Loading...
HomeMy WebLinkAboutPermitGarfield County Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number SEPT-6337 Permit Type X New X Repair X Alteration Issue Date 7/06/2020 Expiration Date 7/06/2021 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address TBD Old Ranch Road, Rifle, CO 81650 Parcel No. 2127-343-00-344 Owner Name Alexandra Schwaller Owner Phone 970-274-6337 Designed By Civco Engineering, Inc. Designer Phone 435-789-5448 Number of Bedrooms 3 Minimum Tank Capacity 1 000 gallons Minimum Absorption 1,080 ft2 Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design as submitted by Civco Engineering, Inc. dated June 12, 2020. Changes to the revised design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a three bedroom residence and consist of a 1,000-gallon, two - compartment septic tank set level and accessible at grade with an effluent filter in the outlet tee of the tank followed by a distribution box set level and to grade to distribute effluent to 1,080 ft2 of Soil Treatment Area (STA). The STA consists of two mounded beds consisting of two laterals per trench surrounded by 11-inches of washed rock per bed. Each bed will be 45-feet by 12-feet, with the two beds separated by a minimum distance of 18 feet center to center. Distribution laterals within the beds will be separated by a minimum of 6 feet. Inspection ports are to be installed at the corners of each bed, between the beds, and at the end of one of the laterals per bed. Maintain all setbacks and elevations as designed. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction, and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. .. 9 //f� K- e-✓ . K 7/06/2020 Issued By: Garfield County Environmental Health Department Date