HomeMy WebLinkAboutPermitGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT-6490
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 9/24/2020 Expiration Date 9/24/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address_160 Gemat Ct. Rifle, CO 81650
Owner Name Casecam, LLC/ John Blatz
Designed By CBO, Inc / Carla Ostberg
Contractor Clearwater Const. Mgmt
Parcel No. 217711103004
Owner Phone 970-379-3709
Designer Phone 970-309-5259
Contractor Phone 970-379-3709
Number of Bedrooms 0 Minimum Tank Capacity 1,000 Minimum Absorption 210 ft2
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the application and design
documents as submitted by CBO, Inc. dated 8/20/2020 and updated 9/24/2020. Changes must be
approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a proposed metal shop. A 1,000-gallon two -compartment septic tank with
an effluent filter in the outlet tee will be set level with access to grade. Effluent will gravity flow to a
distribution box set level with access to grade distributing effluent to 216 ft2 of STA. The STA will
consist of two chamber trenches, each with 9 Infiltrator 'Quick 4' Standard Plus chambers for a total
of 18 chambers. Inspection ports are to be installed in each end of each trench. Schedule 40 (or
stronger) sewer line must be installed under all areas subject to traffic. The well was not drilled at
the time of the design. Maintain all setbacks and elevations as designed, including minimum
distances between system components and the proposed well and minimum distance to the dry
gulch and stormwater drainage infrastructure.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of theystem will be issued.
/ )
/r' Vic, f r�r, tr' =-
9/24/2020
Issued
y `Garfield County Environmental Health
Department
Date