HomeMy WebLinkAboutEngineer's Letter for Joist EvaluationGmail Letter for Joist Evaluation on 2019-063 Delaney Res (YLH) Kris Bennett <kris@designintel.com> Fri, Jul 31, 2020 at 3:20 PM To: Michael Kuhn <midriverswest@gmail.com> Cc: Josh Wood <josh@designintel.com>, Jeanine Harrop Hansen <admin@designintel.com>, drdelaney53@gmail.com, rjdelany@rof.net Michael, The single log header above that window is okay as a 12" Round West Wood Wall Log 30 even with the extra span for the bucks with the settling gap. Also, to me it looks like the electrician used the precut holes that come with the joists so I don't think that's an issue. Let me know if you need anything else from us. Thanks, Kris Bennett, P.E.* *I D,WY,MT,UT,CO,AZ,WA,OR,NV,MN Design Intelligence LLC 1037 Erikson Dr. Rexburg, ID 83440 Phone 208-359-1461 Fax 208-359-0740 Email kris@designintel.com NOTE: This is a confidential communication and may contain privileged and/or confidential information. If you are not the intended recipient please delete this message and attachments and do not read, copy, or disseminate the message or any attachments. If you have received this communication in error please notify us immediately. Neither the transmission of this message or any attachment, nor any error in transmission or misdelivery shall constitute waiver of any applicable legal privilege. [Quoted text hidden] e.a*µ • r+rate DESIIGN ENCE LLC ,•► 0 oLsIah Date: July 22, 2019 The Right Fit TEL 208.359.1461 FAX 208.359-0740 ({R IS @ DESIG N I NTE L.COM To: Garfield County Colorado Building Department Subject: Delaney Residence File No: 2019-063 Dear Sir or Madam, 1037 ERIKSON DRIVE REXBURG, ID 83440 WWW.DESIGNINTEL.COM The plan south walkout basement wall shall be changed from concrete to framed wall on the above - referenced Design Intelligence LLC plans dated 4/29/19. The wall shall be an S1 shear wall (as noted on page S4) with (4) Simpson STHD10 hold downs equally spaced along the wall. Please call if you have further questions. Kris Bennett, P.E. Design Intelligence, LLC 07/22/19 Page 1 of 1 �Lyu�Fy 1YCr ye ESlIN LLLOGEN Date: June 22, 2020 The Right Fit TEL 208.359.1461 FAX 208.359-0740 KRISPDLSIGNIN I EL.COM To: Garfield County Colorado Building Department Subject: Delaney Residence File No: 2019-063 Dear Sir or Madam, 1037 ERIKSON DRIVE REXBURG, ID 83440 WWW.DESIGNINTELCOM The 9.5" BC 6000-1.8 DF joists at 12" o.c. spanning 4'-0" shown on page S2 of the above -referenced Design Intelligence drawings dated 8/13/19 have been evaluated for cutting (3) holes laid out as follows: 4" DIA. r— I" DIA. CENTERED ' ALONG FLANGE With holes sized and located approximately as shown, the joists are adequate as sized without any additional reinforcing added. Please call if you have further questions. Sinrely, Kris Bennett, P.E. Design Intelligence, LLC Page 1 of 1