Loading...
HomeMy WebLinkAboutSpecial Inspection Report 06.27.201207-05-12;14:26 ;Tally Ho Construction 3843470 ;9706258636 # 2/ 2 West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone: 970-434-6988 Cell: 970-260-2844 JUL 0 5 2012 NhLLU L;U(JNTY 1!NP , . pL4I\iNNG Report #1 Page 1 of 1 Inspection Report Date: 6-27-12 Project: Fuel Station Canopy Swallow Oil Co. Address: 69 County Rd. 264 Rifle, CO Building Permit No.: BLCO-5-12-2480 General Contractor: Tally Ho Construction & others Inspection of shop fabrication or field work at ,fob site: Field - - Report: Visually inspected the A325 high strength bolting at fuel canopy steel frame connections. Also randomly tested some of the bolts for proper tightness. Visually inspected completed welding at main support column splice welds & received a copy of welder qualification for welder that performed work. Note no in process inspection was performed on these welds just an inspection of the completed weld passes. The high strength bolting & field welding inspected as outlined above appeared to be in substantial conformance with the plans, and the quality requirements of the AWS D1.1 Structural Welding Code & the AISC/RCSC Specifications for high strength bolting. To the best of my knowledge this completes the special inspections of the high strength bolting & field welding on the project as outlined above. Inspectorrfechnician: Douglas E Young o asE C r%o t Q 'EXP. 711