HomeMy WebLinkAboutPermitGarfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT -6580
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 11/20/2020 Expiration Date 11/20/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 831 County Road 237 Silt, CO 81652 Parcel No.: 212736300073
Owner Name: Ryan and Stephani Rose
Designed By: WestWater Engineering
Contractor: J Caliber Construction
Owner Phone: (970) 319-9536
Designer Phone: (970) 241-7076
Contractor Phone: (970) 314-0489
Number of Bedrooms: 2 Minimum Tank Capacity: 1,000 -gallon Minimum Absorption: 600 ft2
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the application, report, and
design documents as submitted by Westwater Engineering, Inc. dated October 2020. Changes must
be approved by Garfield County Public Health and the designer prior to construction.
The proposed OWTS will serve a two-bedroom ADU. The system consists of a new two-compartment
1,000 -gallon septic tank followed by a distribution box to distribute effluent to 612 ft2 of STA. The
septic tank and distribution box are to be set level with access brought to grade. The STA consists of
three chamber trenches with 17 Quick4 Infiltrator chambers per trench (51 chambers total).
Minimum slopes of sewer and effluent pipes in Section 4.0 of the design report shall be followed.
Inspection ports are to be installed at the terminal end of each trench.
Contact Garfield County Public Health at least 48 hours prior to requesting final inspection of the
installed components.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
/2 i r-61
11/20/2020
Issued By: Garfield County Environmental Health
Department
Date