1
THE ATTACHMENT
PATTERN SHOWN IS THE
STANDARD PATTERN FOR
FIELD ATTACHMENT
REQUIRED BY MULE -HIDE.
THE ATTACHMENT IN THE
PERIMETER AREA IS
INCREASED 50% AND 75%
IN THE CORNERS.
0
0
0
0 0
0 0
0
0
0
/ / /
N
T
0 0
0
N
0
(0
/
6"
12"
24"
48"
6"
/
6"
12"
/
12"
96"
6"
12"
/ 24" /
MULE -HIDE
PRODUCTS CO.,INC.
2003
4' X 8' INSULATION ATTACHMENT (1 PER 2 SF.)
STANDARD ATTACHMENT
INSULATION ATTACHMENT - OPTION 1
SELF -ADHERING MOD BIT SYSTEMS
DETAIL NO.:
MH -MB -INS -1
THE ATTACHMENT
PATTERN SHOWN IS THE
STANDARD PATTERN FOR
FIELD ATTACHMENT
REQUIRED BY MULE -HIDE.
THE ATTACHMENT IN THE
PERIMETER AREA IS
INCREASED 50% AND 75%
IN THE CORNERS.
(V
6"
/ 12"
24" /4
48"
6"/I,
11
12"
4
12"
96"
6"
/ 12" /
24"
4' X 8' INSULATION ATTACHMENT (1 PER 2 SF.)
STANDARD ATTACHMENT
(0
4
N
MULE -HIDE
PRODUCTS CO.,INC.
2003
INSULATION ATTACHMENT - OPTION 1
SELF -ADHERING MOD BIT SYSTEMS
DETAIL NO.:
MH -MB -INS -1
J
,6
18"
24"
48"
18"
24"
96"
18" / 18" / 6"
24"
24"
4' X 8' INSULATION ATTACHMENT (1 PER 1.33 SF)
STANDARD ATTACHMENT (24 PER BOARD)
MULE -HIDE
PRODUCTS CO.,INC.
2003
INSULATION ATTACHMENT - OPTION 3
SELF -ADHERING MOD BIT SYSTEMS
DETAIL NO.:
MH -MB -INS -3
0 0 0
0 0 0
0 0 0
0 0
0
0
0
N
N
0
/
N
6
'1
18"
18"
18"
24" /
48"
24"
96"
24"
18" 6"
i
24"
4' X 8' INSULATION ATTACHMENT (1 PER 1.33 SF)
STANDARD ATTACHMENT (24 PER BOARD)
MULE -HIDE
PRODUCTS CO.,INC.
2003
INSULATION ATTACHMENT - OPTION 3
SELF -ADHERING MOD BIT SYSTEMS
DETAIL NO.:
MH -MB -INS -3
J
(
MH UNIVERSAL
SINGLE PLY SEALANT \ ` WATER CUT-OFF MASTIC
I..--3/4" TO 8"
STAINLESS STEEL
BANDING CLAMP
APPROVED -
INSULATION
MIN. 1-1/2"
TPO PRE -MOLDED
PIPE BOOT
MH HDP OR EHD
FASTENER AND 2.4" SEAM
PLATE (NOTES 2, 3 & 4)
HOT AIR WELD
' (NOTE 5)
TPO REINFORCED
MEMBRANE
MIN. 1-1/2"
HOT AIR WELDE
SEAM
PRE -MOLDED SEAM PLATES
PIPE BOOT AROUN2, 3 & 4)
-TPO
REINFORCED
MEMBRANE
CUT -EDGE
SEALANT
MIN 1-4" HOT AIR WELD
TARGET PATCH REQUIRED WHEN FIELD SEAM
INTERSECTS PIPE BOOT FLANGE
NOTES:
1. REMOVE ALL LEAD AND OTHER FLASHING BEFORE INSTALLING FIELD FABRICATED PIPE SEAL.
2. ON MECHANICALLY ATTACHED SYSTEMS, INSTALL 3 FASTENERS AND PLATES AROUND PIPE EQUALLY SPACED. FASTENERS
MAY ALSO BE POSITIONED MAXIMUM 12" FROM PIPE, FASTENED 12" 0.C. AND FLASHED WITH TPO REINFORCED
MEMBRANE.
