Loading...
HomeMy WebLinkAboutObservation of Excavation 11.11.2019I + � ensc Assaclat�ri Ma. [3antEr:hni��a1 artd M�tari�ls IwnuisleeN and Fnwlronenarllal Srlentisin 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Employee Owned Company www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado November 11, 2019 Great Lakes Construction Attn: Chris Lake P.O. Box 313 New Castle, Colorado 81647 t;l cchris 1 @gmail. coin Subject: Gentlemen: RECEIVED ULt.. U V ,CUL GARFIELD COUNTY COMMUNITY DEVELOPMENT Project No. 19-7-679 Observation of Excavation, Proposed Retaining Wall, 115 Chaparral Circle, Glenwood Springs, Colorado As requested, a representative of Kumar & Associates, Inc. observed the excavation at the subject site on November 8, 2019 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were performed in accordance with our agreement for professional engineering services to Great Lakes Construction, dated November 7, 2019. The retaining wall design is reinforced concrete construction supported on a continuous spread footing sized for an allowable bearing pressure of 2,000 psf with a width of 3 to 4 feet. An equivalent fluid, lateral earth pressure of 40 pcf was assumed behind the wall. At the time of our visit to the site, the wall had been constructed and the excavation had been cut in one level from 2% to 5 feet below the adjacent ground surface. The soils exposed in the bottom of the excavation consisted of stiff, sandy silty clay with scattered gravel. Results of swell -consolidation testing performed on a sample taken from the site, shown on Figure 1, indicate the soils have low to moderate compressibility under conditions of loading and wetting. No free water was encountered in the excavation and the soils were moist and not frozen. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 2,000 psf should be adequate for support of the proposed retaining wall. The exposed soils tend to compress when wetted and there could be some post -construction movement mainly if the bearing soils become wet. The footing should be provided with adequate soil cover above its bearing elevation for frost protection. The retaining walls can be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 40 pcf for imported granular soil such as road base as backfill. A perimeter foundation drain should be provided to prevent temporary buildup of hydrostatic pressure behind the wall. Backfill Great Lakes Construction November 11, 2019 Page 2 placed behind the structure should be compacted to at least 90% of standard Proctor density and the surface graded to possess a positive slope away from the wall. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. If you have any questions or need further assistance, please call our office. Sincerely, Kumar & Associates, Inc. Steven L. Pawlak, SLP/kac Attachment: Figure 1 - nsolidation Test Results Kumar & Associates, Inc. 0 Project No. 19.7.679 1 CONSOLIDATION —2 SAMPLE OF: Sandy Silty Clay FROM: Bottom of Excavation 11/8/19 WC = 16.2 %, DD = 106 pcf —200 = 71 ihe.. lest repute wpb' to N. .. toted. Th. .nonnet to roprnareed. erorpt foA, hehhnh the .dnen opproo l et 'New and heseclslei, he Swell C wo dellOn teshlrw PMMGm..d In eccordoncs .r h MIY i-446. f I I ADDITIONAL COMPRESSION �I UNDER CONSTANT PRESSURE 1 DUE TO WETTING 1.0 19-7-679 Kumar & Associates APPLIED PRESSURE - KSF 10 100 SWELL—CONSOLIDATION TEST RESULT Fig. 1