HomeMy WebLinkAboutCorrespondenceDave Argo
From: Jody Daniels <ghdgrowit@aol.com>
Sent: Tuesday, June 2, 2020 6:22 PM
To: Dave Argo
Subject: [External] RE: Quicksilver Court, Lot 6 Mfd. Residence - Permit #BLRE-05-20-6269
Attachments: lot6.pdf
Here is the more accurate and current proposed location of modular home. Let me know if this works.
Sorry for the delay
Sent from my Verizon, Samsung Galaxy smartphone
Original message
From: Dave Argo <dargo@garfield-county.com>
Date: 6/2/20 3:11 PM (GMT -07:00)
To: Jody Daniels <ghdgrowit@aol.com>
Cc: Lindsay Krol <Ikrol@garfield-county.com>, Andy Schwaller <aschwaller@garfield-county.com>
Subject: Quicksilver Court, Lot 6 Mfd. Residence - Permit #BLRE-05-20-6269
Jody:
We received the full-size copies of your foundation plan for Quicksilver Court Lot 6 that you dropped off at our office
yesterday.
However, before we can review plans for the Manufactured home on this property we also require that you submit a
site plan with the exact location of this new structure clearly identified. The site plan you submitted is not legible and
simply stating that it's in the same location as the prior stick -built home doesn't exactly cut it. In addition to being
legible, the site plan should be drawn to scale with dimensions/distances from property lines and setbacks clearly
shown. See the attached checklist (page 2) for other requirements.
For your information, please refer to the previously submitted site plan as per Eric Kraii's office for an example of what
we need submitted to our office. Please provide us with (2) copies of a revised site plan for this project.
Thank you for your attention to this matter.
Dave Argo
Plans Examiner
1
• 25 0'
I
;,TBA
3K 628'
'G x703\\\
�ti
r
35.0' EASEMENT
RECEPTION NO.
760053
G
20.0' PUBLIC SERVICE/
COMPANY OF COLORADO
PRIMARY RIGHT -OF --WAY
RECEPTION NO. 772125
Et gineered Septic System:
On -Site Wastewater Treatment System (OWrS) to be inspected
by a Professional Engineer licensed in the state of Colorado.
Provide Engineer's final report prior to final building inspection
& Certificate of Occupancy.
?'151172"W %r
X09.33'
BUILDING
BACK TIE)
LOT 6
436,12610
r.F.
r RE: SEP:1C Ei,IGiNE,MFNG FOR
LOCATION OF SEPTIC SYSTEM
& LEECH FIELD
PROPERTY LINE • •
REMOVED 1N 1.
AMENDED PLAT
•
SITE •2O' IN
FLOOD ?LAN;
ANY RETAININ
4' IN HEIGHT, MEA"' RO
B.O. FOOTING TO WAIL
TO BE ENGINEERED
\
\\As)§
Ci-
(f) p�
�( ANN
iR
1100
ierilz ptAf p1.0,4 poF6
-P
tr
_ • ti 1\
' SUPI' II:D 3` 1.01 :p _
r WELL TO THE SOUTF;)
4-f N90'QO'QOHE---1 ,,.„ ..
155.51'
0.48' 45"W
58.37'
POST TIVEDRAINAGE TO BE
?RESEsii COMPLETELY
NO3'37'3¢"E 755.20'
L27
L28
i
1 Sri :, •
'`�•,(� `
•
a
'o -
20.0' PUBLIC
UTILITY EASEME
RECEPTION NO.
'V • •.� •
1 - FIRE PROTECTION,
A:15
-j
�4
' I
ZI
RECEP
'fit`, _ _ •_rte`r ;��I
RECE_
kEW LOCATION of
PROPERTY LINE.
1
QUICK'. ELER
P Nn
559'56'24"E
84.43'
5Q�6'S3 21 E
169.87/7— /
i
0.4.4,14.,I- ' J: 0y
1 G 6•YL,�s���
Dave Argo
From: Dave Argo
Sent: Tuesday, June 2, 2020 3:12 PM
To: Jody Daniels
Cc: Lindsay Krol; Andy Schwaller (aschwaller@garfield-county.com)
Subject: Quicksilver Court, Lot 6 Mfd. Residence - Permit #BLRE-05-20-6269
Attachments: SFR or Duplex Checklist.pdf; Quicksilver Lot 6.pdf
Jody:
We received the full-size copies of your foundation plan for Quicksilver Court Lot 6 that you dropped off at our office
yesterday.
