Loading...
HomeMy WebLinkAboutPermitGarfield County Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number SEPT -6580 Permit Type X New X Repair X Remodel/addition X Tank only Issue Date 11/20/2020 Expiration Date 11/20/2021 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: 831 County Road 237 Silt, CO 81652 Parcel No.: 212736300073 Owner Name: Ryan and Stephani Rose Designed By: WestWater Engineering Contractor: J Caliber Construction Owner Phone: (970) 319-9536 Designer Phone: (970) 241-7076 Contractor Phone: (970) 314-0489 Number of Bedrooms: 2 Minimum Tank Capacity: 1,000 -gallon Minimum Absorption: 600 ft2 Permit Conditions: This OWTS Permit is approved on the condition of compliance with the application, report, and design documents as submitted by Westwater Engineering, Inc. dated October 2020. Changes must be approved by Garfield County Public Health and the designer prior to construction. The proposed OWTS will serve a two-bedroom ADU. The system consists of a new two-compartment 1,000 -gallon septic tank followed by a distribution box to distribute effluent to 612 ft2 of STA. The septic tank and distribution box are to be set level with access brought to grade. The STA consists of three chamber trenches with 17 Quick4 Infiltrator chambers per trench (51 chambers total). Minimum slopes of sewer and effluent pipes in Section 4.0 of the design report shall be followed. Inspection ports are to be installed at the terminal end of each trench. Contact Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed components. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. /2 i r-61 11/20/2020 Issued By: Garfield County Environmental Health Department Date