Permit Number SEPT-6586
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 11/25/2020 Expiration Date 11/25/2021
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: Lot 28 Callicotte Ranch Carbondale, CO 81623 Parcel No.: 239324306028
Owner Name:
Designed By:
Keila Vaenzuela
Boundaries Unlimited, Inc.
Contractor: Valenz Construction
Owner Phone: (970) 987-2509
Designer Phone: (970) 945-5252
Contractor Phone: (970) 456-6483
Number of Bedrooms: 4 Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 735 ft`
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design and
revised drawings as submitted by Boundaries Unlimited, Inc. on November 24, 2020. Changes to the
design and permit must be approved by Garfield County Public Health and the designer prior to
construction.
The new OWTS will serve a new four -bedroom residence. The system will consist of a new, two -
compartment 1,250-gallon septic tank set level with access to grade with an effluent filter in the
outlet tee. Effluent will gravity flow to a distribution box set level with access to grade distributing
effluent to 756 ft` of STA. The STA will consist of three trenches, each with 21 'Quick 4' Infiltrator
chambers for a total of 63 chambers. Inspection ports are to be installed at each end of each trench.
Maintain all setbacks and elevations as designed.
Per the letter from Kumar & Associates, dated October 27, 2020, Kumar and Associates should be
contacted to verify the soils exposed in the septic field at the time of excavation, prior to
installation of the chambers. Verification of the soils as Sil Type 2A shall also be submitted to
Garfield County Environmental Health prior to installation of the chambers.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
Issued By: Garfield County Environmental Health
Department
11/25/2020
Date