HomeMy WebLinkAboutOWTS Designa- �r r 0 0 N MAINTENANCE NOTES . TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE OWTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING: 1.A. MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK. 1.B. MINIMIZE SOLIDS GOING DOWN THE DRAIN. 1.C. ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D. MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. 1.E. USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. 1.F. KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. 1.G. AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.H. DO NOT USE LYE -BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN -OFF, OR OTHER STRONG CLEANING AGENTS. 1.1. DO NOT PUT ANY "ROOT DETERRENTS" DOWN THE DRAIN. 1.J. DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN 1,K. MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2. THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM SITE EVALUATION 1. SITE AND SOIL EVALUATIONS WERE PERFORMED BY. DERIC J, WALTER, PE JAMES D. KELLOGG, PE BOUNDARIES UNLIMITED INC. CTL-THOMPSON, INC. 923 COOPER AVE, STE 201 GLENWOOD SPRINGS, CO 81601 970.945.5252 --'711NECTA 11n; 234 CENTER DR. GLENWOOD SPRINGS, CO 81601 970.945.2809 2. EVALUATION DATE(S): MAY, 2020 AND JULY 2020. 3. SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=525 GPD: 3.A. SPRING OR WELL=100' 3.B. POTABLE WATER SUPPLY LINE=25' 3.C. POTABLE WATER SUPPLY CISTERN=25' 3.D. DWELLING=20' 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 3,G. LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H. DRY GULCH, CUT BANK OR FILL AREA=25' 3.1. SEPTIC TANK=5' 3.J. RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) 3. SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): 3.A. SPRING OR WELL=50' 3.B. POTABLE WATER SUPPLY LINE=10' 3.C. POTABLE WATER SUPPLY CISTERN=25' 3.D. DWELLING=5' 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH =10' 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' 3,G. LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' 3.H. DRY GULCH, CUT BANK OR FILL AREA=10' 3.1. STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. 4' PVC WYE SOIL EVALUATION 1. PER THE SOILS ANALYSIS BY CTL-THOMPSON, INC., SOILS ARE TYPE 2A WHICH HAS AN LTAR OF 0.50 GPD/SF. 2, GROUNDWATER WAS ENCOUNTERED AT A DEPTH OF 5-FEE IN THE PIT (P-3) NORTHEAST OF THE PROPOSED SOIL TREATMENT AREA. GROUNDWATER WAS NOT ENCOUNTERED IN THE PROPOSED LOCATION NEAR PIT (P-1) OR IN PIT (P-2) JUST BELOW THE PROPOSED LOCATION. SURFACE TOPSOIL / SILT LOAM AND LOAM SOILS "/ (WEAK TO STRUCTURELESS) TYPE 2A i� Site & Soils Evaluation Scale: N.T.S. FINISH GRADE 4"0 PVC RISER 4"0 SEWER LINE Cleanout Scale: N.T.S. •p ry,I1411J T7I' r; rANOU-AI THE Hill rIiJC CDPEL APPROVLL Z OOU-GALLON- PRECAST CONCRETE THREE ni CHAMBER SEPTIC TANK WITH A SIPELE I DOSING ASSEMBLY (SEE DET iI_) SUIT_ I HI ,AThd.AEEA OCATIONS OF THE TANK, PIPE AND SOIL REATMENT AREA MAY VARY PROVIDED AT MINIMUM SETBACKS ARE MAINTAINED EE THE SETBACK REQUIREMENTS IN THE SITE EVALUATION" NOTES DETAIL. GENERAL ABSORPTION AREA NOTES 1. INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. ABSORPTION BEDS SHALL NOT EXCEED 12' WIDE BY 100-FEET IN LENGTH, SHALL PARALLEL THE TOPOGRAPHY AND SHALL BE INSTALLED IN A RECTANGULAR PATTERN WHENEVER POSSIBLE. 3. THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 4"0 PVC SOLID PIPE CUT TO FIT 4"0 COUPLING (UNION). USE A HOLE SAW TO CUT OUT CIRCLE OFF THE CENTER OF THE UNIT 4"0 PERFORATED PVC PIPE. EXTEND PIPE TO REST ONS BOTTOM OF THE BED `, IN-ERMU TENT IRRIGATION LATERAL II.oP'E:TI0N PORT T"I' iLLrDETAIL) DE IRIP UPON NIANIFOL(I ;EALII ENE)) 4. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 5. NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. 1'1/4-GROUNDWATER WAS ENCOUNTERED AT 5'± IN PIT (P-3) r ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE AREA TO WITHIN 0.1'±. (TYP.). IF NECESSARY TO ACHIEVE THIS SURFACE, IMPORT CONCRETE SAND TO USE AS LEVELING MATERIALO. REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY SAND OR SANDY GRAVELS. DO NOT USE COMPACTED MATERIALS. -PRCH' : PE NP -INTERMITTENT IRRIGATION I ATERAL. THE DITCH MUST BE PIPED IF THE STA CANNOT EL INSTALLED AT LEAST 25' AWAY FROM THE DITCH. TO SURVEY BENCHMARK: '' NE 1/16 CORNER SECTION 24 SET 31/4" ALUM, CAP L.S.#19598 ON 3/4" ALUMINUM BAR E_EV:5581.89' 6. UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE EXCAVATION. 7. TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED DRAINAGE SYSTEMS BIODIFFUSER (STANDARD), OR ENGINEER APPROVED EQUAL INSTALL A 12"Wx24"L SPLASH BLOCK BELOW EACH INLET PIPE Pressure Dosing Chamber Bed Scale: N.T.S. 1EE SOIL IRL0IM5N AREA - IS GREATER THAN 100' AWAY FROM THE WELL (WELL TO THE SOUTHEAST) SEPTIC TANK & DOSING SYSTEM NOTES. 1. SYSTEM TO BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2, THE SYSTEM SUPPLIER SHALL PROVIDE THE OWNER WITH AN OPERATIONS AND MAINTENANCE MANUAL WHICH INCLUDES A MAINTENANCE SCHEDULE. 3. THE DOSING SYSTEM SHALL BE CONNECTED TO AN ALARM WHICH SHALL BE BOTH AUDIBLE AND VISIBLE, LOCATED NEAR A RESIDENCE AND ON A CIRCUIT SEPARATE FROM THE PUMP. 4. TANK DIMENSIONS ARE BASED ON A VALLEY PRECAST, INC. 2,000 GALLON TOTAL VOLUME THREE -COMPARTMENT TANK WITH A 300 SERIES DOSING SIPHON (ITEM #1500T-3CP-F-D3). 5. THE DOSING SIPHON ASSEMBLY SHALL BEAN ORENCO MODEL 312 (12" DRAWDOWN) PRODUCING A VOLUMETRIC DOSE OF APPROXIMATELY 120-130 GALLONS (4-5 DOSES PER DAY). COVER WITH 6" OF TOPSOIL AND REVEGETATE - FILL OVER THE CHAMBERS WITH UNCOMPACTED WELL GRADED LOCAL SOILS. To Sill ce, S TE To New Cast! SYSTEM NOTES 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH COLORADO DEPARTMENT OF PUBLIC HEALTH & ENVIRONMENT (CDPHE) REGULATION 43-ONSITE WASTEWATER TREATMENT SYSTEMS (OWTS), MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWTS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE ENGINEER MUST OBSERVE THE CONSTRUCTED SYSTEM BEFORE BACKFILL AND PROVIDE A LETTER OF INSPECTION AS REQUIRED BY THE LOCAL AGENCY. A REQUEST FOR INSPECTION MUST BE MADE BY THE CONTRACTOR AT LEAST 48-HOURS PRIOR TO THE EXPECTED TIME OF BACKFILLING. 2. DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A. FOUR (4) BEDROOM RESIDENCE USING TREATMENT LEVEL 1 (TLl ). 2.B. AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD5): 23.1. SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BOD5 lbs/day 2.B.2. ADWF = 75 gpd * (3 BEDROOMS * 2 PERSONS/BEDROOM + 1 BEDROOM * 1 PERSON) =525 gpd 2.8.3. BOD5 = 0.20 lbs/day * (3 BEDROOMS * 2 PERSONS/BEDROOM + 1 BEDROOM " 1 PERSON) = 1.40 lbs/day BOD5 mg/L=BODS*1,000,000=1.40Ibs/day"1,000,000= 319.74 mg/L ADWF*8.34 525 gpd*8.34 2.6.4. CBOD5 = BOD5 * 0.85 = 272 mg/L 3. SEPTIC TANK (SEC.43.9.B.2,a): 3.A. MINIMUM REQUIRED TANK SIZE: 1,250-GALLONS (TABLE 9-1). 