OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT 19-5873 (Building Q)
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 09/08/2020 Expiration Date 09/08/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable.
Project Address: 0062 County Road 113, Carbondale, CO 81623 Parcel No.: 2393-181-00-359
Owner Name: Rudd, LLC
Owner Phone: (970) 309-0123
Designed By: Zancanella and Associates, Inc. Designer Phone: (970) 945-5700
Contractor: Rudd Construction Designer Phone: (970) 309-0123
Minimum Tank Capacity 1,000 -gallon Minimum Absorption 2,400 ft2
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the application and design
documents as submitted by Zancanella and Associates, Inc. dated August 20, 2020. Changes must be
approved by Garfield County Public Health and the designer prior to construction.
The OWTS will serve a four -bay warehouse commercial building, with a toilet and sink in each unit.
The system will consist of a 1,000 -gallon two compartment septic tank set level with access to grade,
followed by a 2,000 -gallon septic tank with a pump in the second chamber of the tank with access to
grade to distribute effluent to 2,448 square feet (64 feet by 36 feet) of Soil Treatment Area (STA).
The STA consists of an unlined sand filter, utilizing "Secondary Sand Media". Minimum sand depth is
24 -inches, with distribution laterals encased in 12 -inches of 1.5 -inch screened gravel. Maintain all
setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
�`
3/ 1-V----1,1 1. C
9/08/2020
Issued By: Garfield County Environmental Health
Department
Date