Loading...
HomeMy WebLinkAboutAs-built Site PlanG:\2018\18027\CIVIL\CIVIL DWGS\DE\18027-AC-OWTS-.DWG - Nov 29, 2019 - 9:57am - \ S OPRIS ENGINEERING, LLC. \ 3.0% CIVIL CONSULTANTS - _ - - - - - - - \ SINGLE FAMILY HOME FFE: 5597.5' GENERAL NOTES: 1. THE OWTS AS SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY SOPRIS ENGINEERING. 502 MAIN STREET CA 502 MAI LE, CO 81623 (970) 704-0311 FAX: (970)-704-0313 \ ;: 2. THE PROPOSED LOT CONDITIONS BY: SOPRIS ENGINEERING. FG:55 6.50' 3. SURVEY INFORMATION PREPARED BY: SURVEY CO. INC. 5596 4. PRIMARY OWNER NAME AND ADDRESS: BRIAN & MICHELLE KLEIN, \ 1543 BEECH STREET, RIFLE, CO, 8165 \ - - 5. Legal Summary Quarter: 5 TOWNSHIP: 6 RANGE: 91 SUBDIVISION: CCP SUBDIVISION BLOCK: 1 LOT: 1 AS PER PLAT RECEPTION NUMBER 890332 \ \ ` 3 _ 4. SITE ADDRESS: 209 COUNTY ROAD 263, NEW CASTLE, , COLORADO /s 3.0% / 5. PARCEL #: 218105101295 '5I �11 .}i\S 17N .1/c5".`uv\ SAS IM - OAS I - \ 2+60 2+00 6. GARFIELD COUNTY PERMIT #: SEPT -06-19-5819 , ISSUED 7/23/2019 - - ZN 7. CONTRACTOR: JOSE GONZALES, CALIBER CONSTRUCTION, 1196 E 17TH STREET, RIFLE, CO 81650, 970-314-0489 DESIGNED BY PR 03/07/18 0 _ • _ e• / / DRAWN BY PER 11/27/19 3 4°/ OWTS OPERATION AND MAINTENANCE / RESPONSIBILITY FOR MAINTENANCE AND REPAIR OF THE INSTALLED OWTS WILL REMAIN WITH CHECKED BY PR 11/27/19 3 BEDROOM SINGLE FAMILY HOME c,� R10.00' / THE PROPERTY OWNER. THE OWNER IS ENCOURAGED TO RETAIN THE SERVICES OF QUALIFIED PERSONNEL TO INSPECT THE OWTS AND TO PERFORM ALL MAINTENANCE AND REPAIRS DATE: 11-27 19 / NECESSARY TO ENSURE THAT THE SYSTEM COMPONENTS ARE MAINTAINED IN GOOD JOB NO. 0FG:5.96.50' 55 OPERATING CONDITION AND SUITABLE VEGETATIVE COVER IS ESTABLISHED ON THE FIELDS. 18027 THE COMPONENTS OF THE OWTS SYSTEM SHOULD INSPECTED WITHIN 30 DAYS OF BEING SSgO -\ X5596 / PLACED INTO OPERATION AND SHOULD BEEN INSPECTED AND MAINTAINED BI -ANNUALLY. THE / TANK, ABSORPTION FIELD AND OTHER SYSTEM COMPONENTS SHOULD BE VISUALLY INSPECTED BI -ANNUALLY FOR DEBRIS, DAMAGE, LEAKS, OR OTHER POTENTIAL PROBLEMS. IN GENERAL, �� -5595 / FOR A PROPERLY UTILIZED SYSTEM, SEPTIC TANKS SHOULD BE PUMPED EVERY 3 - 5YEARS. THE EFFLUENT FILTER SHOULD BE CLEANED EVERY SIX MONTHS AND AT THE TIME OF PUMPING. INSTALLED 4" 2 -WAY CLEANOUT ABSORPTION FIELDS SHOULD BE MAINTAINED WITH SUITABLE VEGETATIVE COVER AND KEPT FREE OF ROOT INVASIVE PLANTS. POSITIVE SURFACE DRAINAGE AWAY FROM THE ABSORPTION FIELD SHOULD BE MAINTAINED. Klein -Design Calculations OWTS KLEIN PROPERTY 209 COUNTY ROAD 263, NEW CASTLE, COLORADO ONSITE WASTEWATER TREATMENT SYSTEM PLAN GARFIELD COUNTY, COLORADO AS -CONSTRUCTED OWTS RECORD DRAWING - - INSTALLED A 2 -COMPARTMENT 1250 -GALLON CONCRETE SEPTIC TANK ( VALLEY PRECAST ITEM-1250T-2CP-EF), INSTALL WITH (2) 24" DIA. BY 12" DEEP CONCRETE RISERS WITH LIDS AT THE SURFACE. 