HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-09-20-6480
CUC Construction
New Single -Family Residence
28 Eagle Claw Circle, Glenwood Springs
Ironbridge PUD — Phase 2, Lot 251
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (IRC)
AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC).
2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY BUILDING REQUIREMENTS.
REDLINED NUMERICAL NOTATIONS ON PLANS REFER TO ANNOTATED ITEMS ON THE
ATTACHED "RESIDENTIAL PLAN REVIEW LIST".
3) A LOT IMPROVEMENT CERTIFICATE WET -SEALED BY A COLORADO LICENSED SURVEYOR
IS REQUIRED AT UNDERGROUND PLUMBING INSPECTION TO VERIFY COMPLIANCE WITH
APPLICABLE BUILDING CODE FIRE SEPARATION REQUIREMENTS INCLUDING DISTANCE
OF WALLS, ROOF OVERHANGS & EXTERIOR OPENINGS FROM PROPERTY LINE.
4) ONE-HOUR FIRE-RESISTANT CONSTRUCTION IS REQUIRED AT EXTERIOR WALLS,
UNDERSIDE OF ROOF OVERHANG SOFFITS AND EXTERIOR OPENING PROTECTION AT
DOORS & WINDOWS WITHIN FIVE (5) FEET OF PROPERTY LINE AS PER I.R.C., TABLE
R302.1(1) AND AS REDLINED ON PLANS.
5) GEOTECHNICAL ENGINEER TO PROVIDE OPEN -HOLE INSPECTION REPORT VERIFYING
1,500 P.S.F. BEARING CAPACITY REQUIREMENT. PROVIDE ENGINEER'S SEALED
APPROVAL REPORT AT UNDERGROUND PLUMBING INSPECTION PRIOR TO INITIAL
CONCRETE POUR.
6) STRUCTURAL ENGINEER SHALL BE RESPONSIBLE FOR REVIEW AND INSPECTION OF
STRUCTURAL CONCRETE MAT SLAB FOUNDATION INCLUDING: PLACEMENT OF STEEL
REINFORCING BARS, ANCHOR BOLTS AND FORMWORK. PROVIDE ENGINEER'S SEALED
APPROVAL REPORT (WET STAMPED & SIGNED) FOR BUILDING INSPECTOR REVIEW AT
UNDERGROUND PLUMBING INSPECTION.
7) IF APPLICABLE, CONTACT BUILDING DEPARTMENT PRIOR TO CONCRETE POUR TO
SCHEDULE SPECIAL INSPECTION TO VERIFY PLACEMENT OF RIGID INSULATION IF IT WILL
BE SUBSEQUENTLY CONCEALED FROM VIEW.
8) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD.
ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REQUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.