 County Road 215 | Parachute, CO 81635  (Office) 970.263.2731 |  (Mobile) 970.623.9452 |  kmcintosh@terraep.com TEP Rocky Mountain LLC 1058 County Road 215 P.O. Box 370 Parachute, Colorado 81635 (970) 285-9377 October 7, 2019 Grand Valley Fire Protection District Emergency Operations Attn: Deputy Fire Chief 0124 Stone Quarry Rd Parachute, CO 81635 Ph: 970-285-9119 RE: Emergency Response Notification GV 1-8 pad (Lat.: 39.450677 Long.: -108.132747) This notification is to inform the Grand Valley Fire Protection District that TEP Rocky Mountain LLC has commenced drilling operations on the above mentioned location. TEP will provide rig site housing accommodations for the duration of the operations which will be approximately 50 days. In accordance with Garfield County Community Development we must notify you of the small temporary employee housing onsite. Please see the provided emergency response information, site layout and directions to location. Should you have any questions or concerns regarding this notification please feel free to contact me. Sincerely, Kaylee McIntosh | Engineering Technician | TEP Rocky Mountain LLC | 1058 County Road 215 | Parachute, CO 81635  (Office) 970.263.2731 |  (Mobile) 970.623.9452 |  kmcintosh@terraep.com