HomeMy WebLinkAboutOWTS Design Plan 12.09.2020G:\2020\30201-ALBRIGHT\CIVIL\CIVIL DWGS\DE\30201-DE-OWTS PLAN.DWG - Dec 09, 2020 - 2:08pm 58231'51 'iv-, 757.43' - 1111. 4 * - * 126,825.5 SQ. F� PROPER,-y _ * LINE TY _ lir 2.91 ACRES r GENERAL NOTES: OWTS SYSTEM NOTES 1. THE OWTS AS SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY SOPRIS ENGINEERING. 1. ALL MATERIALS AND INSTALLATION SHALL CONFORM TO STATE AND COUNTY ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATIONS. 2. THE PROPOSED LOT CONDITIONS BY OWNER. 2. FIELD LOCATIONS OF UTILITIES PRIOR TO CONSTRUCTION AND EXCAVATION.COMPANIES FOR 3. THE EXISITNG LOT CONDITIONS PER COUNTY GIS DATA BASE, AERIAL MAPPING AND SURVEY INFORMATION FROM LILC, BY TUTTLE SURVEY SERVICES 7-8-20. 3. ALL SEWER LINES TO BE SDR-35 BEDDED IN CLASS 6, SDR-26 BEDDED IN SCREENED NATIVE 4. PROJECT TITLE: 17352 HIGHWAY 82 PROFESSIONAL OFFICE OR SCHEDULE 40 P.V.C. PIPE BEDDED IN SCREENED NATIVE MATERIAL UNLESS NOTED OTHERWISE. 5. PRIMARY OWNER NAME & ADDRESS: RFLANDCO LLC 402 PARK AVENUE, UNIT A 4. INSTALL A TWO-WAY CLEAN OUT ON THE SERVICE LINE FROM THE HOUSE. BASALTC0816215. THE CONTRACTOR SHALL ENSURE ALL SEWER LINES AND SEPTIC TANKS ARE WATERTIGHT. 6. LEGAL SUMMARY: Section: 32 Township: 7 Range: 87 A TR IN LOT 18. 2.91 ACRES ANY POTENTIAL PLUMBING LEAKS SHALL BE REPAIRED TO AVOID EXCESSIVE WATER ENTERING THE SEPTIC SYSTEM. 7. SITE ADDRESS: 17352 82 HWY, CARBONDALE, CO 81623 • INSTALL 3-COMPARTMENT 1,500-GALLON CONCRETE SEPTIC TANK I� _ •(VALLEY PRECAST ITEM # 1500t-3CP-HH) * ZONING RURAL INSTALL WITH (2) 24" DIA. BY 24" DEEP RIBBED PVC RISERS WI LIDS AT THE y SURFACE. INSTALL ORENCO SIMPLEX EFFLUENT PUMP ASSEMBLY. . 6. THE SEPTIC TANK SHALL BE INSTALLED LEVEL ON COMPACTED EARTH. INSTALL WATERTIGHT 8. PARCEL NUMBER: 2391-321-00-043 RISERS AS NECESSARY TO BRING ALL REQUIRED ACCESS POINTS TO THE FINISHED SURFACE GRADE. 9. NEW GARFIELD COUNTY OWTS PERMIT #: ISSUED (PVU57-1819-L) W/P300511 PUMP), WI 1.5" DISCHARGE ASSEMBLY IN 500-GALLON 3RD COMPARTMENT DOSING CHAMBER.. DEPTH TO TOP OF TANK FROM PROPOSED GRADE IS APPROX. 2'. RECOMMENDED LOCATION OF OWTS PUMP CONTROL BOX INSTALL PUMP CONTROL BOX IN LINE OF SITE WITH TANK ELECTRICIAN TO PROVIDE CIRCUITS & WIRES FOR PUMPS • a _ 7. A SANITARY BAFFLE TEE IS REQUIRED ON THE SEPTIC TANK INLET AND OUTLET. INSTALL THE 10.PREVIOUS CURRENT OWTS PERMIT: UNKOWN NO FILE FOUND INLET AND OUTLET TEES PLUMB AND IN A POSITION TO ALLOW EASY INSPECTION AND MAINTENANCE OF TANK FROM THE TANK RISERS. 