4" PVC GRAVITY SEWER LINE. BED W/ CLASS -6 AT 2% SLOPE± The design flow is calculated as follows for a 1700 S.F. three bed -bedroom residentce. The onsite wastewater treatment system (OWTS) is designed for a 3 -bedroom residencial capacity. From the Regulation 43 usage table : Minimum population based on 3 bedrooms = 6 persons. Gallons per day per person =75 gal/person/day, No peaking factor Max. Design flow (Qd)gallons/day = (# of people) x (avg. flow)gal/person/day. Design flow Qd = 6*75=450 gpd Septic Tank Design: INSTALLED INLET SANITARY TEE AND OUTLET EFFLUENT FILTER SANITARY TEE. DEPTH TO TOP OF TANK FROM EXISTING GRADE IS APPROXIMATELY 24 INCHES. TOP RISER LID @ FINISH GRADE Use a 1250 gallon, two compartment concrete septic tank with an effluent filter outlet sanitary tee in the second chamber. Tank shall be installed with sealed concrete risers and lids to the finish grade surface. Sub Surface Conditions and Testing: INSTALLED ABSORPTION/TREATMENT FIELD INSTALLED 54 QUICK -4 CHAMBERS IN 3 TRENCHES WITH 18 CHAMBERS PER ROW FOR A N TOTAL ABSORPTION AREA OF 630 S.F. THE SYSTEM IS PLUMBED FOR EQUAL GRAVITY \ Subsurface soil investigations and USDA soil texture method tests were performed by Sopris Engineering on March 7, 2018. The soils in the development envelope were sampled and DISTRIBUTION. THE CHAMBERS ARE INSTALLED ON LEVEL GRADE IN EACH TRENCH. THE BOTTOM OF EACH TRENCH WAS EXCAVATED TO A MAXIMUM DEPTH OF 36 INCHES \ BELOW THE EXISTING SURFACE GRADES, WITHIN THE NATIVE SILT LOAM SOILS & BACKFILLED WITH A MINIMUM 12 INCHES OF COVER OVER THE CHAMBERS. THE FINISH GRADE ACROSS THE FIELD IS SLIGHTLY MOUNDED ABOVE EXISTING ADJACENT GRADES. ® characterized by application of the USDA soil texture method analysis. The soils were tested to determine the hydraulic loading rate and the appropriate absorptive surface depth for a soil treatment unit (STU). An eight foot deep excavated profile pit and three shallow excavations were observed in the south central portion of the site. The soils below 6 to 12 inches of topsoil \ ® I consist of moderately dense sandy silt loam with moderate granular to fine grained structure with scattered gravel and cobbles to a depth of 5 feet overlying sandy clayey loam to the 8 foot depth explored. The soil appears to be consistent across the site. 4" RISER PIPE INSPECTION PORT INSTALLED \ AT EACH END CHAMBER (TYP.) 4" PVC DISTRIBUTION PITYP.) P o / / \ / \ \\ / / / The native soils sampled from 1-3 feet below the surface are characterized as a soil type 2A consisting of silt loam texture with moderate granular structure to fine grained at 5 foot depth. This soil has an effective loading rate for conventional soil treatment of 0.50 gal/S.F./day for a level 1 conventional treatment system. The equivalent percolation rate is approximately 26-40 minutes per inch. Increased quantities of cobbles and gravel are encountered at depths between 3 and 4 feet. No free water was encountered in excavations on site. Groundwater levels are expected to be well below 10 feet from the existing surface grades. The soils appear suitable for a conventional shallow absorption field consisting of gravelless infiltration chamber units.. 