HomeMy WebLinkAboutPermitGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT -6295
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 06/03/2020 Expiration Date 06/03/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable.
Project Address: 4140 County Road 320 Rifle, CO 81650 Parcel No.: 2175-343-00-181
Owner Name: Pierre and Crystal Loncle Owner Phone: (907) 315-7908
Designed By: CBO, Inc. Designer Phone: (970) 309-5259
Contractor: Sacred Ground Excavating Contractor Phone: (970) 618-2489
Number of Bedrooms 4 Minimum Tank Capacity 1,250 gal Minimum Absorption 735 ft2
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the application and design
documents as submitted by CBO, Inc. dated May 24, 2020. Changes must be approved by Garfield
County Public Health and the designer prior to construction.
The repaired OWTS will serve a four-bedroom house. The system will consist of an existing 1,000 -
gallon septic tank, followed by a 500 -gallon single chamber septic tank, followed by a distribution
box set level and to grade with flow equalizers for each outlet to distribute effluent to 768 square
feet of Soil Treatment Area (STA). The STA consists of 4 gravelless trenches of 16 Quick4 chambers
per trench (64 total) with observation ports at the beginning and end of the trenches. Maintain all
setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the;jstem w,iII be issued.
Z ;( () ,/iZi '. i:.,
6/03/2020
Issued By: Garfield County Environmental Health
Department
Date