HomeMy WebLinkAboutEngineered Building Specs 09.02.2020BUILDINGS Sept 02, 2020 Peak Steel Buildings PO Box 1275 Madison, GA 30650 Re: Job No.: 6758-23822 Preferred Transportation 375 County Road 352, Ste 1040 Rifle, CO 81650 Garfield WRF 50'-0" W x 60'-0" L x 16'-0" EH Roof Slope 2.0:12 To whom it may concern: In our professional opinion, the above referenced buildings have been designed to sustain no less than the requested design loads as listed on the order documents, applied per the 2015 International Building Code specifically as follows: Risk Category Dead Load Collateral Load Sprinkler Load Roof Live Load Ground Snow Load Roof Snow Load Wind Speed Veit (3-sec gust) 120 mph Wind Speed Vasd 93 mph Serviceability Wind Speed 76 mph Internal Pressure Coefficient ±0.18 II - Normal Metal Building Only 1.0 psf (Lights) 0.0 psf 20.0 psf Reducible 47.0 psf Importance Factor Is = 1.0 40.0 psf Thermal Factor Ce = 1.2 Exposure = C Exposure = 1.0 Slope Factor Cs = 1.0 Wind design is based on an Enclosed building. All building envelope accessories (windows, doors, etc.) not provided by the metal building fabricator must be designed to sustain no less than the same wind criteria as the building. For components, cladding, and MWFRS, deflections involving wind are based on 10-year serviceability wind pressures. Seismic Importance Factor le = 1.000 Spectral Response Acceleration, Ss = 0.307 Spectral Response Acceleration, Si = 0.080 Seismic Design Category = B Seismic Response Coefficient, Cs = 0.1061 Design Spectral Response, SDS = 0.3181 Design Spectral Response, So, = 0.1280 Site Class = D Design Base Shear, V = 4.60 (Lat) kips = 4.56 (Long) kips Page 1of2 Seismic Force -Resisting System H. Steel Systems not Specifically Detailed for Seismic Resistance Framing Direction Lateral Longitudinal Response Modification Factor 3.0 3.0 Deflection Amplification Factor 3.0 3.0 Analysis Procedure Equivalent Lateral Force Other Loads: None Design is in accordance with the 2012 AISI North American Specification for the Design of Cold -Formed Steel Structural Members, the 2010 AISC Specification for Structural Steel Buildings, the AWS D1.1-10 Structural Welding Code - Steel, the AWS D1.3-08 Structural Welding Code - Sheet Steel, and generally accepted engineering practices. The engineer whose seal and signature appears on these documents represents Whirlwind Steel Buildings, Inc and is not the Engineer of Record (EOR) for the overall construction project. It is expressly noted that this letter of professional opinion includes only the steel building as designed and furnished by the metal building fabricator, and specifically excludes all accessories, anchor rods, foundation, masonry, general contract work, or any field modifications deviating from the metal building system construction documents. Sincerely, Mustapha Chreeide, PE Sep 15, 2020 Page 2 of 2