11. CONTRACTOR: w I- Q a DESIGNED BY DRAWN BY CHECKED BY PRESSURE DOSE TRANSPORT PIPE. USE 1.25 SCHD-40 WI & CONTROLS TO CONTROL PANEL. ELECTRICIAN TO CONFIRM WIRE GAUGE SIZE & COORDINATE INSTALLATION dille 8. AN EFFLUENT FILTER IS REQUIRED. INSTALL A 4" EFFLUENT FILTER WITH THE TANK OUTLET SANITARY TEE OF THE SEPTIC TANK OR APPROPRIATE FILTER SYSTEM WITH A DISCHARGE 3.0' MIN. DEPTH OF BURY. BED PIPE WI CL-6 ROAD BASE. INSTALL AT MIN. 2.5% TO ALLOW DRAIN BACK TO TANK. WITH PUMP SUPPLIER/ INSTALLER. EXISTING- 17352 Highway 82 Professional Office, Garfield County, CO Remodel Residential units, PUMP ASSEMBLY. THE GRAVITY OR PUMP SYSTEM FILTER SHOULD BE INSPECTED EVERY SIX ONSITE WASTEWATER TREATMENT SYSTEMS (OWTS) MONTHS. THE EFFLUENT FILTER SHALL BE MAINTAINED AND CLEANED WHEN THE TANK IS Cl) \ Job No. 30201.01 Parcel No. 2391-321-00-043 _ 1 INSTALL UNDERGROUND ELECTRICAL & CONTROL DIRECT BURY UV WIRES OR WIRES IN CONDUIT FOR WOOD 10'X201 \ PERIODICALLY PUMPED OR AS NECESSARY. INSTALL A SUITABLE EXTENSION ON THE FILTER WITH A HANDLE TO BE WITHIN 6" BELOW THE ACCESS LID. Z Design Calculations OWTS PUMPS WITHIN SEWER PIPE TRENCH & CONTROLS. = GARDEN SHED \ _ 1.25" PRESSURIZED MANIFOLD PIPE. PP_. - IN NI 2-WAY CLEAN OUT I ; 9. THE TREATMENT BED MUST BE MARKED AND PROTECTED TO PREVENT DAMAGE FROM The existing residential structure has 4 bedrooms and detached garage structure that can be considered VEHICULAR AND LIVESTOCK TRAFFIC. THE BED SURFACE MUST BE SODDED OR for use as a 1-bedroom ADU. In order to ensure adequate OWTS capacity for existing usage and potential RE-VEGETATED WITH GROUND COVER.THE TREATMENT FEILD SURFACE MUST BE CROWNED Is ^ - MIMS i. ..D-11- _ # INSTALL 4" RISER PIPE INSPECTION PORT WI CAP AT EACH CORNER OF THE BED (TYP.) EXTEND 4" PIPE FROM TOP OF CHAMBER TO MIN.3"ABOVE FINISH GRADES. ) 1/ _1/11/ I � w II /IIIiiiii///: Pt; •,0,, future usage the new replacement system is designed for for the maximum design flow under anticipated TO DIVERT SURFACE DRAINAGE AWAY FROM THE BED. re-development scenarios. The residential facilitydesign assumes a 4-bedroom single familyresidence g g plus a 1-bedroom detached ADU. From County adopted State Regulation 43: 10. THE DIMENSIONS SHOWN ON THE PLAN INDICATE MINIMUM AREA AND SEPARATION DISTANCES FOR THE OWS COMPONENTS. THE BED SHALL BE LEVEL WITH DISTRIBUTION Flow Criteria: Minimum population based on 2 person per bedroom for the first 3 bedrooms = 6 PIPES INSTALLED FOR EQUAL PRESSURE DISTRIBUTION. VIII"c,�1=II VIII -.Design ""_ II==IIII /11111113� persons and 1 bedroom for each additional bedrooms = 4 bedroom residence for a total of 711. F ■ persons. 75 ga%person %dar THE TREATMENT BED SHALL BE CONSTRUCTED WITH CHAMBER UNITS PLACED OVER THE IIII Max. Design flow (Qd)gallons/day = (# of x (avg. flow)gal/person/day.SPECIFIED SAND LAYER FOR USE AS SPRAY SHEILDS. THE CHAMBERS, SAND AND ABSORPTION/TREATMENT PRESSURE DOSED SAND FILTER BED USE USE 33 QUICK-4 IN 3 ROWS WITH 16 CHAMBERS PER ROW FORA TOTAL ABSORPTION AREA OF 840 S.F. THE CHAMBERS SHALL BE INSTALLED AT LEVEL