Loading...
HomeMy WebLinkAboutPermitGarfield County Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number SEPT-6166 Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment Issue Date 03/24/2020 Expiration Date 03/24/2021 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: Tract 8, Antlers Orchard Development Parcel No.: 2127-362-00-071 Owner Name: Bobby R. and Robin G. Burkett Owner Phone: (970) 379-4609 Designed By: Jeffrey Simonson, P.E., CFM with SGM, Inc. Designer Phone: (970) 384-9005 Contractor: Bobby R. Burkett Contractor Phone: (970) 379-4609 Number of Bedrooms 4 Minimum Tank Capacity 1,250 gal Minimum Absorption 1,400 SF Permit Conditions: This OWTS Permit is approved on the condition of compliance with the design as submitted by Jeffery S. Simonson, P.E., CFM of SGM, Inc. dated March 3, 2020. Changes must be approved by Garfield County Public Health and the designer prior to construction. The OWTS will serve a four -bedroom residence and consist of a 1,250-gallon septic tank as specified in the regulations set level and accessible at grade, followed by a distribution box set level and accessible at grade to distribute effluent to 1,440 square feet of Soil Treatment Area (STA). The STA consists of 5 level gravelless chamber trenches, with 24 "Quick-4" Infiltrator chambers each (120 total) with inspection ports at the beginning and end of each trench. Maintain all setbacks and elevations as designed. The septic tank must have two compartments minimum. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of thel ystem will be issued. ;,, is '- �� � / � ; � ��L 03/24/2020 Issued By: Garfield County Environmental Health Department Date