HomeMy WebLinkAboutAs-built Drawings 06.18.2020r 1
Tough engineered plastic
Mil not corrode_
Installs without tools_
leo
DECK/PORCH
DECK/PORCH
Adjustment knob moves
opening up or down in 1/1 b"
increments• total movement
is 7/8".
i
Simple to install, Just
push into any 4" pipe.
1, SCH, 40, SDR 35, and
\1� thin wall.
Water tight fit
POL YL OK PRODUCT DETAIL
5 FOOT SEPTIC
TANK TO BUILDING
SETBACK
CLEAN OUT AT
5' FROM HOUSE
25' TRENCH TO
BUILDING SET BACK /
APPROXIMATE
LOCATION OF
TEST HOLE #2
QUICK4 STANDARD MULTIPORT END CAP
2 '
8.0 l
34 "
Schematic for Permit
and Construction
APPROXIMATE
LOCATION OF
TEST HOLE #1
6SGM
118 West Sixth Street, Suite 200
Glenwood Springs, CO 81601
970.945.1004 www.sgm-inc.com
1250 GALLON SEPTIC TANK
(CONCRETE, PLASTIC
OR FIBERGLASS)
100' LONG INFILTRATOR
TRENCHES (TOTAL OF 5)
PROVIDE 25 CHAMBERS IN EACH
TRENCH. USE QUICK 4 CHAMBERS
AND END CAPS WITH AN
INSPECTION PORT INSTALLED
ON THE FIRST AND LAST
CHAMBER OF EACH RUN.
TRENCHES ARE TO BE
LAID FLAT. (SEE TRENCH SECTIONS
FOR SPECIFIC DEPTH OF BURY)
INSPECTION PORT — TYP.
PROPERTY
L/NE
Lu
10 FOOT
PROPERTY LINE
SETBACK
EXISTING RISER FOR
PUMP ACCESS
•
•
0
Graphic Scale
10 20
40
In Feet: 1" = 20'
INSPECTION PORT — TYP.
INSTALL RISER FOR
PUMP ACCESS
•
NOTE: /T IS RECOMMENDED THAT
POLYLOK (OR EQUAL) FLOW DISTRIBUTION
WEIRS BE INSTALLED ON THE OUTLET
OF EACH PIPE TO THE INFILTRATOR
TRENCHES. IT IS CRITICAL THAT FLOW
IS EQUALLY DISTRIBUTED TO EACH TRENCH
(SEE PRODUCT DETAIL BELOW)
4'' PVC FROM
HOUSE i %FOOT MIN. SLOPE
4
PROVIDE TRAFFIC RATED
LID IF IT IS ANTICIPATED
THAT VEHICLES WILL TRAVEL
OVER SEPTIC TANK
4" SOLID WALL 3034 PVC
PIPE AT 1/4 %FOOT SLOPE (MIN.)
TO DISTRIBUTION BOX
PROVIDE AN
EFFLUENT FILTER
ON DISCHARGE SIDE
OF SEPTIC TANK
° 4
° 4
1250 GAL. SEPTIC TANK
NOT TO SCALE
Garfield County, Colorado
Burkett Residence
Tract 8, Antlers Orchard Development,Silt, CO
INFILTRATOR SYSTEMS INC.
QUICK4 STANDARD CHAMBER
MOUND FOR PROPER DRAINAGE
52"
INSPECTION PORT
\L
TOPSOIL_ , \`
NATIVE BACKFILL
.34 ,,
/6"
ESTABLISH VEGETATIVE COVER
8' MAX BURIAL DEPTH
12" MIN., H-10 LOAD AREAS
6'' MIN., NON —TRAFFIC AREAS
}
12"
QUICK4 CHAMBER
TYPICAL INSTALLATION
DETAIL
(Not to Scale)
PIPE CAP, TYP
4" OBSERVATION PIPE, TYP
EXCAVATION
Revision
Date
By
As Built
6/18/2020
JSS
NATIVE
BACKFILL, TYP
.es
IN —SITU SOIL, TYP
,�I INFILTRATOR QUICK4
; GRAVELLESS CHAMBER
6' MIN
(10' SHOWN)
EXISTING
GRADE 6 " DIA. PVC
PIPE SLEEVE
3'
(TYP)
QUICK4 TRENCH DETAIL
NOT TO SCALE
AS Built
OWTS Design and Details
PRIOR TO FINAL GRADE DETERMINATION OF
DEPTH OF INFILTRATORS, CONTRACTOR TO
EXCAVATE TO THE INTERFACE BETWEEN OVER—
LYING CLAYS TO THE GRAVEL LAYER BELOW
(APPROX.4 TO 5' BELOW GROUND SURFACE)
LOCATE BOTTOM OF INFILTRATORS ON TOP
OF GRAVEL LAYER— LAID FLAT)
NOTE: /F OVER 48" IN DEPTH, PROVIDE
AN AIR VENT TO EACH TRENCH IN LIEU
OF OBSERVATION PORT. AIR VENT TO EXTEND
36" ABOVE ADJACENT FINISH GRADE
Job No. 0000-000.000
Drawn by: KS
Date: 8/06/ 18
QC:
PE: JSS Of
File:
As Built Burkett -BM
1
1