Loading...
HomeMy WebLinkAboutEngineer Report 05.14.19Mnrnr ButtDINc ourlEr coRP. Metal Building Outlet 10390 Bradford Road Suite 140 Littleton, CO 80127 MBO S.O NO,10743-RA END-USER: Cattle Creek Millwork JOBSITE: 252CR167 GLENWOOD SPRINGS, CO 81601 COUNTY: GARFIELD BUILDING END USE:SHOP To whom it may concern: Metal Building Outlet Corp, LLC, certifies that the above structures were designed in accordance with theA./.S.C. Specification for Structural Sfee/ Buildings - Allowable Strength Design, ANSUAISC 360-10, the A.l.S.l. Standard, Noñh American Specification for Design of Cold-Formed Sfee/ Structural Members,Sl00-2012 5110-07 , A.W.S. Dî.1-201 D1.3-1998 D1.4-2011 StructuratWetding Code - Sheef Sfeel and generally accepted engineering practices.Loads applied design the building/s are no less than the requirements prescribed in the order document and the design satisfies the requirements of the 2015 lnternational Building Code. (Refer to Building Description and Design Loads on succeeding pages) Accessories provided by others are to sustain the design wind load. Likewise, the customer is to ensure that the above comply with the requirements of local regulatory authorities. Open web joists, if used and supplied by MBO shall be from a SteelJoist Institute (SJl) approved manuacturer. This Letter of Certification covers only the design of the steel building and its components. lt specifically excludes accessories, anchor bolts, foundation, masonry, or general contract work as well as erection certification. Sincerely, 5t14t2019 Frederick J. Campana Professional Engineer Page 1 of3 Continuatlon oI MBO S.O. trtO.; A BUILDING DESCRIPTION BUILDING FRAME TYPE WDTH (ft) LENGTH (ft) EAVE HETGHT BACK SIDEWALL (ft) EAVE HETGHT FRONT SIDEWALL (ft) ROOF SLOPE BACK SIDEWALL (ft) ROOF SLOPE FRONT S¡DEWALL (ft) BAY SPACING FROM LEFT TO RIGHT (ft) A B 60 120 19 19 4,0:12 4.0:12 5@24 2 55 33 14 14 2'.12 2:12 @ 16'6" LOADS DESIGN CODE ENCLOSURE DEAD LOAD (psf) COLLATERAL LOAD (Psfl WND LOAD Ultimate Wind Speed (mPh) \Mnd lmportance Factor, lw Wind Exposure lnternal Pressure Coefficient, GCPi LIVE LOAD Primary Framing (psf) Tributary Area Reduction Secondary Framing (Psf) SNOW LOAD Ground Snow Load, PS (Psfl RoofSnowLoad, Pf(psf) Sloped Roof Snow Load, Ps (Psf) Snow Exposure Factor, Ce Snow lmportance Factor, ls ThermalFactor, Ct Slope Factor, Cs SEISMIC LOAD Seismic lmportance Factor, le Seismic Occupancy Category Site Class Mapped Spectral Response Acceleration Spectral Response Coefficient Seismic Design Category, SDC Basic Force Resisting Systems Used Total Design Base Shear, V (kiPs) Response Modification Factors, R Seismic Response Coefficients, Cs Analysis Procedure Used RAINFALL INTENSIW (inches/hr) tBc 15 c Building Structure Only 3 115 1 c 0.18 -0.18 20 No 20 60 60 60 1 1 1 1 1 1t D Ss= 0.33 51= 0.083 Sds= 0.338 Sd1= 0.133 c Steel System Not Detailed For Seismic Resistance Rigid Frames & Braced Frames 13.1 Rigid Frames = 3.5 End Wall x Bracing = $ Side Wallx Bracing = $ Rigid Frames = 0.097 End Wallx Bracing = 0.068 Side Wallx Bracing = 0.097 Equivalent Lateral Force Procedure 11= 4 12=6 Page 2 of 3 Continuation of MBO S.O. ilO.; A DEFLECTION LIMITS EndwallColumn Endwall Rafter Live Endwall Rafter Wind WallGirt Purlin Live 180 180 180 90 180 120 120 180 120 60 Purlin \Àlind WallPanel Roof Panel Live Roof Panel\Mnd Rigid Frame Horizontal Rigid Frame Vertical Wind Bent Rigid Frame Crane Rigid Frame Seismic Wind Bent Seismic 180 60 100 50 50 Page 3 of 3