GRADE. .. " 4" GRAVITY SoEWER PIPE INSTAL 2/o � _= .dmtll��)�����) +II�IIIIIIIIIII("••--••••,,,rll)�IO��))��� yl IIIIIIII III IIIIIIIII�I��II(11IIIIII IIlila people) Design flow Qd1 Main house Residential: 7 persons @ 75 gpd = 7 x 75 = 525 gpd DISTRIBUTION PIPES SHALL BE COVERED WITH FILTER FABRIC TO THE SIDES OF THE Design flow Qd2 ADU a Residential: 2 persons @ 75 gpd = 2 x 75 = 150 gpd EXCAVATION. THE BOTTOM OF THE BED TO BE EXCAVATED TO MIN. DEPTH OF 3.5 FEET WITHIN THE NATIVE GRAVELY LOAMY SAND & BACKFILLED WITH A MINIMUM 24-INCH SAND FILTER LAYER. INSTALL WITH A MIN. 12" NATIVE BACKFILL COVER OVER TOP OF CHAMBERS. SEPTIC FIELD FINISH SURFACE APPROX. 6" ABOVE ADJACENT GRADES.Septic - dl 11 1- 1lmute� fig ' ,� LI a y PROPOSED HOU Y Y L / AD 12. THE MINIMUM COVER OVER THE TOP OF THE CHAMBER SPRAY SHIELD UNITS SHALL BE 12 Design flow Qd = Qd1 +Qd2 = 525 + 150 = 675 gpd INCHES NOT TO EXCEED 18". Tank Design: 2-Day detention time = 675 x 2 = 1350 gallons required. 502 MAIN STREET CARBONDALE, CO 81623 (970)704-0311 FAX: (970)-704-0313 A A 70' = J 0 r ` „1' it Use a 1,500 gallon, three-compartment septic tank with a bio-tube dosing assembly in the third chamber. 13. THE BED CHAMBERS WILL BE BACKFILLED TO THE SURFACE WITH EXCAVATED MATERIAL VOID OF ROCKS. THE BACKFILL MATERIAL SHALL NOT EXCEED 3" DIAMETER. A MINIMUM 4" DEPTH OF TOPSOIL IS TO BE PLACED ABOVE THE BACKFILL TO THE FINISH SURFACE GRADE. 1 1/4" PVC SCHD-40 CUSTOM PERFORATED PIPE DISTRIBUTION LATERALS. DRILL 5/32-INCH _ "" EXISTI,N• Sub Surface Conditions and Testing: DIA. ORIFICES EVERY 3.0-FEET ALONG THE PIPE & PLACE ON THE TOP OF THE ABSORPTIVE SAND SURFACE. USE WIRE STAPLES TO SECURE PRESSURE PIPE TO SAND SURFACE. ORIENT ORIFICES BETWEEN THE FIRST AND LAST TO SPRAY UPWARD (12 O'CLOCK) AGAINST '�I- H ' /INTERIOR 14. BALL VALVES (SIZE PER PLAN) SHALL BE INSTALLED ON THE TERMINAL ENDS OF THE Subsurface soil investigations and USDA soil texture method tests were performey Sopris EngineeringOC d bon November 27, 2020. The soils in the area of the proposed absorption field were sampled andPERFORATED DISTRIBUTION PIPE JUST BELOW THE 4" INSPECTION PORTS. OF CHAMBERS. DRILL FIRSTAND LAST 5/32" ORIFICES ORIENTED DOWNWARD AT /INJ EXISTING SPRING BOXii .presence of any limiting soil or hydrological conditions, appropriate hydraulic loading rate, absorptive MANUFACTURES INSTALLATION INSTRUCTIONS. level level design for in-situ The surface capacity and to assess appropriate treatment the native soils. soils below nil to 3 inches of topsoil consist of medium dense gravelly sandy loam to sandy silt loam with••T�[ THE ABSORPTION FIELD SHALL BE INSTALLED PER THE REQUIRED SETBACK DISTANCES: 00 'z cobbles material to 0.3 to 5 feet below the surface. The soils become increasingly rocky with