Loading...
HomeMy WebLinkAboutPlansSYMBOL LEGEND SECTION NO. BUILDING SECTION CUT SHEET NO. DETAIL CUT DETAIL NO. SHEET NO. DETAIL CALLOUT ELEVATION NO. EXTERIOR ELEVATION SHEET NO. ROOM NAME & NUMBER LIVING DOOR MARK 100 03 MATCH LINE REFERENCE GRID LINE SPOT ELEVATION DRAWING REVISION INTERIOR ELEVATION WINDOW MARK WALL TYPE MARK W1 PROJECT DIRECTORY KATE AND ROGER WEITZ (OWNER) 804 Loveland Drive Omaha, NE 68114 weitz.kate@gmail.com KA DESIGNWORKS, INC. (ARCHITECT) PO Box 12204 Aspen, CO 81612 carrie@ka-designworks.com CONTACT: Kate Weitz CONTACT: Carrie Tirrell (970) 309-7497 JANCKILA CONSTRUCTION (CONTRACTOR) 51 Sunset Drive CONTACT: Art Harju Basalt, CO 81621 (970) 9276714 art@janckilaconstruction.com ERNEST KOLLAR ENGINEERS INC. (STRUCTURAL ENGINEER) 320 Main Street Suite 203 CONTACT: Ernie Kollar Carbondale, CO 81623 (970) 963-3223 erniekollar@gmail.com 11261 VICINTY PLAN 9505 Van Dorn Drive 11251 PP ork ¢iyet PROJECT SITE 11541 11091 505 VanDorn Remodel Glenwood Spr' -fir CO PERMIT DOCUMENTS - 3/3/20 PROJECT INFO 505 VAN DORN ROAD, GLENWOOD SPRINGS, CO 81601 JURISDICTION: Garfield County PARCEL ID: 2395-032-00-013 LEGAL DESC: SUBDIVISION: Chelyn Acres TRACT: Except for a portion of 9 1.865 acres SECTION: 3 TOWNSHIP: 7 RANGE: 89 2015 INTERNATIONAL RESIDENTIAL CODE (IRC) 2015 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) AAD ADD ADJ AOR AGG AFF ALT ARCH BM BRG BET BD BS BO BLDG CAB CL CER CLR CLOS CMU COL CONC CJ CONT DP DET DIA DIM DW DN DR DS DRWG EA EL EQ EXIST EJ EXT FEC FOC FOS FIN FP FL FD FTG FDN GA Attic Access Door Addendum Adjacent Area of Refuge Aggregate Above Finished Floor Alternate Architectural Beam Bearing Between Board Both Sides Bottom Of Building Cabinet Centerline Ceramic Clear Closet Concrete Masonry Unit Column Concrete Construction Joint Continuous Damproofing Detail Diameter Dimension Dishwasher Down Drain Downspout Drawing Each Elevation Equal Existing Expansion Joint Exterior Fire Extinguisher Cabinet Face Of Concrete Face Of Stud Finish Fireproof Floor Floor Drain Footing Foundation Guage ABBREVIATIONS GALV GC GL GR GLB GYP GWB HDW HD HVAC HT HWY HOR ID INT JT LAM LAV MFG MO MTL MAX MC MECH MIN MISC NIC NA NTS OC OPG OPP OPH OD d PERF PFSM PL PLY PROD PROJ PROP R REF REFR REINF REQ'D RHSM RM Galvanized General Contractor Glass Grade Laminated Wood Beam Gypsum Gypsum Wallboard Hardware Head Heating, Ventilating, and Air Conditioning Height Highway Horizontal Inside Diameter Interior Joint Laminate Lavatory Manufacturer Masonry Opening Material Maximum Medicine Cabinet