3. FASTENERS AND SEAM PLATES ARE NOT REQUIRED ON ADHERED SYSTEMS UNLESS PROJECTION DIAMETER EXCEEDS 18".
4. IF SEAM PLATES CANNOT BE INSTALLED AS SHOWN THEY CAN BE POSITIONED OUTSIDE THE PIPE FLSHING FLANGE AS
SHOWN ON DETAIL MHT -UN -521 A
5. PIPE BOOT DECK FLANGE MUST BE HOT AIR WELDED A MINIMUM OF 1-1/2" BEYOND SEAM PLATES.
6. TEMPERATURE OF PIPE NOT TO EXCEED 160' F
7. INSTALL A SECTION OF TPO REINFORCED MEMBRANE OVER SEAM INTERSECTIONS PRIOR TO INSTALLING PRE -MOLDED PIPE
BOOT - SEE INSET.
8. DO NOT CUT PIPE BOOTS TO PULL AROUND PROJECTION. PRE -MOLDED PIPE BOOTS MUST BE SLIPPED OVER THE PIPE.
9. PRE -MOLDED PIPE BOOTS ARE NOT TO BE USED AS PITCH PANS.
MULE -HIDE
PRODUCTS CO., INC.
PRE -MOLDED PIPE BOOT
SYSTEMS:
ALL TPO SYSTEMS
DETAIL NO.:
MHT -UN -520
REVISION DATE: 10/2013
1. INSTALL CONTINUOUS CLEAT.
2. INSTALL MEMBRANE COATED
METAL WITH Y4" JOINTS
BETWEEN ADJOINING
SECTIONS.
Lu
COATED METAL
w CONTINUOUS CLEAT,
r� SEE NOTE 4
INSTALL 2" WIDE DUCT TAPE
OVER JOINTS OF MEMBRANE
COATED METAL & COMPLETELY
COVER THE JOINT.
HOT AIR -WELD 1Y2"
CUT -EDGE SEALANT
SEE NOTE 5
MEMBRANE
RING -SHANK
NAILS ® 6" O.C.
HD PURLIN
FASTENER
HEAT WELD 6" WIDE PIECE OF POSITION MULE -HIDE REINFORCED
MULE -HIDE NON -REINFORCED FIELD MEMBRANE AND HEAT WELD TO
MEMBRANE OVER THE JOINT. MEMBRANE COATED METAL, A MINIMUM
OF 1Y2" AS SHOWN.
SEE NOTE 4
MH REINFORCED
TPO MEMBRANE
ACCEPTABLE -
INSULATION
1
11V
TREATED WOOD NAILER
(BY OTHERS)
RING SHANK NAILS 6" 0.
THERMAL SPACER
STRUCTURAL PURLIN
NOTES:
-----------------
10010111,
tO
CUT -EDGE
SEALANT SEE
NOTE 5
HOT AIR
WELD
MIN. 1Y2"
1. REFER TO METAL RETROFIT SPECS FOR PROPER
WOOD NAILER FASTENING CRITERIA.
2. INSPECT THE STRUCTURAL INTEGRITY OF EXISTING
STEEL MEMBER(S) PRIOR TO ANCHORING NEW WOOD
BLOCKING.
3. THICKNESS OF WOOD NAILER(S) TO MATCH WITH
THE THICKNESS OF INSULATION.
4. SEE DETAIL T3.1 FOR METAL EDGE INSTALLATION
AND REQUIREMENTS OF ANSI/SPRI ES -1
COMPLIANCE.
5. APPROXIMATELY Ys" DIAMETER BEAD OF CUT -EDGE
SEALANT IS REQUIRED ON CUT EDGTES OF
REINFORCED MEMBRANE.
C.
NOTE:
NOT APPROVED FOR 20 -YEAR
SYSTEM WARRANTIES OR FOR
USE IN HIGH WIND AREAS
MULE -HIDE
PRODUCTS CO., INC.
2011
PERIMETER EDGE METAL
MEMBRANE COATED METAL
SYSTEMS:
METAL RETROFIT SYSTEMS
TPO MECHANICALLY ATTACHED
DETAIL NO.:
MMRT-101
J