HomeMy WebLinkAboutSoil Compaction Report 09.25.2020'�±� Kumar & Associates, Inc. Geotechnical and Materials Engineers and Environmental Scientists �� kumarusa.com Glenwood Springs 5020 County Road 154 Glenwood Springs, CO 81601 Phone: 970-945-7988 Soil Compaction Report Test Method: ASTM D 6938 Client: Doolen Construction 3838 County Road 243 New Castle, CO 81647 Project: 20-7-343.A Lot 32, Pinyon Mesa Pinyon Mesa, Cliffrose Way Carbondale, CO 81623 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) In Place Wet Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%) Optimum Moisture Tolerance (%) Remark 16 9/25/20 327-20 B (D698) ML 16.0 105.6 15.0 108.3 124.6 6 103 98 -1 / 3 DP/MP 17 9/25/20 327-20 B (D698) ML 16.0 105.6 15.7 104.5 120.9 8 99 98 -1 / 3 DP/MP 18 9/25/20 327-20 B (D698) ML 16.0 105.6 15.1 108.7 125.1 8 103 98 -1 / 3 DP/MP 19 9/25/20 327-20 B (D698) ML 16.0 105.6 18.1 103.6 122.3 8 98 98 -1 / 3 DP/MP Test Information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 16 Structural Fill: 8' north 1' east of southwest corner At footing grade Troxler / 3440 / 24902 / 5/28/2020 Rubi Araiza 17 Structural Fill: 20' east of northwest corner At footing grade Troxler / 3440 / 24902 / 5/28/2020 Rubi Araiza 18 Structural Fill: Bearing pad 4' below grade Troxler / 3440 / 24902 / 5/28/2020 Rubi Araiza 19 Structural Fill: Back of garage- 15' west of east corner 4' below grade Troxler / 3440 / 24902 / 5/28/2020 Rubi Araiza Remarks Comments DP/MP: Density Pass / Moisture Pass Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. This report presents opinions formed as a result of our observations of soil compaction. We have relied on the contractor to continue applying the recommended compactive effort and moisture to the fill during times when our observer is not observing operations. Tests are made of the soils only as believed necessary to calibrate our observer's judgement. Test data are not sole basis for opinions on whether the soils meets specifications. These test results only apply to the samples which were tested. The testing report shall not only be reproduced, except in full, without the written approval of Kumar and Associates, Inc. Nuclear gauge density testing performed in accordance with ASTM D6938. Page 1 of 1