However, before we can review plans for the Manufactured home on this property we also require that you submit a
site plan with the exact location of this new structure clearly identified. The site plan you submitted is not legible and
simply stating that it's in the same location as the prior stick -built home doesn't exactly cut it. In addition to being
legible, the site plan should be drawn to scale with dimensions/distances from property lines and setbacks clearly
shown. See the attached checklist (page 2) for other requirements.
For your information, please refer to the previously submitted site plan as per Eric Kraii's office for an example of what
we need submitted to our office. Please provide us with (2) copies of a revised site plan for this project.
Thank you for your attention to this matter.
Dave Argo
Plans Examiner
Le Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
Tel: 970-945-8212 Ext. 1610
Email: dargo@garfield-county.com
Web: garfield-county.com
1
Garfield County
Community Development Department
108 8th Street, Suite 401
Glenwood Springs, CO 81601
(970) 945-8212
www.garfield-county.com
SINGLE FAMILY OR DU
BUILDING PERMIT
APPLICATION CHECKLIS
SINGLE FAMILY OR DUPLEX BUILDING PERMIT APPLICATION CHECKLIST
In order to understand the scope of work intended and to expedite the issuance of a permit, it is
important that complete information be provided. Please review this document to determine if you have
adequate information to design your project and to facilitate a plan review.
APPLICATION FORM: Please make sure the following information is provided on the application.
• Parcel number obtained from the County Assessor's Office.
• Job address (assigned physical address)
• Legal Description: block, lot, tract, subdivision, filing, or section, township and range.
• Owner's name, mailing address, phone, fax or cell.
• Contactors name, mailing address, phone, fax, or cell.
• Architect and/or Engineer's name, mailing address, phone, fax or cell.
• Building size, height, number of stories and lot size.
■ Use of building (Residential).
• Class of Work (New, Addition, Alteration, Repair, Demo, Move/ Relocation).
• Detailed description of work.
• Type of heating (natural gas, propane, electric, other).
• Sewer system (Community or OWTS), also see other items below.
• Garage (Attached or Detached).
• Driveway permit (please see other items below).
• Valuation (labor and materials), see attached worksheet.
OTHER ITEMS:
■ If you anticipate obtaining a water -tap from the City of Rifle, please provide a letter indicating that
the City will provide water service. Required to submit building permit application.
• OWTS requires a septic permit application to be submitted with the building permit application.
• A separate electrical permit must be obtained from the State of Colorado Electrical Board.
• At the time of building permit submittal, you are required to show proof of legal and adequate
access to the site. This may include proof of right to use a private easement, County Road &
Bridge permit, or Colorado Department of Highway permit, including a Notice to Proceed. The
County Road & Bridge Department can be reached at 970-625-8601.
• If you anticipate excavating or grading prior to issuance of a building permit, you will be required
to obtain a separate grading permit.
• If you belong to a Homeowners Association (HOA) it is your responsibility to obtain written
approval, if required.
• Provide copies of any Resolutions and/or Land Use Permits associated with this property.
• Additional Dwelling Units may require Administrative Review.
■ A Colorado State Licensed Electrician and Plumber must perform installation and hook-ups,
unless the homeowner is performing the work.
BUILDING PLANS: 2 sets of plans must be submitted. Plans must be 18"x24" minimum size, complete,
identical, legible and to scale. All plans will be checked at the counter for completeness. If any of the
required information is missing, the building permit application cannot be accepted.
SITE PLAN: Please make sure the following information is provided on the site plan.
• Property address/legal description.
• North Arrow and Scale on each page.
• Show all property lines, building envelopes, flood plain and easements.
• Provide setback distances from boundaries, buildings, septic, well and waterways.
• Location and direction of the county or private road and driveway accessing the property.
• Proposed and existing structures. Include sheds, barns, decks, patios, and any other buildings.
• Existing and proposed grade, positive drainage around structure (to be contained on site).
• Streams, rivers, creeks, springs, ponds and ditches.
• Existing and proposed wells, septic tanks, leach fields and other systems (if applicable).
• Retaining walls (engineer stamped detail required for walls over 4 ft., measured from bottom of
footing to top of wall).
NOTE: Any site plan depicting the placement of any portion of the structure within 50 feet of a property
line or not within an established building envelope shall be prepared, stamped and signed by a licensed
surveyor. For structures to be built within a building envelope, provide a copy of the recorded subdivision
final plat with the proposed structure located in the building envelope.
