HomeMy WebLinkAboutPermitGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT-6229
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 04/28/2020 Expiration Date 04/28/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: TBD Highway 82, Carbondale, CO 81623 Parcel No.: 2393-134-00-104
Owner Name: Michael and Michaleen Jeronimus Owner Phone: (303) 868-9738
Designed By: Roger Neal, P.E. of High Country Engineering, Inc. Designer Phone: (970) 945-8676
Contractor: Owner
Contractor Phone: (303) 868-9738
Number of Bedrooms 6 Minimum Tank Capacity 1,750 gal Minimum Absorption 844 SF
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by High
Country Engineering, Inc. dated April 17, 2020. Changes must be approved by Garfield County Public
Health and the designer prior to construction.
The OWTS will serve a four -bedroom house and two -bedroom Barn/ADU. The Barn/ADU will be
constructed first, with the line to the main residence plumbed in at the same time. The system will
consist of a 1,500-gallon precast concrete septic tank set level and accessible at grade with an
effluent filter in the outlet tee, followed by a 500-gallon pump chamber followed by an automatic
distributing valve set level and to grade at the high point to distribute effluent to 859 square feet of
Soil Treatment Area (STA). The STA consists of five chamber trenches placed on a minimum three
feet of secondary sand filter material, with 14 chambers per trench (70 total) with inspection ports
at the beginning and end of each trench. The trenches will be pressure -dosed by a float system to
dose 67.5 gallons each pump cycle. The design calls for a pump capable of a design flow rate of at
least 17.8 GPM and a minimum total dynamic head (TDH) of 16.1 feet with 5 feet of residual head at
the last orifice. The pump control panel must be within line of site of the septic tank. Maintain all
setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval ofp system will be issued.
' , •W / #, - -Ofi---'—' 6 .
issued By: Garfield County Environmental Health
Department
Date