3.8. SIPHON DOSING IS PROPOSED FOR SOIL TREATMENT AREA REDUCTION AND TO IMPROVE GROUNDWATER PROTECTION. 3.C. INSTALL A 2,000-GALLON THREE (3)-COMPARTMENT TANK WITH A DOSING SIPHON ASSEMBLY IN THE 3RD COMPARTMENT. 3.D. THE TANK IS NOT SUBJECT TO BUOYANCY. 4. SOIL TREATMENT AREA CALCULATIONS A. SOILS WERE ANALYZED BY CTL THOMPSON, INC. (JULY 2, 2020; PROJECT NO. GS06406.000-132) WITH A LONG TERM ACCEPTANCE RATE (LTAR) OF 0.50 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL). 4.B. THE SOIL TREATMENT AREA CONTAINS SLOPES LESS THAN 20%. 4,C, MINIMUM SOIL TREATMENT AREA, STA: STA = ADWF = 525 = 1050 S.F. LTAR 0.50 gpd/S.F. 4.D. SIZE ADJUSTMENT FACTORS: SIPHON DOSED GRAVITY BED = 1.1; CHAMBERS = 0.7 4.D,1. STA, adj = 1050 SF * 1.1 * 0.7 = 808.5 SF 4.E. GRAVELLESS CHAMBER SYSTEM: 4.E.1. INFILTRATOR QUICK4: 808.5 SF/ 12 SF/UNIT = 68 UNITS IN BED CONFIGURATION. 4.E.2. ADS BIODIFFUSER (STANDARD): 808,5 SF/ 17.94 SF/UNIT = 46 UNITS IN A BED CONFIGURATION (USE 48). 5. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITES OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM, 6. CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9. INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 5-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10. SITE PLAN INFORMATION PROVIDED BY HIGH COUNTRY ENGINEERING, INC. (PROJECT NO.2091621). LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 1500 Gallon Top Seam 1500T-3CP-F-03 Filter & 300 Series Siphon �I (2000 Gallon Total Volume) DESIGN NOTES • Design per performance test per ASTM C1227 • Top surface area 87.75 ft2 • fc CO 28 days; concrete = 6,000 PSI Min. Installation: • Tank to be set on 5" min. sand bed or pea gravel • Tank to be bockfilled uniformly on all sides in lifts less than 24" and mechanically compacted • Excavated material may be used for backfill, provided large stones are removed • Excavation should be dewatered and tank filled with water prior to being put in service for installation with water table less than 2' below grade • Meets C1644-06 for resilient connectors • Inlet and Outlet identified above Pipe • Delivered complete with internal piping • Battery Counter Panel with Float • Mount Panel on post next to tank and backfill • 4' Maximum bury depth ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH FILL 1'-0" 3'-O" 2'-O" 4'-a" DRY /20" Clear Access 'CP reen 1/4"0 HOLE NEAR THE CAP Digging Specs Invert Dimensions 15' Long x B' Wide Inlet Outlet Length 56" below inlet Top View Section View Siphon: • Removable screens optional Capacity Net Weight Width Height Inlet Side Middle Outlet Total Lid Tank Total 56" 23" 162" 78" 65" 1016 and 505 gal 507 gal 2028 gal 5420 lbs 16240 lbs 21710 lbs VALLEY ROAST Phone: 719.395.6764 Fax: 719-395-3727 Website: www.vaiieyprecastcom Email: frontdesk©valleyprecastcom .'Bo Civil Engineering y Surveying rt & 1Beyond ct 6 -Or rO . it e cilIIIL' 923 ooper Ave., Ste. 201 Glenwood Springs, CO 81601 (T)970.945.5252 www.bu-inc.com Subsurface Utility Engineering (SUE) Required Project: NO If "Yes", SUE Certification by: Firm: N/A Job #:N/A Date: N/A Engineer or Surveyor Seal Client Information: Dustin & Charity Carnahan 1575 Balsam Ct Rifle, CO 970.319.0141 NORTH 0 2040' it Scale: = 20' t - wwiiat'st,=„At Call before you dig. Garfield County, Colorado Carnahan Residence Revision Date z += N .i v vi CO PC OS ci PROJECT NO. Sheet 20009 Designer: dw Drafter: djw Date: //'_� 1 V• I 8/24/20 File Name: 20009-v-rope.dwg