HomeMy WebLinkAboutPermitPublic Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT -6451
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 09/04/2020 Expiration Date 09/04/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable.
Project Address: Tract 37, Antlers Orchard, Silt, CO 81652 Parcel No.: 2127-363-00-003
Owner Name: Zane and Paige Haderlie
Owner Phone: (970) 618-4775
Designed By: Capstone Enterprises West, LLC Designer Phone: (970) 250-3331
Contractor: J. Caliber Construction Designer Phone: (970) 314-0489
Number of Bedrooms _3 Minimum Tank Capacity 1,000 -gallon Minimum Absorption 1,080
ft2
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the application and design
documents as submitted by Capstone Enterprises West, LLC. dated June 21, 2020 and the conditions
indicated below. Changes must be approved by Garfield County Public Health and the designer prior
to construction.
The OWTS will serve a three-bedroom residence. The system will consist of a 1,000 -gallon two
compartment septic tank set level with access to grade and an effluent filter in the outlet tee,
followed by a distribution box set level with access to grade to distribute effluent to 1,116 square
feet of Soil Treatment Area (STA). The STA consists of 4 rows of 23 Infiltrator Quick4 chambers per
row (92 total) in a bed configuration. Maintain all setbacks and elevations as designed.
CONDITIONS OF APPROVAL, TO BE CONSTRUCTED IN THE FIELD
1. The infiltrative surface shall be constructed level;
2. inspection ports shall be provided at each corner of the bed;
3. An effluent filter shall be provided in the outlet tee of the second chamber of the septic
tank; and,
4. A cleanout shall be provided between the residence and the septic tank.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the;ystem will be issued.
../ -; r'i k 7✓ " 7L s
9/04/2020
I sued By: Garfield County Environmental Health
Department
Date