HomeMy WebLinkAboutPermitCGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT -6311
Permit Type X New X Repair X Remodel/addition
Issue Date 7/13/2020 Expiration Date 7/13/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address 420 Pinon Paint Glenwood Springs, CO 81601 Parcel No. 239305305011
Owner Name Jack Czaika
Designed By All Service Septic
Owner Phone
773-653-0932
Designer Phone 970-309-5259
Contractor Jack Czaika Contractor Phone 773-653-0932
Number of Bedrooms 4 Minimum Tank Capacity 1250 gallon Minimum Absorption 656.25 sq. ft.
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the revised report and design as
submitted by All Service Septic dated July 1, 2020 based on Soil Type R-0. Changes to the design and
permit must be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a four-bedroom residence and consist of a 1500 gallon septic tank with a
pump in the second compartment set level and accessible at grade followed by an automatic
distributing valve set level and to grade to distribute effluent to 663 sq. ft. of STA. The STA consists
of two separate 6.5' x 51' pressure -dosed GeoMat beds with at least 6 -feet of undisturbed soil
between each bed. A minimum of 3 -feet of sand filter material will be installed using secondary sand
media. Laterals will be spaced 2 feet from the edges of the bed and 2.5 -feet apart with flushing
valves at the end of each lateral and inspection ports at each corner of the bed. Maintain all setbacks
and elevations as designed.
Contact the designer and Garfield County Public health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
(cko----,A__----
7/+3 /a0&0
Issued By: Gar field County Environmental Health
Department
Date