7 Treatment -Soil Treatment Unit/Absorption System Design: Z o ------------- 21.00' o ------------------- 0-----.10: ° CONCRETE DISTRIBUTION BOX WITH INSTALLED LEVEL ON COMPACTED INSTALL RISERS AND LID TO SURFACE / - - \ Z Z 7 BAFFLE \ BASE \ \ 114.91' \ - The treatment/absorption field is designed based on utilizing the effective Long Term / Acceptance Rate (LIAR) for the native soils and the application of appropriate loading factors for a soil treatment unit system utilizing gravity distribution to gravelless chamber trenches and use of water saving fixtures. The new treatment system and absorption field will consist of gravity distribution of septic tank effluent via a distribution box to individual chamber trenches with treatment across the native soil absorptive surface. Long Term Acceptance Rate (LTAR) Considering the application of the new state regulation 43: Receiving Wastewater Treatment Level 1; loading rate for silt loam is (0.50 gal./S.F./day) for soil type 2A.; Loading factors; (Table 10-2, Gravity application trenches = 1.0) and (Table 10-3, gravelless chambers = 0.7) ° \ \ A(sf) = Qd .: A = Area; \74.00' \ - \ \ LTAR LTAR = 0.50 Gal/S.F./day for silt loam Qd = flow (gal/day) = 450 gpd EXCAVATION DEPTH APPROX,L. 1.5'-3' BELOW EXISTING GRADE CHAMBER END CAPS INSTALLED ON \ \1250 Item # Gallon Top Seam - 2CP F.1=1.0 GravityDistribution L.F.2=0.7 Chambers A(sf) = 450 gpd x 1.0 x 0.7 = 630 S.F. 1250T-2CP 0.50 Gal/S. F./day \ THE ENDS OF ALL CHAMBERS N 27.63' \ \ View W Number of quick -4 chambers: 630S.F = 50 chambers Use 54 chambers \ 135" DESIGN NOTES -" N. \ Design per performance test per C1227 • Top surface area 56.25 ft' • fc ®28 days; concrete = 6,000 Min. Installation: ASTM PSI JJ '. / �'. jj - I Use 54 Quick -4 chambers in three trenches 74' long by 3' wide with 18 chambers units per trench plus two end caps as delineated on the plan. The septic tank effluent will be gravity distributed to the head of each chamber row via individual distribution pipes from a distribution box. Additional soil evaluation will be performed during construction to verify the soils in the -mechanically - - - • Tank to be set on 5" min. sand bed or pea gravel •Tank to be backfilled uniformly all sides in lifts less than 24" a compacted Excavated material may be used backfill, provided large stones ar d for 1 I I" TANK ID �•J LLL• //1) \� % \ J•� 1 60" I ... excavation. - ,w,no,cJ CONNECT INDIVIDUAL 4" DISTRIBUTION PIPE CROWN FIELD TRENCH TO 4" PVC INLET PORT tank filled with water prior to be ng put in service for installation with • water table less than 2' below g ode • Meets C1644-06 for resilient