depth and 10 feet from any property line. appear to be consistent across the site.INSTALL CHAMBER END CAP ON ALL END CHAMBERS20 _ �\ �" A 8`1-411111.1 1• 25 feet from any potable water supply line. feet from any occupied dwelling. The native soils sampled from 1 2 feet below the surface are characterized as a soil type 2 soil consisting `� PROPOSED100 \ P 1 A / •- )H_12___,VVfor kj. TI1I feet from any well, spring or cistern. of sandy gravelly silt loam texture with moderate granular structure. This soil has an effective loading rate 25 feet from drainage swale or ditches conventional soil treatment of 0.6 Gal/S.F/day for a level 1 conventional treatment system. Soils INSTALL 4" RISER PIPE INSPECTION PORTON ONE OFPOLETENANT EACH PAIRED END CAP PENETRATION (TYP.) THE 1.25" FLUSH BALL VALVE ON THE R K I N G below 2 feet are increasingly rocky and are characterized as Type R1 soils with rock content greater thanDISTRIBUTION SYSTEM NOTES: 35%andlessthan65%with50%oftherockcontentsizelessthan3/4inch.TherockysoilsatdepthhaveABOVE 1. EFFLUENT FROM THE SECONDARY SEPTIC TANK COMPARTMENT WILL FLOW TO THE PERFORATED DISTRIBUTION LATERAL (TYP.) ir , es_k • I-A _ an effective loading rate for of 0.8 ermS.F./day for level 1 treatment system. Due to limited area and THIRD COMPARTMENT THAT HAS A BIO TUBE DOSING BASIN WITH A SIMPLEX HIGH to provide optimal treatment an intermittent sand filter is recommended to provide for a treatment level _ th f 0 I l 'T OpO SF _ ]� k�q V.excavation. TL3 sand filter system. No free water was encountered in excavations observed on site. Normal HEAD EFFLUENT PUMP ASSEMBLY. EFFLUENT WILL BE EQUALLY DISTRIBUTED TO THE TREATMENT BED VIA THE SPECIFIED INDIVIDUAL TRANSPORT LINE TO THE PRESSURE Groundwater levels are expected to be below 10 feet from the existing surface grades. The soils are MANIFOLD AT THE HEAD OF THE BED. (SEE PLAN CALLOUTS NOTES) suitable for the installation of a sand filter treatment bed system consisting of a minimum 24" depth of secondary sand Media that will be fully pressure dosed meeting the requirments under sections 2. THE SPECIFIED CUSTOM PERFORATED PRESSURE DISTRIBUTION LATERALS PIPES WILL BE (43.10. C, D,E,F&Hand 43.11.C.). INSTALLED BELOW THE CENTER OF THE SPRAY SHEILD CHAMBER ROWS ON THE SAND Additional soil evaluation will be performed during construction to verify the soils in the entire field LAYER SURFACE. THE DISTRIBUTION LATERALS WILL HAVE SELECT DIAMETER ORIFICES DRILLED AS SPECIFIED AT EQUAL INCREMENTS ALONG THE PIPE. (SEE PLAN CALLOUTS) Intermittent Sand Filter Treatment Unit/ Absorption System Design: 3. THE DISTRIBUTION SYSTEM SHALL DISTRIBUTE FLOW EVENLY ACROSS THE INTERMITTENT -ielf G r \ r A . F I l , - GRAVEL _ SAND FILTER BED. THE MINIMUM SLOPE OF THE TRANSPORT PIPE FROM THE