Mechanical Minimum Miscellaneous Not In Contract Not Applicable Not to Scale On Center Opening Opposite Opposite Hand Outside Diameter Penny (nails, etc.) Perforated (d) Prefinished Sheet Metal Plate Plywood Product Project Property Radius or Riser Refer Refrigerator Reinforce (d) Required Round Head Sheet Metal Screw Room RW RO SAN SECT SEW SHT SHLV SIM SL SM STC SPEC SQ STD STL STRUCT SUB SUPPL SUSP TEL TV TEMP IE THK TPH T&G T&B TO T TS TYP UG U.N.O. UNFIN UBC USG VAR VENT VIF VERT VAT V WC WP WT WIN W/ W/O WD Roof Window Rough Opening Sanitary Section Sewer Sheet Shelves Similar Sliding Sheet Metal Sound- Transmission Class Specification Square Standard Steel Structure (al) Substitute Supplement (al) Suspend (ed) Telephone Television Tempered That Is Thick Toilet Paper Holder Tounge and Groove Top and Bottom Top Of Tread Tube Steel Typical Underground Unless Noted Otherwise Unfinished Uniform Building Code United States Gage Variable Ventilate Verify In Field Vertical Vinyl Asbestos Tile Voltage Water Closet Waterproof Weight Window With (comb. form) Without Wood GENERAL NOTES A. THE AIA DOCUMENT 201, "GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION", 2017, ARE HEREBY MADE A PART OF THESE CONTRACT DOCUMENTS. COPIES ARE ON FILE AND ARE AVAILABLE FOR INSPECTION AT THE OFFICES OF THE ARCHITECT. B. THE CONTRACT DOCUMENTS CONSIST OF THE AGREEMENT, THE GENERAL NOTES, THE SPECIFICATIONS, AND THE DRAWINGS, WHICH ARE COOPERATIVE AND CONTINUOUS. WORK INDICATED OR REASONABLY IMPLIED IN ANY ONE OF THE DOCUMENTS SHALL BE SUPPLIED AS THOUGH FULLY COVERED IN ALL. ANY DISCREPANCY BETWEEN THE DIFFERENT PARTS SHOULD BE REPORTED TO THE ARCHITECT IMMEDIATELY. C. ALL WORK SHALL COMPLY WITH ALL STATE AND LOCAL CODES AND ORDINANCES, AND SHALL BE PERFORMED TO THE HIGHEST STANDARDS OF CRAFTSMANSHIP BY JOURNEYMEN OF THE APPROPRIATE TRADES. GENERALLY, ALL MATERIALS TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, UNLESS OTHERWISE REGULATED OR SPECIFIED BY ARCHITECT OR GOVERNING BODIES D. THESE DOCUMENTS ARE INTENDED TO INCLUDE ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES REQUIRED TO COMPLETE ALL WORK DESCRIBED HEREIN. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BRING TO THE ATTENTION OF THE ARCHITECT ANY CONDITIONS WHICH WILL NOT PERMIT CONSTRUCTION ACCORDING TO THE INTENTIONS OF THESE DOCUMENTS. IT IS THE RESPONSIBILITY OF THE 1/4RCHITEC TO PROVIDE DETAILS AND/OR DIRECTIONS REGARDING DESIGN INTENT WHERE IT IS ALTERED BY EXISTING CONDITIONS OR WHERE NEGLECTED IN THE DOCUMENTS. E. ANY MATERIALS PROPOSED