HomeMy WebLinkAboutFinal Onsite Septic Vault Inspection 11.06.2019SANBORN
111 HEAD
Building Trust. Engineering Success.
Mr. John Kuersten
Kuersten Construction, LLC
PO Box 1530
0013 Powerline Road
Rifle, Colorado 81650
Re: Final Onsite Septic Vault Inspection
Scale House and Administrative Buildings
Garfield County Landfill
Rifle, Colorado
Dear Mr. Kuersten:
3350 Peoria Street, Suite 150
Aurora, CO 80010
November 6, 2019
File No. 4622.00
Sanborn, Head and Associates, Inc. (Sanborn Head) observed the installed septic vault for
the Garfield County Landfill on October 30, 2019. The installed septic vault is a 1,500 -gallon
two compartment pre -cast concrete tank. The transport line from the scale building to the
tank consists of a 4 -inch diameter PVC pipe sleeved through an 8 -inch ductile iron pipe to
protect it from anticipated traffic loads as the transport line will be driven over by vehicles,
per our design. The transport line from the administrative building to the septic vault is a 4 -
inch diameter PVC pipe and did not require a protective sleeve since the building is directly
next to the septic vault and will not experience any traffic loading. Risers for the septic tank
were not installed at the time of the evaluation.
It is our opinion that the septic vault has been installed in general conformance with the
engineering plans and specifications prepared by Sanborn Head dated September 17, 2019.
Thank you for the opportunity to provide you with our services. If you have any questions,
please do not hesitate to call.
Very truly yours,
Sanborn, Head & Associates, Inc.
Marcel Kozlowski, P.E.
Senior Project Manager
cc: Deborah Fiscus, Garfield County Landfill
MBK/TWR:mbk
P:\4600s\4622.00\Work\Permitting\Septic Vault Observation Letter\20191106 Garfield County LF - Septic Vault Installation
Observation.docx
SANBORN, HEAD & ASSOCIATES, INC.
www.sanbornhead.com
(2) 0195"0x6' SIMPSON
55WH SCREW
SIMPSON LCE6 POST CAP
6"X6" PT KNEE BRACE
TYP. IN EACH DIRECTION
CORNER POSTS ONLY
(2) 0.195"066" SIMPSON
SDWH SCREW
6"X6" PT POST
KICKER DETAIL
»' DLA. J -BOLT,
WEDGE ANCHOR, OR EPDXY
BONDED ALL THREAD BOLT
w/ 4" EMBEDMENT
2'-0' MIN
of
SCALE: 3/4" = 1r-0"
SIMPSON ABUB6Z
1
1E11 1E1 ilEFFFE-
PATIO POST PAD
FOUNDATION PAD
RE: FND PLAN FOR SIZE
SCALE: 3/4" = 1'-0"
3,
606 POST wl
SIMPSON LCE6
POST CAP, TYP. &
ABU66 BASE
PROVIDE 6X6
KICKER. RE:
12'-0"
DETAIL 3/51.0
PROVIDE 1SYlr
SCR. PILASTER TO
36" FROST DEPTH.
REINFORCE w/ (4)
#4 VERTICAL BARS.
(ONE EACH
CORNER) RE: 2/S1.0
SIMPSON UL26Z
PROVIDE 16'51&'
SCR. PILASTER TO
36" FROST DEPTH
REINFORCE w/ (4)
#4 VERTICAL BARS.
(ONE EACH
CORNER) RE: 2/61.0
6x6 POST
SIMPSON BC6R
COLUMN CAP, TYP.
& ABU66 BASE
SIMPSON ML2BZ
PROVIDE 161116`
SOR. PILASTER TO
36" FROST DEPTH.
REINFORCE w/ (4)
#4 VERTICAL BARS
(ONE EACH
CORNER) RE: 2/S1.0
11,6"
(3) 2x12 PT BEAM (FLUSH)
2X12 PT JOISTS AT 0 24' O.C.
W/ 28 OA STEEL DECK ATTACKED
1RV T091501-WAU SCREWS* B' O.C.
AT EACH RAFTER.
2 r>iBEAt
(FLUS1
2%12 PTJ01.5TS AT 24'O C.
W/ 26 GA STEEL 0E06 ATfACNEO
M# T04150HWMA SCREWS 8" 0-C.
AT EACH RAFTER.
(3) 2x12 BEAM (FLUSH)
64 POST w/
SIMPSON LCE6
POST CAP, TYP. &
ABU66 BASE
PROVIDE 6X6
KICKER. RE:
DETAIL 3/61.0
FRAMING PLAN
6x6 POST w/
SIMPSON LCE6
POST CAP, TYP. &
ABU66 BASE
PROVIDE 6X6
KICKER. RE:
DETAIL 3/01.0
PROVIDE 18'518"
SOR. PILASTER TO
36" FROST DEPTH.
REINFORCE w/ (4)
#4 VERTICAL BARS.
(ONE EACH
CORNER) RE: 2/51.0
1
51MPBON ML26Z
PROVIDE 18'518"
SOR. PILASTER TO
36" FROST DEPTH.