DOSING The treatment/absorption field is designed based on utilizing the effective Long Term Acceptance Rate TANK TO THE PRESSURE MANIFOLD SHALL SHALL BE A MINIMUM 2.5% TO ALLOW FOR (LTAR)for an intermittent sand filter treatments stem utilizingpressure dosed distribution laterals and Y DRAIN BACK. ALL DISTRIBUTION PIPING, CONNECTIONS AND FITTINGS SHALL BE gravelless chamber units as spray shields.. The new treatment system will consist of a fully pressure dosed WATERTIGHT AND INSTALLED TO INSURE EQUAL DISTRIBUTION THROUGH THE SYSTEM. sand filter Treatment bed System with a 24-inch layer of filter sand (ASTM-33, "washed ASTM-33 Concrete sand"). ELECTRICAL NOTES Long Term Acceptance Rate (LTAR) 1. AN ORENCO SYSTEMS CONTROL PANEL SHALL BE INSTALLED BY A QUALIFIED INSTALLER Considering the application of the new state regulation 43: IN COORDINATION WITH THE ELECTRICIAN. A 110 VOLT ELECTRIC SERVICE IS ADEQUATE FOR THE PUMP SYSTEM. THE POWER SUPPLY FOR THE PUMPS AND CONTROLS SHALL , t //_ DRIVEWAY . i /r ■ r i-.Tr, , • - Receiving septic tank effluent, the treatment level for intermittent sand filters is considered TL3 for the minimum 24" depth of treatment media with the upper infiltrative surface being at least 4-feet above a CONSIST OF (1) 20 AMP DOUBLE POLE CIRCUIT FOR EACH PUMP AND 10 AMP SINGLE POLE CIRCUITS FOR CONTROLS. PANELS TO BE INSTALLED IN LINE OF SITE WITH TANK limiting layer; AND/OR PUMP BASINS. Maximum hydraulic loading rate for TL1 effluent applied to "Secondary Sand Media" in an unlined sand filter is 0.8 gal./sq.ft./day, or the long term acceptance rate of the receiving soil Type 2 R-1 for TL3 (1.1 2. THE CONTRACTOR SHALL INSTALL ELECTRICAL SUPPLY WIRE IN CONDUIT FROM THE gal./S.F./day) (Table 10-1 &10-1A) whichever results in the larger area. SERVICE PANEL TO THE WALL MOUNTED CONTROL PANEL. The maximum Loading rate is therefore 0.8 gal./sq.ft./day Loading factors; (Table 10-2, pressure dosed application bed = 1.0) 3. THE SYSTEM QUALIFIED INSTALLER SHALL INSTALL ELECTRICAL DIRECT BURY WIRES OR WIRES IN CONDUIT FROM THE CONTROL PANEL(S) TO THE DISCHARGE PUMP A(sf) = Qd x LF1 = A = Area; ASSEMBLY'S EXTERNAL SPICE BOX ON THE RESPECTIVE RISER OVER THE TANK PUMP 1 - ��J •118. Y ii = LTAR LTAR = 0.8 Gal/S.F./day for secondary sand, ASTM-33, " Concrete sand" BASINS. INSTALL CODED WIRES PER CONTROL PANEL DIAGRAM. INSTALL ALL WIRES FOR Qd = flow (gal/day) = 675 gpd PUMP AND CONTROLS WITH CONDUIT SEAL AT SPLICE BOX. ELECTRICIAN TO LF1=1.0 pressure dosing COORDINATE W/ SYSTEM INSTALLER. INSTALLATION CONSULTATION BY VALLEY PRECAST, INC. A(sf) = 675 gpd x 1.0 = 840 S.F. PEI * ._...•1. 