DATE REVISION DIVERT SURFACE WATER TO HEAD OF EACH CHAMBER TRENCH (TYPICAL EACH TRENCH). NATIVE, YARD OR LANDSCAPED SURFACE INSTALL CONNECTION AS NEEDED FROM END OR SIDE INLET REVEGATATION IN IN END CAP connectors'Risers to Grade • Inlet and Outlet identified above pipe • Delivered complete with internal piping 00/00/00 XXX TOPSOIL PORT OF EACH INFILTRATOR CHAMBER END CAP. TOPSOIL LAYER 3' MIN •' BACKFILL WITH SCREENED • \%-\A, ONSITE SOILS FREE OF ROCKS IN EXCESS ► ®\ /SVA/SAA/SAA/SAA/�� . - CHAMBER END CAP �v OF 3" DIAMETER OR USE 3/4" TO 1.5' V j2. /��A /�� SCREENED ROCK °//� / 12" 18" FleBoo �Seethed Boot v !WA) 6" MIN. I Air EXCAVATED MATERIAL COMPACTED \ 1 t VIM _ II WNIM _ LEACHING " �a:� TO 90%STANDARD PROCTOR �, \� 1 11" 1I" ,;� a //� CHAMBER ALLOWABLE BURY Water Table) _ LEACHING /A 12" (Based on A FILTER FABRIC \ WATER TABLE ALLOWABLET ' 4•" �• ���•CHAMBER 4" MIN. ,' $." ��r(-_, � BACKFILL LAYER NATURAL ONSITE EA'( o, - a" 2 - o CHAMBER END CAP CONNECTION DETAIL � �' � 4" SUITABLERBACKFILLD OR SOILS FREE OF ROCKS jV� 6" - 0 3 - 0" ' • N.T.S. CLASS 6 \/ jA jA jA jA jA jA/ \/ / /V//V//V//V//V//V// A' 2• - 0" 3• - 0" -. 3"LEVELING COARSE OF ASTM 33 , / /�. /A/iAAAiA 3' - o" a - o"-130" CONCRETE SAND DISTRIBUTION BOX LID DRY a - D" Section COMPACTED SUBGRADE SELECT SIL REPLACEMENT AT GROUND SURFACE SCARIFY/TILL BOTTOM SURFACE TO A AS NEEDED IF EXCESSIVE COBBLES OR TRENCH CROSS-SECTION FOR DEPTH OF 3" AND RAKE LEVEL BOULDERS ARE ENCOUNTERED. USE 4" View RISER SECTION SDR -35.26 OR SCHD-40 PIPES FILTER SAND LEVELLING COURSE. .� BAFFLE NOTE: ALL CHAMBERS IN EACH TRENCH MUST BE INSTALLED ON LEVEL UNDISTURBED EARTH SILT N.T.S. GRADE. MAINTAIN 6' OF UNDISTURBED SOIL BETWEEN TRENCHES. THE Digging Specs Invert Dimensions Net capacity Net Weight TITLE 4" DISTRIBUTION LOAM SOIL. GRAVITY LINE ELEVATION OF ADJACENT TRENCHES MAY VARY. MAXIMUM DEPTH OF FROM SEPTIC TANK TRENCHES NOT TO EXCEED 30" BELOW PROPOSED SURFACE GRADES. 13' Long x 7' Wide Inlet Outlet Length Width Height Inlet Side Outlet Total Lid Tank Total 56" below inlet 156" I 53" I 135" 60" 68" 843 gal 416 gal 1259 gal 3120 lbs 10880 lbs 14000 lbs 81 1 OWTS PLAN INLET AND END CAPS ARE TO BE INSTALLED ON EACH END CHAMBER ROW. SII O O O 4" SOLID PVC GRAVITY � DISTRIBUTION Phone: 719-395.6764 \ipr PIPES (TYP.) TO ABSORPTION FEILD INVERT IN VALLEY Fax: 719-395-3727 IF EXCESSIVE LARGE COBBLES OR BOULDERS ARE ENCOUNTERED IN ANY PART 8" AGREGATE BASE COURSE OF THE EXCAVATION, OVER EXCVATE AND BACKFILL WITH SAND OR SUITABLE COMPACTED SUBGRADE SCREENED NATIVE SOILS. 0 PRECAST, Inc. Website: www.valleyprecast"com Buena Vista, Colorado Email: frontdesk@valleyprecast.com _.Cal Know what's below. I before you dig. DRAWING NO. CALL 2 -BUSINESS DAYS IN ADVANCE DISTRIBUTION BOX DETAIL CHAMBER TRENCH CROSS SECTION DETAIL BEFOREDIG, C- 1 .0 THEYOU NGGRADE, NDERGROUND N.T.S. N.T.S. MEMBER UTILITIES