REINFORCE w/ (4)
#4 VERTICAL BARS.
(ONE EACH
CORNER) RE: 2/51.0
6x5 POST w/
SIMPSON BC6R
COLUMN CAP, TYP.
& ABUSE BASE
SIMPSON ML26Z
6x6 POST 64
SIMPSON LCE6
POST CAP, TYP. &
ABU66 BASE
PROVIDE 6X6
KICKER. RE:
DETAIL 3/51.0
SCALE: 1/4" = 1'-0"
PROVIDE 18"018'
SOR. PILASTER TO
36" FROST DEPTH
REINFORCE wl (4)
#4 VERTICAL BARS.
(ONE EACH
CORNER) RE: 2/S1.0
EVstudio
Denver, CO
Evergreen, CO
Agee, TX
202.670 7242
deelenee.. n core
w,.wavaw6.eore
Conbd:
SPECIALTY MODULAR
GARFIELD LAND FILL AWNING
19323
75 COUNTY ROAD 246
RIFLE, CO 81650
9
.waFa
DATE: 11513013
AWNING FRAMING PLAN
31.0
GENERAL NOTES CONCRETE:
1. THESE DRAWINGS ARE "BUILDERS PLANS" INDICATING GENERAL DESIGN INTENT ONLY. IT I5 THE BUILDER'S
RESPONSIBILITY TO PROVIDE ANY ADDITIONAL CONSTRUCTION DETAILS REQUIRED AND TO DICTATE
METHODS OF CONSTRUCTION. THE BUILDER SHALL VERIFY ALL DIMENSIONS OF MANUFACTURED
COMPONENTS AND RELATIONSHIPS BETWEEN MATERIALS OR COMPONENTS. THE BUILDER SHALL VERIFY
EXISTING CONDITIONS AND DIMENSIONS SHOWN ON THE DRAWINGS INCLUDING ALL EXISTING GRADES AT
THE SITE.
2. THIS ISA CUSTOM DESIGN, THESE PLANS MAY NOT BE USED ON ANY OTHER SITE WITHOUT THE
ENGINEER'S PRIOR, WRITTEN APPROVAL
3. ANY CHANGES TO THESE PLANS WITHOUT PRIOR WRITTEN CONSENT BY THE ENGINEER SHALL
CONSTITUTE ACCEPTANCE OF RESPONSIBILITY BY THE BUILDER AND OWNER OF THAT CHANGE.
4. THE BUILDER/CONTRACTOR AND ALL SUBCONTRACTORS SHALL CONFORM TO ALL APPLICABLE BUILDING
CODES.
5. UTILIZE DETAILS AS APPLICABLE.
6. DISCHARGE ROOF DOWNSPOUTS AND ALL OTHER WATER COLLECTION SYSTEMS WELL BEYOND THE LIMITS
OF THE BACKFILL. A MINIMUM OF 5 FEET.
7. FRAMER RESPONSIBLE FOR BACKOUT FRAMING REQUIRED AT PLUMBING AND HEATING RUNS & CHASES.
DESIGN PARAMETERS
DESIGN CODES:
1- IRC 2015
2. ASCE 7
3. AISC STEEL CONSTRUCTION MANUAL
4. ACI BUILDING CODE 318
DESIGN LOADS WITH LOCAL AMENDMENTS:
1. SEISMIC LOADS
1.1 DESIGN CATEGORY: C
2. WIND LOADS
2.1. BASIC WIND SPEED 90 MPH (3 SEC GUST), 120 MPH (ULTIMATE)
2.2. EXPOSURE CATEGORY C
3. ROOF LOADS
3.1. ROOF SNOW LOAD: Pf 40 PSF
3.2. DRIFTING, SLIDING, AND UNBALANCE SNOW CALCULATED IN ACCORDANCE WITH IBC CHAPTER 16
4. GROUND SNOW 47 PSF
5. WEATHERING: SEVERE
6. FROST DEPTH: 36 INCHES
7. TERMITE INFESTATION: SLIGHT TO MODERATE
8. DECAY: SLIGHT
STRUCTURAL STEEL:
1. STRUCTURAL STEEL MEMBERS SHALL CONFORM TO THE FOLLOWING MINIMUM YIELD STRENGTH AND
ASTM SPECIFICATIONS:
SPECIFICATIONS Ga
A. STRUCTURAL STEEL DECK 26
2. FABRICATION AND ERECTION SHALL BE IN ACCORDANCE WITH THE AISC SPECIFICATION AND CODE OF
STANDARD PRACTICE, LATEST EDITIONS.
3. ALL FIELD CONNECTIONS SHALL BE MADE WITH j' DIAMETER ASTM A307 BOLTS - UNO
4. MINIMUM WELD SIZE TO BE 3/16" UNO
1. CONCRETE SHALL BE 3000 PSI COMPRESSIVE STRENGTH AT 28 DAYS. CONCRETE SHALL HAVE A WATER
TO CEMENT RATIO OF 0.50 OR LESS. CEMENT TYPE SHALL BE TYPE I OR TYPE II MODIFIED.