0.8 Gal/S. F./day TESTING, INSPECTIONS AND CONSTRUCTION MANAGEMENT - GRA CALF MAILBOXES R ADDITIONAL INSPECTIONS AND RECOMMENDATION WILL BE MADE BY THE ENGINEER Excavate a single 70' by 12' bed to a maximum 3.5' depth below finish grade. Backfill with 24 inches of DURING CONSTRUCTION TO APPROVE THE LAYOUT OF THE TREATMENT FIELD SYSTEM, ASTM-33, concrete sand. Install 3 rows of custom perforated 1.25-inch distribution laterals on top of sand VERIFY INSTALLATION OF SPECIFIED MATERIALS AND OWTS COMPONENTS. layer in the bed and cover with 16 Quick-4 chambers per row for use as pressure dose spray shields, as delineated on the plan. 2. PRIOR TO CONSTRUCTION OF THE PERMITTED SYSTEM THE ENGINEER SHOULD BE C 20 0 10 20- 40 80 #5 REBAR -ir Sr IP CONTACTED BY THE PROJECT MANAGER/CONTRACTOR WELL IN ADVANCE TO PROVIDE ADEQUATE TIME TO DISCUSS THE SYSTEM COMPONENTS WITH THE CONTRACTOR, •r IP • N FEET) +THE 1 I fi .- w. \ t i 1500 Gallon Top Seam Three Compartment # with High Head Pump GNlee Total Velums) ANSWER QUESTIONS, RESOLVE ANY CONFLICT ISSUES AND SCHEDULE INSPECTION SITE VISITS BASED ON CONSTRUCTION PROGRESS. A PRE-OWS CONSTRUCTION MEETING WITH ENGINEER, THE CONTRACTOR, ELECTRICIAN AND THE QUALIFIED INSTALLER IS REQUIRED PRIOR TO INSTALLATION OF THE OWTS COMPONENTS. Z J DRAWIN( - �z 1500T-3CP-HH (2000 CONNECT 1.25" TRANSPORT LINE REGULATIONS REQUIRE THAT THE DESIGN ENGINEER OF RECORD PERFORM SITE ler3. INSPECTIONS OF THE PERMITTED SYSTEM DURING CONSTRUCTION AND PROVIDE TO 1.25" PRESSURE MANIFOLD. TRANSPORT PIPE INVERT A MIN. d r : • .. - AL OFFICE D1-321-00-0 )UNTY, CO :NT SYSTEP - APPLICATION SEED AND MULCH FINISH SURFACE 2" HIGHER THAN INVERT OF MANIFOLD TEE CONNECTION. USE 45°OR 22.5° FITTINGS. CROWN FIELD TRENCH TO MAINTAIN SUITABLE VEGETATIVE COVERn sry Nn r C "AS CONSTRUCTED" DOCUMENTATION OF THE INSTALLED SYSTEM TO THE THE COUNTY AFTER CONSTRUCTION IS COMPLETE. WE RECOMMEND THAT INSTALLED OWTS COMPONENTS BE SURVEYED TO OBTAIN REQUIRED AS-BUILT INFORMATION. DIVERT SURFACE WATER 1.25" SCHD-40 PVC PRESSURE MANIFOLD W/ INDIVIDUAL TOPSOIL 1.25" SCHD-40 PVC 1.25" TEES OR ELBOWS TO 1.25" CUSTOM PERFORATED DISTRIBUTION MANIFOLD DISTRIBUTION PIPE • Design per performance test per Ascot c1227 • Top surface orea 87.75 ft' 78' • fc 0 28 days; concrete = 6,C-00 PSI MM in stet aSiOrt Ow Amos 1t rilik �{ I, f' 4. COUNTY REGULATIONS REQUIRE THAT THE COUNTY ENVIRONMENTAL HEALTH DEPARTMENT BE NOTIFIED TO SCHEDULE AND PERFORM A SITE INSPECTION OF THE EXISTING GRADE CHAMBER END CAP •TAnk to lag set an 5' m:n- sand bed or pea `!lave! • Tank to ben bask uniformly on V"(rI F' F € II ' PERMITTED SYSTEM DURING CONSTRUCTION PRIOR TO BACKFILL OF THE OWTS COMPONENTS. all sides in lifts less than 24" end less -• -r T� - - - r ......... • �.... ► ` = -. r�-_; A•_a«•r mechanically compacted • - - 5. CONTRACTOR SHOULD DISCUSS ISSUES REGARDING SPECIFICATIONS, INSTALLATION AND �..) C�U-... W • • .i • ...........' i. i'`i'`i" i • • . • • • . - - 12" 8" Pump Selection Fora Pressurized System-Mueiple Family ResieenceProiec' i��• Excavated material moy be used for Top backfill, large C G � • �.