Loading...
HomeMy WebLinkAboutPermit REVISED 06.23.2020Garfield County Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number SEPT -6169 (REVISED) Permit Type X New X Repair X Alteration Issue Date 6/23/2020 Expiration Date 6/23/2021 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: Lot 14, Pinyon Peaks Subdivision, Carbondale, CO 81601 Parcel No. 2393-113-03-014 Owner Name David and Sheila Paulsen Owner Phone (970) 306-9303 Designed By Carla Ostberg with CBO, INC. Designer Phone (970) 309-5259 Contractor Harry Mayer Const. Inc. Contractor Phone (970) 379-2780 Number of Bedrooms 3 Minimum Tank Capacity: 1,000 gallons Minimum Absorption 525 ft2 Permit Conditions: This REVISED OWTS Permit is approved on the condition of compliance with the report and revised design as submitted by CBO, INC. dated June 6, 2020. The previous OWTS Permit SEPT -6169 is null and void. Changes to the revised design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a three bedroom residence and consist of a 1,000 -gallon, two- compartment pre -cast concrete (or poly) septic tank set level and accessible at grade with an effluent filter in the outlet tee of the tank followed by a distribution box set level and to grade at the to distribute effluent to 528 ftz of Soil Treatment Area (STA). The STA consists of four graveliess chamber trenches consisting of 11 Quick4 Infiltrator chambers per trench (44 chambers total). Inspection ports are to be installed at each end of the trenches. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. 'i/p„,-,7 !` v$ 11 &__ 6/23/2020 Issued By: Garfield County Environmental Health Department Date