FOR SUBSTITUTION OF THOSE SPECIFIED OR CALLED OUT BY TRADE NAME IN THESE DOCUMENTS SHALL BE PRESENTED TO THE FOR REVIEW. THE CONTRACTOR SHALL SUBMIT SAMPLES WHEN REQUIRED BY THE AND ALL SUCH SAMPLES SHALL BE REVIEWED BY THE RCHITECT BEFORE THE WORK IS PERFORMED. WORK MUST CONFORM TO THE REVIEWED SAMPLES. ANY WORK WHICH DOES NOT CONFORM SHALL BE REMOVED AND REPLACED WITH WORK WHICH CONFORMS AT THE REQUESTS AND SAMPLES FOR REVIEW THROUGH THE GENERAL CONTRACTOR'S EXPENSE. SUBCONTRACTORS SHALL SUBMIT CONTRACTOR WHEN WORK IS LET THROUGH HIM OR HER. REQUIRED VERIFICATIONS AND SUBMITTALS TO BE MADE IN ADEQUATE TIME AS NOT TO DELAY WORK IN PROGRESS. F. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ixPrI-1ITP' FOR HIS OR HER REVIEW WHERE CALLED FOR ANYWHERE IN THESE DOCUMENTS. REVIEW SHALL BE MADE BY THE ARCHITEL BEFORE WORK IS BEGUN, AND WORK SHALL CONFORM TO THE REVIEWED SHOP DRAWINGS, SUBJECT TO REPLACEMENT AS REQUIRED IN PARAGRAPH E, ABOVE. G. THE BUILDING INSPECTOR SHALL BE NOTIFIED BY THE CONTRACTOR WHEN THERE IS NEED OF INSPECTION AS REQUIRED BY THE UNIFORM BUILDING CODE OR ANY LOCAL CODE OR ORDINANCE. H. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY AND CARE OF ADJACENT PROPERTIES DURING CONSTRUCTION, FOR COMPLIANCE WITH FEDERAL AND STATE O.S.H.A. REGULATIONS, AND FOR THE PROTECTION OF ALL WORK UNTIL IT IS DELIVERED COMPLETED TO THE OWNER. I. ALL DIMENSIONS NOTED TAKE PRECEDENCE OVER SCALED. DIMENSIONS NOTED WITH "N.T.S." DENOTES NOT TO SCALE. DRAWINGS NOT TO BE SCALED, NOTIFY OF ANY CONFLICTS OR OMISSIONS J. CONTRACTOR SHALL VERIFY AND COORDINATE ALL OPENINGS THROUGH FLOORS, CEILINGS, AND WALLS WITH ALL ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS. K. CONTRACTOR WILL ASSUME RESPONSIBILITY OF ITEMS REQUIRING COORDINATION AND RESOLUTION DURING THE BIDDING PROCESS. DRAWING INDEX ARCHITECTURAL A000 A201 A202 A203 A204 COVER SHEET I ARCH BATH #2 LAUNDRY/ KITCHEN BATH #1 MASTER BATH 1 'i� DESIGNWORKS ASPEN I BASALT I COLORADO P:970.948.9510 KA-DESIGNWORKS.COM 505 VanDorn Remodel 505 Van Dorn Drive Glenwood Springs, CO 81601 DRAWING ISSUANCE INDEX ID ISSUE DATE 01 PERMIT DOCUMENTS 3/3/20, PRINT DATE: 3/3/20 7:41 PM COPYRIGHT These documents have been prepared specifically for the 505 VanDorn Remodel. They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. Reproduction prohibited without approval of the Architect. © 2020 KA DesignWorks, Inc. SHEET TITLE COVER SHEET I ARCH 0 30.6 sq ft BATHROOM #2 0 1' 2' SCALE:1/2" = 1'-0" C 4' LIGHTING KEY: RECESSED CAN WALL SCONCE JAMB SWITCH LED EXHAUST