HomeMy WebLinkAboutSub-excavation & Structural Fill 09.05.2018CTL I THOMPSON I N C O R P O R A TED September 5, 2018 Tom Provost P.O. Box 1128 Carbondale, CO 81623 Subject: Sub -excavation and Structural Fill Provost Residence Lot 53-B, Panorama Ranches Garfield County, Colorado Project No. GS06219.000 CTL 1 Thompson, Inc. performed a geotechnical investigation for the Prov- ost Residence under this project number (report dated April 17, 2018). An alter- native that we recommended was to subexcavate the natural soils below the building to a depth of at least 3 feet and moisture -treat and replace the excavated soils as densely -compacted, structural fill. During excavation operations, we visited the site to observe the bottom of the sub -excavated area below the planned building. Subsequently, CTL/Thompson, Inc. observed and tested structural fill during placement. In our opinion, the structural fill is in general conformance with project specifications and suitable for support of footings and floor slabs for the residence. We appreciate the opportunity to work with you on this project. If you have questions or we can be of further service, please call. Very truly yours, CTL 1 THOMPSON, INC. \[�J .fir Jes D. Kellogg, P.E ■'vision Manager JDK:ac cc: Via email to blkmagicweldino sorris.net 234 Center Drive 1 Glenwood Springs, Colorado 81601 Telephone: 970-945-2809 Fax: 970-945-7411 CTL l THOMPSON Compaction Testing Report #: SNG-000007 812412018 Report Date: 8127/2018 Test Method: ASTM D 6938 Glenwood Springs 234 Center Drive Glenwood Springs. CO 81501 Phone: 970-945.2800 Client: Tom Provost P.O. Box 1128 Carbondale, CO 81623 Project: GS06219.000F-345 Provost Residence Garfield County, CO Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min Comp. (%) Remark 23 8/24/18 Curve No, 2 698C Granular 8.5 132.0 4.3 133.3 8 101 98 D 24 8/24/18 Curve No, 2 698C Granular 8.5 132.0 4.5 133.0 8 101 98 b 25 8/24/18 Curve No, 2 698C Granular 8.5 132.0 4.2 134.4 8 102 98 0 26 8/24/18 Curve No, 2 698C Granular 8.5 132.0 4.4 134.1 8 102 98 0 Test information Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 23 Structural Fill: grid lines 8.5/1.5 0.0 below bottom of footing XPLORER /3500 / 1995 / 4/1 31201 7 Thibault, Sandon 24 Structural Fill: grid fines A.2/1.9 _ 0.0 below bottom of footing XPLORER / 3500 / 1995 / 4/13/2017 Thibault, Sandon 25 Structural Fill: grid tines C.114 0.0 below bnitorn of fooling XPLORER/ 3500 / 1995 / 4/13/2017 Thibault. Sandon 26 Structural Fill: grid lines D.5/1.5 0.0 below bottom of footing XPLORER / 3500 / 1995 / 4/13/2017 Thibault. Sandon Remarks Comments D: Test result is considered acceptable with no moisture requirement. Tests are "Direct Transmission° (Method Aj unless probe depth is noted as SackSCatter'. Gauge calibration data on Cita wit the testing agency. 26: The contractor had completed the structural fell placement below footings and Footing pads. density tests results are satisfactory. A rock correction was applied to the above density tests. This report presents opinions formed as a result of our observations of fill placement and the test results shown above. Test data are not the sole basis for opinions whether the fill meets project specifications. The contractor is responsible to apply necessary compaction effort and moisture to comply with project specifications . Our test results, observations and opinions do not constitute acceptance of the work. Page 1 of 1