HomeMy WebLinkAboutORIGINAL Observation of Excavation & Perc Testing 06.30.2006HEPWORTH -PAWLAK GEOTECHNICAL
June 30, 2006
Character Builders
Attn: Steve Maznio
P.O. Box 680
New Castle, Colorado 81647
Hepworth-Pawlak Georechnical, Inc.
5020 Canty Road 154
Glenwood Springs. Colorado 81601
Phone: 970=945-7988 -
Fax 970-945-8454
hpw:(Qhrigeotech.com
Job No. 106 0593
Subject: Observation of Excavation and Percolation Testing, Proposed Residence,
_got "A, Mayfly mid, Garfield ounty,k-olorado
Dear Mr. Maznio:
As requested, a representative of Hepworth-Pawlak Geotechnical, Inc. obserfred the
excavation at the subject site on June 22, 2006 to evaluate the soils exposed for
foundation support. Percolation testing was conducted on June 23, 2006. The findings
of our observations and recommendations for the foundation design are presented in
this report. The services were performed in accordance with our agreement for
professional engineering services to Character Builders, dated June 22, 2006:
Hepworth-Pawlak Geotechnical, Inc. previously performed a -preliminary geotechnical
study for the Mayfly Bend Subdivision and reported our findings June 16, 2000, Job
No:100 412.
The proposed residence will be one and two story structural panel construction above a
shallow crawlspace with an attached slab -on -grade garage. The septic system is
proposed in the northeast corner of the propeaty..
Observation of Excavation: At the time of our visit to the site, the foundation
excavation had been cut in one level from one to two feet below the adjacent ground
surface. The soils exposed in the bottom of the excavation consisted of silty sandy
gravel with cobbles and small boulders. Silty sand layers were observed in the northeast
and SoutbweSt-corners and the excavation base was loose. No free water was
encountered in the -excavation and the soils were slightly moist -to moist. We
recommend the -excavation base be moistened and compacted prior to placing concrete.
Foundation Recommendations: Considering the conditions exposed in the excavation
and the nature of the proposed construction, spread footings placed on the undisturbed
natant soil designed for an allowable soil beating pressure of 1,000 psf should be
Parker 303-841-7119 • Colorado Springs 719-633-5562 • Silverthorne 970-468-1989
Character Builders
June 30, 2006
Page 2
adequate for support of the proposed residence. Footings should be a minimum width
of 16 inches for continuous -walls and 2 -feet for columns. Exterior footings should be
provided with adequate soil cover above their bearing elevations for frost protection:
Continuous foundation walls should be reinforced top and bottom to span local
anomalies such -as -by assuming an unsupported length of at least 10 feet Foundation
walls -acting -as. retaining structures should alsobe designed to resist a -lateral- earth
pressure based on an equivalent fluid unit weight of at least 45 pcf for on-site gravel
soil as backfill Structural fill placed within floor slab areas can consist of - the :on-site
gravel soils, devoid of topsoil and oversize rock, compacted to at least 95% of standard
Proctor density at a moisture content near optimum. Backfill placed around the
structure should be compacted and the surface graded to -prevent ponding within at least
10 feet of the building.
Percolation Testing: Percolation tests were conducted on June 23, 2006 to evaluate
the feasibility of an infiltration septic disposal system at the site. One profile pit and
three percolation holes were dug at the locations shown ' Fig . 1. The test holes
(nominal 12 inch diameter by 12 inch deep) were hand dug at the bottom of shallow
backhoe pits and were soaked with water one day prior to testing. The soils exposed in
the percolation holes are similar to those exposed in the Profile Pit and below one foot
of topsoil consist of 2 feet of silty sand overlyin sandy gravel with cobbles and small
boulders to the maximum depth excavated of 51/2 feet. Free water was encountered in
the Profile Pit at a depth of 51 feet below the ground surface.
The percolation test results are presented in Table I and indicate a percolation rate of 1
to 2 minutes per inch. Eine to the relatively fast percolation rates and elevated"
groundwater, we recommend the iniiitration area be designed by a civil engineer.
Limitations: The recommendations submitted in this letter are based on our
observation of the soils exposed within the foundation excavation and do not include
subsurface exploration to evaluate the subsurfaceconditions within the loaded depth of
foundation influence. This study is based on the assumption that soils beneath the
footings have equal or better support than those exposed. The risk of foundation
movement may be greater than indicated in this report because of possible variations in
the subsurface conditions. In order to reveal the nature and extent of variations in the
subsurface conditions below the excavation, drilling would be required. It is possible
the data obtained by subsurface exploration couldchangethe recommendations
Job No. 106 0593
Character Builders
June 30, 2006
Page 3
contained in this letter. Our services do not include determining the presence,
prevention or possibility of mold or other biological contaminants (MOBC) developing
in the future. If the client is concerned about MOBC, then a professional in this. special
field of practice should be consulted.
If you have any questions or need further assistance, please call our office.
Sincerely,
HEPWORTH - PAWLAK GEOTCHNICAL, INC.
Louis E. Eller
Reviewed by:
ZpO Rf�1s
t�' Ay
I:
Daniel E. Hardin, P.3 I
LEE/ksw 4..fi0!!Al E;
irn n °'
attachments Figure 1 - Location of Percolation Test Holes
Table 1 - Summary of Percolation Test Results
ce : Timberline Engineering - Attn: Dave Powell
lob No. 106 0593
1
106 0593
IRRIGATION
DITCH
.APPROXIMATE Sa_AE
= So
/ 7-7
O
WELL
-Y,
I
I
BUILDING
1 ENVELOPE
PONDEROSA PINES WAY
1.4
HEPWORTI.PAWLAK G OTECHNI CAL
PROPOSED
RESIDENCE
i
P2L AP3
PROFILE PIT
LOCATION OF PERCOLATION TEST
HOLES
Figure 1