FAN EF y 21 sq ft BATHROOM #2 4�i 0 1' 2' SCALE: 1 /2" = 1 '-0' 4' Bath #2 RCP Proposed SCALE: 1/2" = 1'-0" 0 1' 2' WA L HINGED GLASS DOOR \ n c Zo ) i 0 BATHROOM #2 2' SCALE: 1/2" = 1'-0" 4' 1 I 21 sq ft NOTE: - NEW SHOWER FLOOR/TILE SURROUND/ FAUCETS - NEW TOILET - NEW TILE FLOORING - NEW LIGHTING - NEW EXHAUST FAN - (2) NEW GLASS CORNER SHELVES FOR SHOWER ® ® C I I 1 1 1 201 9 146.4 sq ft EF r\ / 10..4sgft ,- i // // III A14 \ iII iliAt • Bath #2 Proposed SCALE: 1/2" = 1 '-0" 0 1' 2' BATHROOM #2 0 2' SCALE:1/2" = 1'-0" 4' 6' RE -FINISH CABINETS BATHROOM #2 0 1' 2' SCALE: 1/2" = 1'-0" 4' Bath #2 Existing \ SCALE: 1/2" = 1'-0" 0 1' 2' 4' 1 'i� DESIGNWORKS ASPEN BASALT COLORADO P:970.948.9510 KA-DESIGNWORKS.COM 505 VanDorn Remodel 505 Van Dorn Drive Glenwood Springs, CO 81601 DRAWING ISSUANCE INDEX ID ISSUE DATE 01 PERMIT DOCUMENTS 3/3/20, PRINT DATE: 3/3/20 7:41 PM COPYRIGHT These documents have been prepared specifically for the 505 VanDorn Remodel. They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. Reproduction prohibited without approval of the Architect. © 2020 KA DesignWorks, Inc. SHEET TITLE BATH #2 LAUNDRY ROOM 0 2' SCALE: 1 /2" = 1 '-0" 4' LIGHTING KEY: O RECESSED CAN WALL SCONCE JAMB SWITCH LED EXHAUST FAN EF (4) \_/ /—\ \_/ /—\ \_/ /—\ \_/ /—\ \_/ \_/ /N \_/ /—\ /—\ \_/ /—\ \_/ /—\ l 0 LAUNDRY ROOM 2' SCALE: 1/2" = 1'-0" 4' Laundry RCP Proposed SCALE: 1/2" = 1'-0" 1 1' 2' 4' I rt I NOTE: - NEW CABINETRY - NEW DOUBLE WALL OVEN - NEW LIGHTING 0 1 2' 4' REPLACE BACKSPLASH WITH PORCELAIN SLAB REPLACE EXISTING HOOD WITH A ZEPHYR TITAN 60" - 390 CFM RE -USE EXISTING DUCTWORK REPLACE EXISTING STAINLESS STEEL BACKSPLASH WITH NEW LAUNDRY ROOM r6� 0 1' 2' SCALE: 1/2" = 1'-0" 4' Laundry Proposed 0 SCALE:1/2" = 1'-0" NEW TILE 7.5 sq ft REPLACE BACKSPLASH WITH PORCELAIN SLAB Kitchen Countertop SCALE:1/2" = 1'-0" 0 1' 2' 4' I ADJUSTABLE SHELVING 1 1'-3" LAUNDRY ROOM 1' 2' SCALE:1/2" = 1'-0" 4' Laundry Demo SCALE: 1/2" = 1'-0" 1 'kii DESIGNWORKS ASPENIBASALTICOLORADO P:970.948.9510 KA-DESIGNWORKS.COM 505 VanDorn Remodel 505 Van Dorn Drive Glenwood Springs, CO 81601 DRAWING ISSUANCE INDEX ID ISSUE DATE 01 PERMIT DOCUMENTS 3/3/20, PRINT DATE: 3/3/20 7:41 PM COPYRIGHT These documents have been prepared specifically for the 505 VanDorn Remodel. They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. Reproduction prohibited without approval of the Architect. © 2020 KA DesignWorks, Inc. SHEET TITLE LAUNDRY / KITCHEN LIGHTING KEY: EF RECESSED CAN WALL SCONCE JAMB SWITCH LED EXHAUST FAN 0 13.0 sq ft BATHROOM #1 