HomeMy WebLinkAboutObservation of Excavation 05.13.20201(4-A Kumar & itaseetatse,, LS8. • Geotechnical and Materials Engineers and Environmental Scientists 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.cam An Employes Owned Company www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado May 13, 2020 James Gornick Building Specialists Attn: Jim Gomick 1005 Cooper Avenue Glenwood Springs, Colorado 81601 jgornick 1988tar7,gmaii.com Subject: Dear Jim: Project No. 20-7-264 Observation of Excavation, Proposed Garage, 278 Rippy Lane, Garfield County, Colorado As requested, a representative of Kumar & Associates, Inc. observed the excavation at the subject site on May 7, 2020 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were performed in accordance with our agreement for professional engineering services to James Gornick Building Specialists, dated May 6, 2020. The proposed garage will be a single story structure with a footprint of approximately 55 feet by 44 feet. Two overhanging awning areas will be built off of the garage on the south and east sides and supported on isolated pads. Ground floor will be slab on grade. Spread footings placed on the natural soils and sized for an assumed allowable bearing pressure of 2,500 psf were designed for the foundation support. At the time of our visit to the site, the foundation excavation had been cut in 1 level from 2 to 3 feet below the adjacent ground surface. The soils exposed in the bottom of the excavation consisted of very stiff clay. Results of swell -consolidation testing performed on samples taken from the site, shown on Figure 1, indicate the soils are slightly compressible under existing moisture conditions and light loading and possess a low expansion potential when wetted. The laboratory testing is summarized in Table 1. No free water was encountered in the excavation and the soils were slightly moist to moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 2,500 psf can be used for support of the proposed garage. The exposed soils tend to expand when wetted and there could be some post -construction movement of the foundation if the bearing soils become wet. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose disturbed soils in footing areas should be removed and the bearing level extended down to the undisturbed natural soils. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 12 feet. Foundation walls acting as retaining James Gornick Building Specialists May 13, 2020 Page 2 structures (if any) should also be designed to resist a lateral earth pressure based on an equivalent fluid unit weight of at least 55 pcf for on-site soil as backfill. A perimeter foundation drain should not be needed for the proposed shallow footing and slab -on -grade construction. The onsite soils, exclusive of topsoil, can be used to support lightly loaded slab -on -grade construction with movement risk mainly if the bearing soils are wetted. Structural fill placed within floor slab areas can consist of the on-site soils compacted to at least 95% of standard Proctor density at a moisture content near optimum. Surface grading to encourage drainage and prevent ponding is necessary to prevent wetting of the bearing soils and decrease the risk and magnitude of foundation movement. Backfill placed around the structure should be compacted and the surface graded to prevent ponding within at least 10 feet of the building. Landscape that requires regular heavy irrigation, such as sod, and sprinkler heads should not be located within 10 feet of the foundation. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, K.uniar,& Associates. Inc„ James H. Parsons Reviewed by: Steven L. Pawl JHP/kac attachments Fig Table 1 solidation Test Results iry of Laboratory Test Results Kumar & Associates, Lon, :catj\0.cn n0,2a724 Tg SAMPLE OF: Clay FROM: Southwest Corner WC = 18.4 %, DD = 103 pcf CONSOLIDATION - SWELL CONSOLIDATION - SWELL — 3 1 — 4 1 0 — 2 — 3 4 EXPANSION UNDER CONSTANT PRESSURE UPON WETTING 1.0 APPLIED PRESSURE — KSF 10 TMw Iwel n..ul4 appy nN/ to 11.. epnpiee 'Looted. The I.nklop Maar! erwe nol be rupn,duceo, s.ofpl N foe. without the approval of *Una], ontl nOMOIclos, Inc. Swell Gpneailaailen I0AY.p performed In accordance with ASTM 12-4548. 10 SAMPLE OF: Clay FROM: Southeast Corner WC = 18.8 %, DD = 99 pcf EXPANSION UNDER CONSTANT PRESSURE UPON WETTING 1.0 APPLIED PRESSURE — KSF 10 100 20-7-264 Kumar & Associates SWELL—CONSOLIDATION TEST RESULTS Fig. 1 1(±A Kumar & Associates, Inc..® Geotechnical and Materials Engineers and Environmental Scientists SAMPLE LOCATION BOTTOM OF EXCAVATION Northwest Corner NATURAL MOISTURE CONTENT () 25.5 TABLE 1 SUMMARY OF LABORATORY TEST RESULTS GRADATION SAND (%) NATURAL DRY GRAVEL DENSITY (pct) 93 PERCENT PASSING NO. 200 SIEVE 96 ATTERBE RG LIMITS LIQUID LIMIT PLASTIC INDEX (%) UNCONFINED COMPRESSIVE STRENGTH (PSF) 4,100 Clay Project No. 20-7-264 SOIL OR BEDROCK TYPE 1 Southwest Comer 18.4 103 Clay Southeast Comer 18.8 99 Clay