Loading...
HomeMy WebLinkAboutPermitGarfield Country 1 Public Health Garfield County Public Health 2014 Blake Ave. Glenwood Springs, CO 81601 Phone: (970) 945-6614 ext. 8150 OWTS PERMIT KEEP AVAILABLE AT PROJECT SITE Permit Number SEPT-6586 Permit Type X New X Repair X Remodel/addition X Tank only Issue Date 11/25/2020 Expiration Date 11/25/2021 For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable Project Address: Lot 28 Callicotte Ranch Carbondale, CO 81623 Parcel No.: 239324306028 Owner Name: Designed By: Keila Vaenzuela Boundaries Unlimited, Inc. Contractor: Valenz Construction Owner Phone: (970) 987-2509 Designer Phone: (970) 945-5252 Contractor Phone: (970) 456-6483 Number of Bedrooms: 4 Minimum Tank Capacity: 1,250-gallon Minimum Absorption: 735 ft` Permit Conditions: This OWTS Permit is approved on the condition of compliance with the report and design and revised drawings as submitted by Boundaries Unlimited, Inc. on November 24, 2020. Changes to the design and permit must be approved by Garfield County Public Health and the designer prior to construction. The new OWTS will serve a new four -bedroom residence. The system will consist of a new, two - compartment 1,250-gallon septic tank set level with access to grade with an effluent filter in the outlet tee. Effluent will gravity flow to a distribution box set level with access to grade distributing effluent to 756 ft` of STA. The STA will consist of three trenches, each with 21 'Quick 4' Infiltrator chambers for a total of 63 chambers. Inspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations as designed. Per the letter from Kumar & Associates, dated October 27, 2020, Kumar and Associates should be contacted to verify the soils exposed in the septic field at the time of excavation, prior to installation of the chambers. Verification of the soils as Sil Type 2A shall also be submitted to Garfield County Environmental Health prior to installation of the chambers. Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final inspection of the installed system prior to backfill. Agreement All installations must comply with all requirements of the Garfield County OWTS regulations including but not limited to the conditions specified above. In consideration of the issuance of the permit, the applicant hereby agrees to comply with all laws and regulations related to the zoning, location, construction and erection of the proposed OWTS and associated structures for which this permit is granted. The applicant further agrees that if the above said regulations are not fully complied with in the zoning, location, erection and construction of the above described OWTS and structure, the permit may then be revoked by notice from the Health Department and immediately become null and void. The issuance of a permit and specifications of terms and conditions therein will not constitute assumption of liability, nor create presumption that the local public health agency or its employees may be liable for the failure or malfunctioning of any system. Permit issuance will not constitute a certification that the system, the equipment used in the system, or any component used for system operation will ensure continuous compliance with the provision of the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit. Permit Approval Plans and specifications for the proposed OWTS have been reviewed and are considered satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from the date of issuance unless construction on the system has commenced. An "as -built" drawing must be submitted and inspection of the system must be completed by GCPH before final approval of the system will be issued. Issued By: Garfield County Environmental Health Department 11/25/2020 Date