HomeMy WebLinkAboutHigh Strength Bolt Inspection Report 11.20.19West Slope Testing & Inspection LLC Report #1 3177 Glendam Dr. Grand Junction, CO 81504 Page 1 of 1 Phone: 970-434-6988 Cell: 970-260-2844 Inspection Report Date: 11-20-19 Project: Metal Building Address: 62 County Rd. 113 Glenwood Springs, CO Building Permit No: BLCO-09-18-5452 Contractor that Performed Work: Tally Ho Construction Inspection of shop fabrication or field work at job site: Field Report: Inspected high strength A325 bolting at the main and portal frame column & rafter connections. The high strength A325 bolting inspected above appeared to be in substantial conformance with the plans & the AISC/RCSC Specification for high strength bolting except as noted below. 1) A325 grade bolts needed installed at some of the portal frame column, end wall, and center wall column connections where '/2" A307 bolts had been inadvertently installed. Inspector/Technician: Douglas E Young Douglas E. Young ICC Certification #5102224 tr ctur 1 Welding Special nspector ctu I Stee(& Bol p ial Inspector p lied irepr ecial Inspector