Loading...
HomeMy WebLinkAboutInterior Lighting Compliance Certificate 10.09.20201 (ift COMcheck Software Version 4.1.4.1 interior Lighting Compliance Certificate Project Information Energy Code: Project Title: Project Type: 2015 IECC Aspen Glen New Construction Construction Site: Owner/Agent: Designer/Contractor: Carbondale CO Additional Efficiency Package(s) Reduced interior lighting power. Requirements are implicitly enforced within interior lighting allowance calculations. Allowed Interior Lighting Power A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B X C) 1-Dining: Bar Lounge/Leisure 3570 0.91 3245 Proposed Interior Lighting Power A Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast 1 Dining: Bar Lounge/Leisure LED 1: LT-100: Other: LED 2: LT-101: Other: LED 3: LT-102: Other: LED 4: LT-103: Other: LED 5: LT-104: Other: LED 6: F: Other: LED 7: G: Other: LED 8: H: Other: LED 9: J: Other: LED 10: K: Other: Total Allowed Watts = 3245 B C D E Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. 1 10 8 75 1 3 38 112 1 3 68 202 1 1 60 60 1 1 45 45 1 21 11 225 1 6 21 126 1 6 11 65 1 1 60 60 1 1 60 60 Total Proposed Watts = 1030 Interior Lighting PASSES: Design 68% better than code Interior Lighting Compliance Statement Compliance Statement: The proposed interior lighting design represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application. The proposed interior lighting systems have been designed to meet the 2015 IECC requirements in COMcherk Version 4.1.4.1 and to comply with any applicable mandatory requirements listed in the Inspection Checklist. Jack Shattuck Name - Title Signature 10/9/2020 Date Project Title: Aspen Glen Report date: 10/09/20 Data filename: \\Filesol\shares\Projects\05066 - Club Corp\05066.44 - Aspen Glen\11-ComCheck\Blackstone G Page 1 of 5 Electrical Comcheck.cck COMcheck Software Version 4.1.4.1 rift Inspection Checklist Energy Code: 2015 IECC Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section & Req.ID C103.2 [PR4]1 Plan Review Plans, specifications, and/or calculations provide all information with which compliance can be determined for the interior lighting and electrical systems and equipment and document where exceptions to the standard are claimed. Information provided should include interior lighting power calculations, wattage of bulbs and ballasts, transformers and control devices. Complies? ®Complies ❑Does Not ❑Not Observable ❑Not Applicable Comments/Assumptions C406 k Plans, specifications, and/or [PR9]1 :calculations provide all information with which compliance can be :determined for the additional energy efficiency package options. Complies ❑Does Not ['Not Observable; ENot Applicable [ 11 Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Aspen Glen Report date: 10/09/20 Data filename: \\Filesol\shares\Projects\05066 - Club Corp\05066.44 - Aspen Glen\11-ComCheck\Blackstone C. Page 2 of 5 Electrical Comcheck.cck Section # & Req.ID Rough -In Elec!crical Inspection Complies? Comments/Assumptions C405.2.1 [EL15]1 Lighting controls installed to uniformly reduce the lighting load by at least 50%. ElComplies •Does Not ❑Not Observable ■Not Applicable C405.2.1 !Occupancy sensors installed in [EL18]1 i required spaces. I ®Complies In Does Not ['Not Observable ❑Not Applicable C405.2.1, C405.2.2. 3 (EL23]2 Independent lighting controls installed per approved lighting plans and all manual controls readily accessible and 'visible to occupants. G ®Complies ❑Does Not ❑Not Observable •Not Applicable C405.2.2. 1 [EL22]2 lAutomatic controls to shut off all building lighting installed in all buildings. ®Complies ❑Does Not ❑Not Observable Not Applicable C405.2.3 [EL1O ;Daylight zones provided with individual controls that control the lights independent of general area• lighting. •Complies •Does Not Not Observable FA Not Applicable C405.2.3, C405.2.3. C405.2.3.1, 2®Not [EL20]1 Primary sidelighted areas are equipped with required lighting controls. ■Complies I■Does Not Not Observable Applicable C405.2.3, C405.2.3. 1, C405.2.3. 3 [EL21]1 Enclosed spaces with daylight area under skylights and rooftop monitors are equipped with required lighting• controls. ❑Complies ❑Does Not Not Observable Not Applicable C405.2.4 [EL4]1 Separate lighting control devices for specific uses installed per approved lighting plans. f''IComplies •Does Not •Not Observable ❑Not Applicable C405.2.4 [EL8]1 Additional interior lighting power allowed for special functions per the approved lighting plans and is automatically controlled and separated from general lighting. ®Complies •Does Not •Not Observable ❑Not Applicable C405.3 [EL6]1 Exit signs do not exceed 5 watts per face. ®Complies ❑Does Not •Not Observable •Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Aspen Glen Report date: 10/09/20 Data filename: \\Files0l\shares\Projects\05066 - Club Corp\05066.44 - Aspen Glen\11-ComCheck\Blackstone C Page 3 of 5 Electrical Comcheck.cck Section # & Req.ID Final Inspection Complies? Comments/Assumptions C303.3, C408.2.5. 2 [FI17]3 Furnished O&M instructions for systems and equipment to the building owner or designated . representative. •Complies ❑Does Not Not Observable ■Not Applicable C405.4.1 [F118]1 ;Interior installed lamp and fixture I lighting power is consistent with what is shown on the approved lighting plans, demonstrating proposed watts are less than or equal to allowed I watts. .CDComplies ISee the Interior Lighting fixture schedule for values. •Does Not Not Observable •Not Applicable C408.2.5. i Furnished as -built drawings for 1 ielectric power systems within 90 days [F116]3 !of system acceptance. •Complies •Does Not Not Observable ■Not Applicable C408.3 Lighting systems have been tested to [F133]1 .ensure proper calibration, adjustment, k programming, and operation. f •Complies ■Does Not ®Not Observable ■Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Aspen Glen Data filename: \\Files0l\shares\Projects\05066 - Club Corp\05066.44 - Aspen Glen\11-ComCheck\Blackstone C. Page 4 of 5 Electrical Comcheck.cck Report date: 10/09/20 Project Title: Aspen Glen Report date: 10/09/20 Data filename: \\Files0l\shares\Projects\05066 - Club Corp\05066.44 - Aspen Glen\11-ComCheck\Blackstone C Page 5 of 5 Electrical Comcheck.cck