�.. =• ....... • . • •: • i • • •.,' . i •. •. • ......._•- -_ ilai 17352RIghwa882Profesaonaloffiea."a5eldCounN,5T5god full pressuredosedaandrlter �r� provided stones ore VL8Y1f OPERATION OF OWTS MECHANICAL SYSTEMS AND CONTROLS WITH THE N .. �, �, �, �, �, �, �, �, �, �, �� f 1 50 TYP �: - - ��, .:� / MIN. MAX. i •removed vlroii•ta..._. • Excavation should be dewatered anal Hyl: SUPPLIER/INSTALLER AND/OR THE ENGINEER. - 0 I- �, �, �, �, �, •s - A �. �. �. �. � �s A s AAAA 0.5' (TYP.) ■ rolf Parameters ws `1ut • funk filled 1th water prior la being - �r I� / �W• Boot • r /'��FF� J C/ J• LLJs • 1 �,'. ._J- \24"79".4r.'i / oarnargaassemows�a Iso Inrnea anep°nren9,n a feet 1Pr ',a \ p In service for Installation with k water table less hon 2' treHaw grade tfor >..- yam 6. OUR DESIGN AND RECOMMENDATIONS ARE BASED UPON OUR EVALUATION OF THE ,'1.0'(TYP.) w w I V Transport PIpe Class 40 '�� Orono Systems' • Meets 01644-D6 resttent ,• dr4kiNSTSIS +• EXISTING AND PROPOSED SITE CONDITIONS AND INFORMATION SUPPLIED TO US BY L1J (%� \,�� �' amp° Pnes e ,ss Inches DIsv^uen9 valve Model None Incorporated amsi,�,r tlroydir connectors • Inlet one Oudot identlt3ed abase pipe Delivered internal t I _ ••Ili - t II OTHERS. IF SITE CONDITIONS ARE FOUND TO BE DIFFERENT FROM CONDITIONS ASSUMED w �.�/ ! , 1..1. t /�/ L.I. tW.!t7Ma/!�`�c!c%��� • N.T.S. Max Llpva,mn LAt s fee, • complete with piping Q ~ Q UNDISTURBED EARTH / - Manifold Length 9 fee, �� Manifold Pipe class ao •♦ trvurx PY,t or.f° • Secondary safety screen avo7able with PVC riser i JiE 1 OR INDICATED, WE SHOULD BE NOTIFIED TO EVALUATE ANY EFFECT ON THE PROPOSED OWTS. S O ! I•'1 LJ Manifold Pipe Sze 125 Inches rvteral °f Laterals per cell 3 1 „ �+ y 4 /r \` COSTUME PERFORATED Lateral Length 64 pe, - w SCREENED BACKFILL // NATIVE SOIL 24" PRESSURE PIPE WITH / a,eralPlpeClass `° a,eral Plpe l e 2 ee \` ALLOWABLE BURY - 'I'll 5. CONTRACTOR SHOULD REVIEW ANY CONDITIONS ON THE ISSUED PERMIT AND J I- 0 1.25" TEE CONNECTION ORIFICES AT 12 0 CLOCK NATIVE, YARD OR ResidSi,, 5132 Inchea oencesparing 3 fee, (Bases on water Tohie} ll - COORDINATE WITH THE ENGINEER REGARDING CONSTRUCTION OF THE SYSTEM. Q Q CL n Residual Rend 3 feet Ire, �(� sCL N Q SECURE PIPE WITH PUSH IN LANDSCAPED SURFACE nwMeter Mene Inehea w dal Fd"I°° tl fee, WATER TAME E,"� 1• ----� - - 6. IF YOU HAVE ANY QUESTION OR NEED ANY ADDITIONAL INFORMATION, PLEASE CALL U 00 INTERMITTENT SAND FILTER LAYER °^ °sees v _ ice, J Z D STAPLES \ ° - ° 3 - ° PAUL RUTLEDGE AT SOPRIS ENGINEERING, 704 0311. SIZE 0.25 0.6 MM, WITH r Calculations - Ui BUILDING PERMIT QUICK-4 INFILTRATOREFFECTIVE UNIFORM. COEF.