Loading...
HomeMy WebLinkAboutPermitGarfield County Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number SEPT-6490 Permit Type X New X Repair X Remodel/addition X Tank only Issue Date 9/24/2020 Expiration Date 9/24/2021 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address_160 Gemat Ct. Rifle, CO 81650 Owner Name Casecam, LLC/ John Blatz Designed By CBO, Inc / Carla Ostberg Contractor Clearwater Const. Mgmt Parcel No. 217711103004 Owner Phone 970-379-3709 Designer Phone 970-309-5259 Contractor Phone 970-379-3709 Number of Bedrooms 0 Minimum Tank Capacity 1,000 Minimum Absorption 210 ft2 Permit Conditions: This OWTS Permit is approved on the condition of compliance with the application and design documents as submitted by CBO, Inc. dated 8/20/2020 and updated 9/24/2020. Changes must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a proposed metal shop. A 1,000-gallon two -compartment septic tank with an effluent filter in the outlet tee will be set level with access to grade. Effluent will gravity flow to a distribution box set level with access to grade distributing effluent to 216 ft2 of STA. The STA will consist of two chamber trenches, each with 9 Infiltrator 'Quick 4' Standard Plus chambers for a total of 18 chambers. Inspection ports are to be installed in each end of each trench. Schedule 40 (or stronger) sewer line must be installed under all areas subject to traffic. The well was not drilled at the time of the design. Maintain all setbacks and elevations as designed, including minimum distances between system components and the proposed well and minimum distance to the dry gulch and stormwater drainage infrastructure. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of theystem will be issued. / ) /r' Vic, f r�r, tr' =- 9/24/2020 Issued y `Garfield County Environmental Health Department Date