ARCHITECTURAL PLANS: Please provide the following information on the architectural plans.
• Minimum of four (4) elevations (N,S,E,W). Indicate height of building measured from existing
grade to the midpoint between the ridge and eave of a gable or shed roof or to the top of a flat
roof.
• Floor plans for each level, including dimensions and scale noted.
• Clearly label each room or space (bedroom, bath, kitchen, closet, etc).
• Show the location of the mechanical equipment.
• Building cross sections with construction details.
• Window sizes, types and operation noted on the floor plans or elevations.
• Specify roof slope/pitch, roof covering and siding materials.
• Stair and guard details specifying rise, run, height and spacing.
• Attic, roof and crawlspace ventilation details. Indicate size and location of ventilation openings.
• Minimum insulation shown for walls, floors, roofs/ceilings, slabs, basements and crawlspaces.
• Provide stove and fireplace make, model, EPA or Colorado Phase II Certification. Masonry
fireplaces shall be designed to the International Residential Code (IRC) requirements.
STRUCTURAL PLANS: Please provide the following information on the structural plans.
• Design specifications to include roof and deck snow Toad, wind and seismic design and frost
depth.
• Foundation plan showing complete footing and foundation dimensions.
• Footing and foundation details specifying reinforcement and referenced on plans.
• Framing plans for each floor level and roof. All beams, columns, joists, rafters and trusses
specified. Pre -manufactured structures require the engineers stamp, signature and date.
• Framing /connection details, braced wall lines, shear wall schedule, location and hold downs.
NOTE: If any required information is missing, delays in issuing the permit are to be expected. If
determined by the Building Official that additional information is necessary to review the application
and/or plans for compliance, the application may be placed on hold until the required information is
provided. Work may not proceed without the issuance of a permit.
The Building Division will collect a Plan Review fee at time of application submittal. The permit fee, as
well as any Road Impact fees will be collected when the permit is issued.
The permit application must be signed by the owner or by person having written authority from the owner
to act as their representative.
Building cannot be occupied until a Certificate of Occupancy (CO) is issued. Using the building without a
CO will be considered an illegal occupancy and may be grounds for vacating the premises. (Final/CO
inspection requirements will be attached to your approved field set of plans.)
I hereby acknowledge I have read, understand and will abide by the requirements of this
checklist.
Property Owner Print and Sign Date
35.0' EASEMENT
RECEPTION NO.
760053
-25 0'
UIL G
TBA
3K 62
3G 503
20.0' PUBLIC SERVICE
COMPANY OF COLORADO
PRIMARY RIGHT—OF—WAY
RECEPTION NO. 772125
Engineered Septic System:
On -Site Wastewater Treatment System (OWTS) to be inspected
by a Professional Engineer Licensed in the state of Colorado.
Provide Engineer's final report prior to final building inspection
& Certificate of Occupancy.
?'15'02"W
?09.33'
3UILDING
BACK TIE)
PROPERTY LINE
REMOVED IN
\ AMENDED PLAT
LOT
6
jt)f Gv=
. I`
RE: SEPTIC ENGINEERING FOR
LOCATION OF SEPTIC SYSTEM
& LEECH FIELD
SITE NOT IN
FLOOD PLANE
ANY RETAINING WALLS OVER
4' IN HEIGHT, MEASURE FROM
B4O, FOOTING TO T.O. WALL,
TO BE ENGINEERED
POSITIVE DRAINAGE TO BE
PRESENT COMPLETELY
AROUND STRUCTURE PER
'GARFIELD COUNTY SPECS.,
NO3'37'34"E 755.20'
+' (J)
4- \ ,,
4)
.0- U
0 \\-1,,,
N90 50500"E—- \'‘
I.p. b\
I a. \: �\
1
til
i•1 W CISTERN)
SURPUW BY LOT ,'
r wE.E To HE SOUTH)
0'48'45"W
58.37'
20.0' PUBLIC
UTILITY EASEME
RECEPTION NO.
°0 L18 - —L19— — —
I.° ,•
FIRE PROTECTION,
RECEP
v.
4"
RE ER
•9' •• Q•• PQJVO'I
NEW LOCATION OF
PROPERTY LINE,
QUICK IL ER
P.Nn \\
S00'S3 21„E�169.8�
—1—S89'56'24"E
ski 84.43'
i
C