1. DESIGN CONTOURS NOT SHOWN PER EXEMPTION FOR PIPELINES: THE SITE PLAN DOES
NOT NEED TO SHOW TOPOGRAPHIC CONTOURS IF THE INSTALLATION OF PIPELINE WILL
NOT RESULT IN CHANGES TO THE SURFACE GRADE.
2, UTILITIES AND PIPELINES SHOWN HEREON HAVE BEEN DETERMINED BY A PRECURSORY
SURFACE INSPECTION OF THE INSTALLATION SITE. UTILITY ANO PIPELINE DEPTHS ARE NOT
SHOWN, OTI IER UTILITY CROSSINGS AND ENCROACHMENTS MAY EXIST. CONTRACTOR
SHALL BE RESPONSIBLE FOR LOCATING AND PROTECTING ALL BURIED UTILITIES AND
PIPELINES WITHIN TI IE WORK AREA. CONTRACTOR SHALL CONTACT TI IE LOCAL UTILITY
LOCATION AGENCY OR SERVICE (UTILITY NOTIFICATION CENTER OF COLORADO.
VVWW.UNCCLORG, CALL 811 OR PHONE 1-800-922-1987) NOT LESS THAN TWO WORKING
DAYS PRIOR TO STARTING TRENCHING. EXCAVATION WORK IN THE PROJECT AREA.
3, THE APPLICABLE PROVISIONS AND REQUIREMENTS PRESCRIBED BY 29 CFR 1928.650
THROUGH 1926.652 AND APPENDIXES A THROUGH F (SUBPART P EXCAVATIONS) SHALL BE
HELD IN STRICT COMPLIANCE IN THE PERFORMANCE OF WORK SHOWN HEREON,
4. PIPELINE MARKERS SHALL BE PLACED. DIRECTLY ABOVE THE INSTALLED PIPELINE
CERTIFICATE OF ENGINEER
TRUOI 6, MORREY STATES THAT SHE ISA PROFESSIONAL ENGINEER EMPLOYED BY WILLIAMS
BARGATH LLC TO PREPARE AN EXHIBIT FOR A GRADING PERMIT APPLICATION AS SHOW ON
THIS DRAWING. THAT THE WORK COMMENCING ON APRIL 13. 2020. WAS PERFORMED UNDER
HER SUPERVISION AND RESPONSIBLE CHARGE; THAT CHANGES TO THE SURFACE GRADE ARE
NOT ANTICIPATED; THAT THE DESIGN 16 16 ACCORDANCE WITH THE NORMAL AND CUSTOMARY
PRACTICES FOR THIS TYPE AND NATURE OF PROJECT; THAT DESIGN OF THE PIPELINE IS NOT
INCLUDED OR INTENDED TO BE CERTIFIED; AND THE DESIGN AS SHOWN IS TO THE BEST OF MY
KNOWLEDGE AND BELIEF SUFFICIENT AND ADEQUATE FOR THE INTENDED PURPOSES OF
ACQUIRING PERMITS AND COMMUNICATING REQUIREMENTS TO CONSTRUCTION PERSONNEL
TRW! K MORREY
COLORADO PROFESSIONAL ENGINEER NO 49943
– SITE PLAN–
SCALE: 1" = 100'
CONSTRUCTION WORK SPACE
CONSTRUCTION DISTURBANCE
PIRELFNE EASEMENT
PERMANENT ROW DISTURBANCE
C/L PROPOSED ROW
CIL EXISTING ROW
C/L PROPOSED 6" BY-PASS
FROJECTAREA
!PERMANENT ROW
EXISTING DISTRUBANCE
NEW DISTURBANCE
MEM
!CONSTRUCTION WORK SPACE WM=
TOTAL AREA OF DISTURBANCE =EMM
- •
„.•
2'
Glover -
'
3
(1,(V -t.•;,-.
4,1 ;
-• •
\••••••• \
1.2
Ai A-rpaccicEr—
i
.7
no.
9
?" Tre9sier mesa
I IL \
.20 I I
087
LAT- ol.r.ArL4r
LON: 107 88918' W
NAD63/WGS64
16
•
\ N. r
'L\ \ •
"%.
(- I
-ts"
15
66681
8.•
19
2[1
Sharrard 21
32
- •-
WM"
•
-
tuft"
' •
4 31
02101
co E"
12
Ths B14W
'
- 33
.01/.1Pit INGLE
AMU pomas •
NORTH IVIAMH PEAK -
RIFLE
,..RL'LLLSON
-- •
7/
– VICINITY MAP–
SCALE: 1"= 2000'
ir/ V./
(27
27
1 •
6)
1; m C6n ST.. BOTC.ri..
MFFiN & ASSOCIATES, wa
24" BARGARTH GATHERING PIPELINE
wIIt
AREA MAP'
DISTURBANCE AREA
TABLE OF ACREAGES AND SQUARE FOOTAGE
Lim.LBAPLHOWN
DRG -AREA MAP -22050
JOON., 29014
510. 21, res., R.94 W, GARFIELD COUNTY, COLORADO