Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLCO-07-19-5872 and SEPT-07-19-5873 Rudd, LLC Factory Warehouse — Building Q 62 County Road 113 (Cattle Creek Road), Carbondale 1) ALL WORK SHALL COMPLY WITH THE FOLLOWING: 2015 I.B.C., I.M.C., I.P.C., I.F.G.C., I.F.C., AND 2009 I.E.C.C. AS WELL AS MANUFACTURER'S INSTALLATION REQUIREMENTS. 2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY'S BUILDING REQUIREMENTS AND INSPECTIONS POLICIES. 3) ALL WORK TO COMPLY WITH "COMMERCIAL LIMITED" ZONE DISTRICT REGULATIONS AS PER GARFIELD COUNTY'S LAND USE & DEVELOPMENT CODE. WORK SHALL ALSO COMPLY WITH ON - SITE WASTEWATER TREATMENT SYSTEM REQUIREMENTS. 4) BUILDING APPROVED AS OCCUPANCY GROUP F-1: "MODERATE -HAZARD FACTORY INDUSTRIAL" AND CONSTRUCTION TYPE V-B. THE MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE & COMBUSTIBLE MATERIALS SHALL BE PER I.B.C., SECTIONS 413 & 414, AND THE MAXIMUM ALLOWABLE QUANTITIES OF HAZARDOUS MATERIALS PER I.B.C., TABLE 307.1(1). 5) THIS BUILDING IS APPROVED FOR CORE & SHELL CONSTRUCTION ONLY, AND ANY SUBSEQUENT TENANT IMPROVEMENTS WILL REQUIRE ADDITIONAL BUILDING PERMITS. INTERIOR PARTITION WALLS SEPARATING INDIVIDUAL TENANTS TO COMPLY WITH "FIRE PARTITION" REQUIREMENTS AS PER SECTION 708. 6) CONTACT LOCAL FIRE DISTRICT TO REVIEW I.F.C. REQUIREMENTS. FINAL APPROVAL REPORT FROM FIRE DISTRICT IS REQUIRED PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY. 7) OPEN -HOLE SOILS REPORT IS REQUIRED AT FOOTING INSPECTION, 2000 P.S.F. 8) WALK DOOR REQUIRED FOR EGRESS FROM EACH TENANT SPACE. PROVIDE 36" X 80" MIN. SIZE PER I.B.C., SECTION 1010.1. LOCKS, LATCHES AND LANDINGS PER I.B.C., SECTION 1008. VERIFY EXIT DIRECTIONAL SIGNAGE PRIOR TO ELECTRICAL ROUGH -IN INSPECTION. 9) ALL EGRESS DOORS SHALL MEET ICC/ANSI A117.1-2009 FOR ACCESSIBILITY. LOCKS, LATCHES & LANDINGS PER I.B.C., SECTION 1008. VERIFY EXIT DIRECTIONAL SIGNAGE PRIOR TO ELECTRICAL ROUGH -IN INSPECTION. 10) BUILDING SHALL COMPLY WITH ACCESSIBILITY REQUIREMENTS AS PER I.B.C., CHAPTER 11 & ICC/ANSI A117.1- 2009, INCLUDING PARKING, SITE ACCESS, ENTRANCES AND BATHROOMS. BATHROOM FACILITIES SHALL MEET MINIMUM REQUIREMENTS FOR SIZE, FIXTURE LAYOUT, CLEARANCES, ETC. 11) BATHROOM INTERIOR FINISHES (INCLUDING FLOOR, WALLS AND BASE) SHALL HAVE A SMOOTH, HARD, NON -ABSORBENT SURFACE AND TO OTHERWISE COMPLY WITH I.B.C., SECTION 1203 "TOILET AND BATHROOM REQUIREMENTS". 12) LIGHT & VENTILATION PER I.B.C., CHAPTER 12. 13) ELECTRICAL PERMITTING & INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD. ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED AT FRAME INSPECTION, AND FINAL APPROVAL IS REQUIRED PRIOR TO FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.