HomeMy WebLinkAboutEngineer Report - Framing 11.28.18Ernest Kollar nsineers. fnc. 320 Main St., Suite 203 Carbondale, CO 81623 Phone (970) 963-3223 erniekollar@gmail.com November 28,2018 To: B.J. Schmidt Hayes Construction Re Orchard Creek Ranch 156 CR 137 Garfield County, CO B.J At the request of the building department, I performed a final framing walk-thru on October 12,2018. Framing was complete; windows were installed; the exterior guard rails had not yet been installed. Prior to the visit, on August 2,2018,I performed a similar site visit and requested that several improvements be made. The list included additional blocking, hangers, clips, and shear walls, as well as improvements to some of the joist and beam bearing conditions. During the October l2th visit, I confirmed that these items were completed. The structure appears to have been constructed in conformance with the structural drawings and my intent. Please call with any questions, êncst, Kollat Ernest Kollar, PE a WEST VALLEY INSULATTOH INSULATION CERTIFICATE INSTALLED INSULATION R-57 Flybrid (5.5 inches) R-38 of polyurethane spray foam with R-l9 unfaced batt underneath to all flat ceiling area R-57 Hybred (5.5 inches) R-38 polyurethane spray foam with R-19 unfaced batt underneath to all garage ceiling areas R-21 (3.0 inches) of polyurethane spray foam to all 2x6 exterior walls of house and garage R-13 unfaced batt insulation with membrain to all fured concrete walls of basement and garage, R- 19 unfaced batt to extende d 2x4 (touch walls) R-21 (3.0 inches) of polyurethane spray foam to all rims and box sills R-30 unfaced batt insulation to all midfloor joists R-38 unfaced batt insulation to all crawl spaçe ceiling joists with rod hangers R-19 unfaced batt insulation mechanically fastened to crawl space walls R-19 unfaced batt insulation to all 2x6 interior walls R-21 unfuced batt insulation to garages common walls Foam all penetrations doors and windows Insulation Manager Steve Neff 970-986-t664 November 2A,2018 To: Hayes Construction Job Address: 157 County Road 137 Garfield County Building Department Glenwood Springs, CO 81601 PHoNE {970) 876-40û4 (97s) 876-4091 Et"r$L Palicom*20ffi@yahoo.com 150 W l4ain Street s¡lt, co 8165tffi WEST SLOPE TESTING & INSPECTION LLC 3177 Glendam Dr Grand Junction, CO 81504 Phone: 970'434'6988 Cell: 970-260-2844 6-26-18 Page 1 of 1 Garfîeld County Building Inspection Dept. l08 8th St., Suite 4ol Glenwood Springs, CO 81601 Please find enclosed special inspection progress reports for Ensign residence & Orchard Creek Ranch project. Thank You; Doug Young West Slope Testing & Inspection LLC 3177 Glendam Dr' Grand Junction, CO 81504 Phone: 970-434'6988 Cell: 970-260-2844 Report #1 Page 1 of 1 I n ort tes:'I Project: Ensign Residence Address: 683 Overlook Dr. Garfield County, CO Building Permit No: BLRE-08-1 7-4868 General Contractor: Thunder Construction Contractor that Performed Work: Sopris Steel fabrication or field work at ob site: -18 of Report:Visually inspected at beams & columns plece lcl,3c2, 5C2, 5:C3, 5C4, 6Cr,6C2, 6C3, 6C4, 7 Cl, 7 C2, 7 C3, 9B 1, 982, 983, 1081, 10F.2,1083, and 1181. Thewelding inspected above appeared to be in substantial conformance with the plans, and the quuiity r.q,.rirements of the AWS D1.1 Structural \Melding Code'' Further inspections shóuld be performed, as work progresses on the project' DouglasE.Young Certifrcation #sr02224 fnspector/Technician: Douglas E Young &Inspector lnspector Ðouglas F Youngcwt 96070131 QCl EXP. 7!1t2t20