Loading...
HomeMy WebLinkAboutObservation of Excavation 11.08.2019li+A Kumar & Assoclatzta, Inc.* Geotechnical and Materials Engineers and Environmental Scientists 5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Employee Owned Company www.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado November 8, 2019 Jacob Sampson c/o Alii Construction Attn: Felipe Sales 8000 County Road 313 New Castle, Colorado 81647 aliicmnstruction51 rt. �nail,c ottz k Issacatpatgamikei SYVN.WAfiRj1A [6m Project No. 19-7-672 Subject: Observation of Excavation, Proposed Garage/Shop Attached to Existing Residence, 1159 County Road 259, Garfield County, Colorado Gentlemen: As requested, a representative of Kumar & Associates, Inc. observed the excavation at the subject site on November 7, 2019 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation design are presented in this report. The services were performed in accordance with our agreement for professional engineering services to Jacob Sampson, dated November 6, 2019. H-P Geotech (now Kumar & Associates) previously observed the excavation for the existing residence as described in a letter dated June 21, 2016, Job No. 116 253A. The proposed shop will be 30' by 30' in plan size, one story with a slab -on -grade floor. The garage will be attached to the east side of the existing house. The foundation will consist of 18-inch wide continuous concrete footings with CMU block foundation walls. At the time of our visit to the site, the foundation excavation had been cut in one level from 2 to 3 feet below the adjacent ground surface. The soils exposed in the bottom of the excavation consisted of medium dense, silty sand. Results of swell -consolidation testing performed on a sample taken from the site, shown on Figure 1, indicate the soils have low compressibility under light loading and a low collapse potential (settlement under constant load) when wetted. The soils were moderately to highly compressible under increased loading after wetting. No free water was encountered in the excavation and the soils were slightly moist. Considering the conditions exposed in the excavation and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 1,500 psf can be used for support of the proposed garage with a risk of settlement if the bearing soils become wet. The exposed soils tend to compress when wetted and there could be differential post -construction settlement of the foundation if the bearing soils become wet. Footings should be a minimum width of 18 inches for continuous walls and 2 feet Jacob Sampson November 8, 2019 Page 2 for columns. Loose and disturbed soils and any existing fill in footing areas should be removed and the exposed bearing soils moistened and compacted. The bearing soils should be protected against frost and concrete should not be placed on frozen soils. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous foundation walls should be heavily reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 14 feet. Structural fill placed within floor slab areas can consist of the on -site soils compacted to at least 95% of standard Proctor density at a moisture content near optimum. Backfill placed around the structure should be well -compacted and the surface graded to prevent ponding within at least 10 feet of the building. Landscape that requires regular heavy irrigation, such as sod, and sprinkler heads should not be located within 10 feet of the foundation. Consideration should be given to the use of xeriscape near the garage. The recommendations submitted in this letter are based on our observation of the soils exposed within the foundation excavation and do not include subsurface exploration to evaluate the subsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling would be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, Kumar & Associates, Inc. F Daniel E. Hardin, P.E. ;c 24443 2: ,..,'' "//t 1 Imo[ ''4; A 5��l- - - --- GAR . attachment Figure 1— Swei onsolidation Test Results Rev. by: SLP DEH/kac Kumar & Associates, Inc.', Project No. 19-7-672 1 0 —1 -J —2 W N — 3 z 0 1- 4 J— u z O —5 — 6 — 7 — 8 9 SAMPLE OF: Silty Sand FROM: Footing Grade at Southeast Corner of Garage WC = 5.5 %, DD = 92 pcf ADDITIONAL COMPRESSION UNDER CONSTANT PRESSURE DUE TO WETTING Them loel moles op* only eo lne. mpMa'tiled, the le.linp I enact not 6e he wrIllee approval In fug. .dowel the weillon npproval of KWnpo and Meoelotn. I. Swell ConeotaaSon kelfny performed in waMh ocrdon•A [ei 1,0 APPLIED PRESSURE - KSF 10 100 19-7-672 Kumar & Associates I SWELL —CONSOLIDATION TEST RESULTS Fig. 1