HomeMy WebLinkAboutPermitPublic Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT -6412
Permit Type X WIN X Repair X Alteration
issue Date 8/06/2020 Expiration Date 8/06/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address 4972 CR 113 Carbondale, CO 81623 Parcel No. 239312302005
Owner Name Aaron Natoniewski Owner Phone 970-948-0713
Designed By Carla Ostberg
Contractor Aaron Natoniewski
Designer Phone 970-309-5259
Contractor Phone 970-948-0713
Number of Bedrooms 3 + 1 Minimum Tank Capacity 1500 gallons Minimum Absorption 700 ft2
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, Inc. dated June 30, 2020. Changes to the revised design and permit must be
approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve an existing 3 -bedroom residence and a proposed 1 -bedroom detached
accessory dwelling unit (ADU). A 1,500 -gallon two-compartment septic tank with a pump in the
second compartment will be set level with access to grade. Effluent will be pumped to an automatic
distributing valve set level with access to grade distributing effluent to 720 ft2 of STA. The STA will
consist of two chamber beds, each with four rows of six ARC 36 Low Profile chambers for a total of
48 chambers. Inspection ports are to be installed in each corner of each chamber bed. Maintain all
setbacks and elevations as designed, including a minimum distance of 50 feet between water course
and OWTS components.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
•
71/ !�
8/05/2020
Issd By. Garfield County Environmental Health
Department
Date