=<4.0 USE nnlmnmFlowRa,epercrinee osz gpm OR EQUAL BIO DIFFUSER \ / / / CONCRETE SAND-ASTM-33Nu�IbeoofR3,ef3isZe,Zone Mumoergforlfcespeizpne a5 = z' - o• 4' - a 181, °'�°�1e1*Q fot111d m O�� SHIELDS \\ \\ \\6" MIN. \ \ \ 352 Spm "° per \ Fplaltprya0rntaom.YlbYron (nSPRAY \ - o' a - v^ Tranaportvelodryze IDs d'-°"PRESSURE QDRY \ �� w� RFLAND '352 HIGF C 71// DISTRIBUTION PIPE12' MIN• Fnctienel Head Losses °F', i51CLlfNtig lxldtMllipplOCMkNATIVE GRAVELLY SILT LOAM6" MIN. ' EXCAVATED MATERIAL °aa,hrnu9holarhar9e a7 oe, I-- \ +fmRlllM4tlwISl1>aier• THROUGH END CAPTE WITH COBBLES o COMPACTED TO 90% °es inTransp°" eel 0o fee, 'Si9IV1�C01�fisGtBlvl��h�lbr►IJIlb�11R110>f• r,��,CONNECTED itte� '��� . • r�rTO wSOIL CUSTOM PERFORATEDEINTERMITTENTSAND FILTERBEDMUSTBELEVEL. INSTALLCHAMBEARSWITH INLET AND PROCTOR ossmrpu9hvame eaai^Lianlfple as oe' A�Di _ __e►' ggin specs nve t 6irneneions l4et Capacity Net weight g +' �� `,,STANDARD LATERAL PIPED CAPS OVER SAND LAYERT FOR USE AS SPRAY SHEILDS. INSTALL INDIVIDUAL Agasihrpughrlpwme,er o5 fee, og oe, •Qr�•��+DISTRIBUTION */ LATERALS TO THE HEAD OF EACH CHAMBER ROW FROM MAINIFOLD �iA aeo-gn FnClgn °ssee o o fee, 15' Long x S' Wide Inlet Olutlet Len th 468th Height Inlet Side Middle Oullet Total Lie Tont Tolol g • r'STRIBUTION • (n SCARIFY/TILL BOTTOM SURFACE AND CONNECTING EACH CHAMBER ROW. CUSTOM PERFORATED PIPE TO BE LAID ON TOP OF 4" MIN. Pipe Volumes 56• below Inlet 56" 73" 182- 78" 92" 10t6 gal 505.gal 507 gal 2028 gol 5420 be 16240 lbs 26860 lbs ; . • Z SUITABLE BACKFILL OR EXCAVATION SIDE WALLS THE SAND LAYER WITH ORIFICES ORIENTED UPWARD EXCEPT THE FIRST AND LAST ORIFICES ��� vnlnrTranepsdLme os gale �^= CLASS 6 ROAD BASE ' ' 4" Vol ofMandold 0.7 gals '° 149 gals olofLltme �\ _ _ re= W#IMrdr p� 20305 Co. o► 2f3377 0 TO BE ORIENTED DOWNWARD. INSTALL A 4" VERTICAL INSPECTION RISER FROM THE rF TotalV lumeaperZone 16.2 gals " mo P.O.�I� 12/09/20 f �•� MOLDED CUT OUT ON THE LAST CHAMBER IN EACH ROW. INSTALL A BALL VALVE AT THE COMPACTED SUBGRADE Minimum Pump Requirements ��OdBf�i \ 01°55" -■A= * �� • �� Voir-VALLEY r,l , r; a ' ' END OF THE DISTRIBUTION LINE ACCESSIBLE FROM THE INSPECTION PORT TO ALLOW Design Row Rate 35.2 9prn -0 am o Fax 1 � • Produet6 : • ,•'9 +1 ,� •' . . " FLUSHING OF THE LINE. THE VALVE IS CLOSED FOR NORMAL OPERATION. eialDynamic Head 8 feetDamtp wows: WWWValleYI CEKSZCOM ':5, , , . • • •' Ponto PRECAgr' nc. • C6 kj �kc...•` TRENCH CROSS-SECTION FOR , o Net Discharge igpmj� Ee►Wr:nlonoaesowalleyp+e�lstean � ;,tt DATE: DEC 9, 2020 PRESSURE DOSED INTE'RMITTE'NT SAND FILTER ti (S'YS'TEM SDR-35,26 OR SCHD-40 PIPES JOB NO. 30201.01 WITH CHAMBER SPRAY SHEILDS N.T.S. G:\2020\30201-ALBRIGHT\CIVIL\CIVIL DWGS\DE\30201-DE-OWTS PLAN.DWG - Dec 09, 2020 - 2:08pm SHEET C2