SLUMP: 4" +/- 1"; OR UP TO 8" MAX IF PLASTICIZER 15 USED
AIR CONTENT: 6% +/-1 %
2. REFER TO ACI 318 FOR ADDITIONAL INFORMATION.
3. DO NOT PLACE BACKFILL AGAINST FOUNDATION UNTIL CONCRETE HAS CURED AND FOUNDATION
ADEQUATELY SHORED- BACKFILL TO REQUIRED GRADE ELEVATION AND SLOPE AWAY FROM BUILDING.
4. CONCRETE PROTECTION FOR REINFORCEMENT (UNO)
CONCRETE POURED AGAINST EARTH 3"
CONCRETE POURED IN FORMS BUT EXPOSED TO EARTH AND WEATHER:
#5 BARS OR SMALLER 1 1/2"
BARS LARGER THAN #5 2"
SLABS 3/4"
FOOTING FOUNDATION NOTES
1. FOUNDATIONS, WALLS AND FOOTINGS ARE DESIGNED BASED ON: ASSUMED
MAXIMUM BEARING CAPACITY OF 2000PSF
2. CONTRACTOR SHALL NOTIFY ENGINEER OF ANY UNANTICIPATED SOILS CONDITIONS.
WOOD FRAMING
SAWN LUMBER:
1 STUDS AND PLATES SHALL BE #2 STRUCTURAL LIGHT FRAMING, HEM -FIR OR BETTER. FINGER JOINTED
STUDS ALLOWED PROVIDED THEY MEET GRADE QUALITY.
2. FOUNDATION PLATES SHALL BE REDWOOD CONSTRUCTION COMMON OR PRESSURE TREATED HEM -FIR
AND ANCHORED TO FOUNDATION PER CONCRETE NOTES.
3. ALL MULTIPLE BEAM HEADERS SHALL BE ATTACHED IN ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS. FOR SAWN LUMBER, USE (2) ROWS OF 16d NAILS @ 16" O.C.. USE NAILING BOTH SIDES
FOR 3 OR 4 PLYS.
EPDXY
1. ALL EPDXY SPECIFIED IN THESE PLANS SHALL BE ONE OF:
A. SIMPSON SET -XP ICC -ES ESR -2508, MIN- BASE TEMPERATURE 50 DEG F.
B. HILTI HIT-HY 200 ICC -ES ESR 3187, MIN. BASE TEMPERATURE 14 DEG F.
METAL CONNECTORS:
1. METAL CONNECTORS SPECIFIED 'SIMPSON' ON PLANS ARE MANUFACTURED BY SIMPSON STRONG -TIE, INC.
METAL CONNECTORS SPECIFIED 'USP' ON PLANS ARE MANUFACTURED BY UNITED STEEL PRODUCTS.
SUBSTITUTIONS BY OTHER MANUFACTURERS ALLOWED PROVIDED STRENGTH OF SPECIFIED CONNECTORS
IS MET OR EXCEEDED. NAILING/INSTALLATION OF CONNECTORS TO BE PER MANUFACTURER'S
RECOMMENDATIONS.
2 PROVIDE HURRICANE ANCHORS (SIMPSON H2.5/H2-5AIH2.5T OR USP RT7 HURRICANE CLIPS AT EACH
TRUSS/RAFTER AND ADD'L SIMPSON HTZ OR USP RT20 AT ALL GIRDER TRUSSES, TYP. U.N.0)- PROVIDE
REQUIRED BLOCKING AT ALL TRUSS / RAFTER BEARING. TRUSS DESIGNER TO PROVIDE ADDITIONAL
HOLDOWNS FOR UPLIFT LOADS EXCEEDING H2.5 AND H71
3. PROVIDE ICC APPROVED JOIST HANGERS AT ALL "FLUSH FRAME" CONDITIONS AND AS DEPICTED ON
FRAMING PLANS. PROVIDE ANY OTHER POST BASES, MULTIPLE JOIST HANGERS, AND BEAM CONNECTORS
AS REQUIRED. INSTALL WITH NUMBER AND TYPE OF NAILS RECOMMENDED BY MANUFACTURER REFER "•..,.-..-,=--•.M•-•w.,
HANGER SCHEDULE.
EVstudio
Denver, CO
Evergreen, CO
AUCin, TX
3W Gro -7242
tleeigneeveludio nom
0
z_
z
Q
ea
5JJ
DLa
OzOt
00
0 zo
Q W_ D
5 W O w
w U J
LL
CO 0 r Q
19323
w.vecx7me
HANGER SCHEDULE (UNLESS OTHERWISE NOTED)
MEMBER
FACE MOUNT HANGER
TOP FLANGE HANGER
SIMPSON
USP
SIMPSON
USP
(1)2x12
LUS210
JUS210
NA
NA
2-2x12
HU212-2 OR HUC212-2
HD212-2 OR HD212-21F
NA
NA
NOTE: ALL HANGERS AT (1) -PLY BEAMS ARE APPROVED TO USE EQUIVALENT 1 1/2" NAIL
IN/MIN 0, BM
CHECKED BY TA
GENERAL NOTES
SO.0