Loading...
HomeMy WebLinkAboutEnvelope Compliance Certificate 04.29.2020iCOMcheck Software Version 4.1.1.0 Envelope Compliance Certificate Project Information Energy Code: Project Title: Location: Climate Zone: Project Type: Vertical Glazing / Wall Area: 2015 IECC Silt Farms Silt, Colorado 5b New Construction 13% Construction Site: Owner/Agent: County Rd 331 Charles Barr Colorado River Road Silt, CO 81652 Additional Efficiency Package(s) Designer/Contractor: Eric Kraai KDA INC. 417 Monument Road Suite 7 Grand Junction, CO 81507 High efficiency HVAC. Systems that do not meet the performance requirement will be identified in the mechanical requirements checklist report. Building Area Floor Area 1-F2 (Manufacturing Facility) : Nonresidential 41765 Envelope Assemblies Assembly Gross Area Cavity Cont. Proposed Budget U - or R -Value R -Value U -Factor Factorial Perimeter CFR Insulated Roof Panel: Other Metal Building Roof, [Bldg. Use 1 - F2] (b) 1st Floor Slab: Slab-On-Grade:Unheated, [Bldg. Use 1 - F2] (d) NORTH Rated panel - ThermalSafe - MetlSpan: Other Exterior Wall, Heat capacity 0.0, [Bldg. Use 1 - F2] (b) Man Doors - TruDoor Flush-Mtl.: Insulated Metal, Swinging, [Bldg. Use 1 - F2] Overhead Doors - 432 Series: Insulated Metal, Non -Swinging, [Bldg. Use 1 - F2] CF Light Mesa - MetlSpan: Other Metal Building Wall, [Bldg. Use 1 - F2] (b) Mezzanine Windows - Kawneer 6400 Series: Metal Frame:Fixed, Perf. Specs.: Product ID Cardinal Glass, SHGC 0.40, [Bldg. Use 1 - F2] (c) EAST CF Light Mesa - MetlSpan: Other Metal Building Wall, [Bldg. Use 1 - F2] (b) Man Doors - TruDoor Flush-Mtl.: Insulated Metal, Swinging, [Bldg. Use 1 - F21 SOUTH Rated panel - ThermalSafe - MetlSpan: Other Exterior Wall, Heat capacity 0.0, [Bldg. Use 1 - F2] (b) FireRated Windows - Fireframes TOP: Metal Frame with Thermal 41765 970 7279 42 80 2720 1235 2675 42 7279 734 0.026 0.035 0.730 0.540 0.044 0.064 0.310 0.370 0.136 0.179 0.052 0.052 0.380 0.380 0.052 0.052 0.310 0.370 0.044 0.064 0.380 0.380 Project Title: Silt Farms Report date: 04/29/20 Data filename: P:\2012 - Spring Born\PROJECT DATA\2015 IECC ComCheck\2015 IECC Springborn.cck Page 1 of 9 Assembly Gross Area Cavity Cont. or R -Value R -Value Perimeter Proposed Budget U - U -Factor Factorce) Break:Fixed, Perf. Specs.: Product ID Cardinal Glass, SHGC 0.40, [Bldg. Use 1 - F2] (c) Man Doors - TruDoor Flush-Mtl.: Insulated Metal, Swinging, [Bldg. Use 1 - F2] Overhead Doors - 432 Series: Insulated Metal, Non -Swinging, [Bldg. Use 1 - F2] RoIIUp Door - FireKing: Insulated Metal, Non -Swinging, [Bldg. Use 1 - F2] CF Light Mesa - MetlSpan: Other Metal Building Wall, [Bldg. Use 1 - F2] (b) Mezzanine Windows - Kwaneer 6400 Series: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Cardinal Glass, SHGC 0.40, [Bldg. Use 1 - F2] (c) WEST CF Light Mesa - MetlSpan: Other Metal Building Wall, [Bldg. Use 1 - F2] (b) Mezzanine Windows - Kawneer 6400 Series: Metal Frame with Thermal Break:Fixed, Perf. Specs.: Product ID Cardinal Glass, SHGC 0.40, [Bldg. Use 1 - F2] (c) Man Doors - TruDoor Flush-Mtl.: Insulated Metal, Swinging, [Bldg. Use 1 - F2] Overhead Doors - 432 Series: Insulated Metal, Non -Swinging, [Bldg. Use 1 - F2] 126 240 56 2720 1235 2675 80 126 80 0.310 0.370 0.136 0.179 0.222 0.179 0.052 0.052 0.380 0.380 0.052 0.052 0.380 0.380 0.310 0.370 0.136 0.179 (a) Budget U -factors are used for software baseline calculations ONLY, and are not code requirements. (b) 'Other' components require supporting documentation for proposed U -factors. (c) Fenestration product performance must be certified in accordance with NFRC and requires supporting documentation. (d) Slab -On -Grade proposed and budget U -factors shown in table are F -factors. Envelope PASSES: Design 11% better than code Envelope Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed envelope systems have been designed to meet the 2015 IECC requirements in COMcheck Version 4. .1.0 a nd to comply with any applicable mandatory requirements listed in the Inspection Checklist. • fcza) " /''VCINT1C,C, Name - Title Signature Date Project Title: Silt Farms Report date: 04/29/20 Data filename: P:\2012 - Spring Born\PROJECT DATA\2015 IECC ComCheck\2015 IECC Springborn.cck Page 2 of 9