2' SCALE:1/2" = 1'-0" 4' Bath #1 RCP Proposed \ 4 \ I \ SCALE:1/2" = 1'-0" 0 1' 2' 0 19.1 sq ft BATHROOM #1 2' SCALE: 1/2" = 1 '-0" 4' 0 LINEN CABINET BATHROOM #1 0 1 2' 4' 18 sq ft BATHROOM #1 \ \ SCALE: 1/2" = 1'-0" 0 1' 2' 4' 2 \ \ NOTE: - NEW PEDESTAL SINK - NEW SHOWER AND FAUCETS - NEW TUB - NEW TOILET - NEW FLOORING - NEW LINEN CABINET - NEW LIGHTING - (2) NEW GLASS CORNER SHELVES FOR SHOWER Bath #1 Proposed SCALE: 1/2" = 1'-0" 0 1' 2' 4' � I SCALE: 1 /2" = 1 '-0" 10.9sgft BATHROOM #1 SCALE: 1/2" = 1'-0" 4' 3 sq ft 24 sq ft BATHROOM #1 SCALE: 1/2" = 1'-0" 1 0 1' 2' 4' Bath #1 Demo \ 0 SCALE: 1/2" = 1'-0" 1' 2' 4' I I 1111 'i� DESIGNWORKS ASPEN I BASALT I COLORADO P:970.948.9510 KA-DESIGNWORKS.COM 505 VanDorn Remodel 505 Van Dorn Drive Glenwood Springs, CO 81601 DRAWING ISSUANCE INDEX ID ISSUE DATE 01 PERMIT DOCUMENTS 3/3/20, PRINT DATE: 3/3/20 7:41 PM COPYRIGHT These documents have been prepared specifically for the 505 VanDorn Remodel. They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. Reproduction prohibited without approval of the Architect. © 2020 KA DesignWorks, Inc. SHEET TITLE BATH #1 MASTER BATH 1 2' SCALE: 1 /2" = 1 '-0" 4' NICHE MASTER BATHROOM SCALE: 1/2" = 1 '-0" 4 ) 0 1' 2' 4' I — LIGHTING KEY: O RECESSED CAN WALL SCONCE JAMB SWITCH LED EXHAUST FAN EF Master Bath Proposed SCALE:1/2" = 1'-0" 0 1' 2' MASTER BEDROOM /7 31 sq ft I 4 sq ft MASTER BATHROOM SCALE: 1/2" = 1'-0" 0 1' 2' 4' I — SCALE: 1/2" 1'-0" SCALE: 1 /2" = 1 '-0" 12" DEEP SHELVES CABINET TOP WITH TWO DRAWERS BELOW HANGING UPPER - OPEN SHELVES/CUBBIES LOWER MASTER BATHROOM 0 2' SCALE:1/2" = 1'-0" 4' NOTE: - NEW PEDESTAL SINK IN NEW LOCATION - NEW SHOWER AND FAUCETS - NEW TOILET - NEW EXHAUST FAN - NEW FLOORING - NEW LIGHTING - NEW BEDROOM CABINETRY Master Bath Proposed SCALE:1/2" = 1'-0" 0 1' 2' DOUBLE HANGING t MASTER BEDROOM /064) SCALE:1/2" = 1'-0" 0 2' 4' 35 sq ft / // V V •\/ V \ 1 MASTER BATHROOM / SCALE: 1/2" = 1'-0" 1 0 1' 2' 4' Master Bath Demo SCALE: 1/2" = 1'-0" 0 1' 2' 1 'i� DESIGNWORKS ASPEN 1 BASALTICOLORADO P:970.948.9510 KA-DESIGNWORKS.COM 505 VanDorn Remodel 505 Van Dorn Drive Glenwood Springs, CO 81601 DRAWING ISSUANCE INDEX ID ISSUE DATE 01 PERMIT DOCUMENTS 3/3/20, PRINT DATE: 3/3/20 7:41 PM COPYRIGHT These documents have been prepared specifically for the 505 VanDorn Remodel. They are not suitable for use on other projects or in other locations without the approval and participation of the Architect. Reproduction prohibited without approval of the Architect. © 2020 KA DesignWorks, Inc. SHEET TITLE MASTER BATH