HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLCO-03-20-6170
T &T, LLC
Warehouse/Storage Building Shell
TBD County Road 100
Carbondale, Colorado
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL BUILDING CODE (I.B.C.)
2009 INTERNATIONAL FIRE CODE (I.F.C.) AND MANUFACTURER'S INSTALLATION
SPECIFICATIONS.
2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY'S BUILDING REQUIREMENTS &
INSPECTIONS POLICIES.
3) BUILDING IS APPROVED AS NON-SPRINKLERED, CONSTRUCTION TYPE II -B (NONCOM-
BUSTIBLE) WITH "LOW -HAZARD STORAGE" (GROUP S-2) OCCUPANCY/USE.
4) CONTACT LOCAL FIRE DISTRICT FOR REVIEW AND APPLICABLE I.F.C. REQUIREMENTS.
FIRE DISTRICT'S FINAL APPROVAL REPORT IS REQUIRED PRIOR TO FINAL BUILDING
INSPECTION & CERTIFICATE OF OCCUPANCY.
5) ANY FUTURE CHANGES TO OCCUPANCY TYPE OR USE OF THE BUILDING MUST COMPLY
WITH APPLICABLE ZONING REGULATIONS AND/OR LAND -USE CHANGE PERMITS UNDER
REQUIREMENTS OF GARFIELD COUNTY'S LAND -USE DEVELOPMENT CODE. ANY SUCH
CHANGES MAY ALSO BE SUBJECT TO ADDITIONAL BUILDING DEPARTMENT AND/OR FIRE
DISTRICT REVIEW, PERMITTING & INSPECTIONS.
6) BUILDING 15 APPROVED AS A SHELL ONLY. FUTURE TENANT FINISH PERMITS ARE
REQUIRED.
7) OPEN -HOLE SOILS REPORT IS REQUIRED AT FOOTING INSPECTION, 3000 PSF.
8) ALL HIGH STRENGTH BOLTING AND FIELD WELDING REQUIRES SPECIAL INSPECTOR PER
SPECIAL INSPECTIONS PROVISIONS OF I.B.C., CHAPTER 17. PROVIDE APPROVAL REPORT
AT FRAME INSPECTION.
9) IF APPLICABLE, ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE
ELECTRICAL BOARD. ELECTRICAL FINAL APPROVAL IS REQUIRED AT FINAL BUILDING
INSPECTION & CERTIFICATE OF OCCUPANCY.
10) ACCESSABILITY PER CHAPTER 11 IBC AND ICC A117.1. PARKING, ACCESS AND
BATHROOM MUST BE ACCESSABLE.