Loading...
HomeMy WebLinkAboutAs-built 12.23.2018Dec 23, 2018 Garfield County Building & Planning 108 8th Street, Ste. 201 Glenwood Springs, CO 81601 RE: Harris OWTS - 3200 CR 237, Silt. CO Permit No. SEPT-03-15-3582 BUI #17008.01 To Whom it May Concern: Civil Engineering Surveying & Beyond cedar•. This letter addresses an on -site review of an Onsite Wastewater Treatment System OWTS installation for a new 3 bedroom single family residentence located at 3200 CR.237 in Garfield County, CO. Boundaries Unlimited Inc. (BUI) performed an inspection during the systems construction on June 1, 2017 and reviewed the backfill and grading shortly there after. The installation included a 1,000-gallon concrete septic tank, Concrete distribution box for three trenched rows of Quick 4 Infiltrators, 4" inspection port pipes at each end of inflitrators, and associated piping. Depth of cover over infiltrators was requested to be reduced to approximately 18" during backfilling. The OWTS system appeared to have been installed in conformance with the intent of the design and Garfield Courty regulationS . Attached are construction photos and an asbuilt and PDF Drawing If you have any questions, please feel free to contact me at 970-456-4692. Sincerely, BOUNDARIES UNLIMITED INC. .' ti4 ;got E U. 1, ,'te a r Principal �e+.e} 4ry �dRltt#''#' �1 CC: Albert Harris <acharris54@gmgFI.°com> venue, Ste. 201 I Glenwood Springs, CO 81601 I 970.945.5252 I www.bu-inc.com 923 Cooper Avenue, Ste. 201 I Glenwood Springs, CO 81601 I 970.945.5252 I www.bu-inc.com 20 GRAPHIC 0 10 20 SCALE 40 80 CONCRETE LID \fr FINISH GRADE �/ 6"TOPSOIL (MIN.) CONCRETE LID 7 V V ( IN FEET ) 1 inch = 20 ft. -I I -I I -I I •!_ -I I I I -I I- ATTACH REMOVABLE CAP OR - - _ - -_ - .p- o - -P-RR C STRIE - - Il Foefers 100' WELL RADIUS /SIOPO 4" SCH 40 PVC GRAVITY PIPELINE FROM HOUSE CONCRETE TWO CHAMBER SEPTIC 1,000 GAL (MIN)) �e vHwnv BAVEL Well , , f Q�' Gate rToe ofSlope o THREADED CLEANOUT ASSEMBLY. / ' / ' / \/, D . n % ' f) A D .p A• \/\/\ INSTALL MARKER IF CAP IS TO FINISH GRADE BE BURIED. ������ \// /\ D 3 N/�\ �/ \ \ 6Boulder / 18" ' , IN INFLOW SHALL ENTER THE I 4"0 PVC RISER \• \/ �� %% • w E > eL , s/ LARGER CHAMBER %\\� � � NOTE: c 4" PVC WYE 4"0 45°BEND \i ` -- STATE APPROVED 1,000 GALLON �\ \�� /\ FLOW I II % " �. TWO (2) CHAMBER CONCRETE Cleanout 4"0 SEWER LINE \\ �// ��, SEPTIC TANK. /\ j\ " SPLITTER BOX 4" PVC OBSERVATION PIPE (BOTH ENDS) Te PI #p CONSTRUCT A 6" DRAINAGE SWALE 1 UPSLOPE FROM THE ABSOROPTION TRENCHES AREA Teti Pit 443 \l • # 54-INFILTRATOR QUICK4 CHAMBERS .* .* ` IN THREE TRENCHES (AS SHOWN) • OR �• �• # \ 36-ADS BIODIFFUSER (STD) CHAMBERS .• .• .• �Tes Pit#1 IN THREE TRENCHS (NOT SHWON ..� ..� .. Teti Pli Pz PROVIDE 6' MIN SEPARATION # # e Teri Hole • illIO 8'Teef Hole #1 ' IIII N.T.S. 0 • • \�j\ \\' e .. nv�uv„� v 1" CRUSHED Septic 0 ROCK, 6" DEEP TO Tank LEVEL TANK w ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO BE BURIED. FINISH GRADE N.T.S. BETWEEN EDGE OF TRENCHES '...:..;..,.� PROVICE 15' MIN SEPARATION BETWEEN '• •• TRENCH FIELD AND FENCE 7 Fence i Fence 41111111111111"--PROPERTY LINE Proposed County Road Easement Edge of Asphalt Edge of Asphalt C/LStripe t• 237 I I Site plan ONSITE WASTEWATER TREATMENT (OWTS) 4"0 PVC RISER WASTEWATER TREATMENT FOR THE NEW RESIDENCE LOCATED AT 3200 COUNTY ROAD 237 SILT, CO WILL BE HANDLED BY A NEW 4" PVC WYE /� 4"0 45° BEND ONSITE WASTEWATER TREATMENT SYSTEM (OWTS). THE OWTS DESIGN WAS COMPLETED IN ACCORDANCE WITH GARFIELD COUNTY COMMUNITY DEVELOPMENT DEPARTMENT'S ON -SITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATIONS. FLOW 11 I1•1I II $THE PROPOSED THREE (3) BEDROOM RESIDENCE WILL BE CONSIDERED FOR DETERMINING MAXIMUM DESIGN FLOWS. 41'0 SEWER LINE Two Way Cleanout DESIGN CALCULATIONS: DESIGN WASTE WATER FLOW (SEE SEC 43.6 A.2. a & f): 0 N.T.S. 75 GPD/PERSON X 2 PERSONS/BEDROOMS X 3 BEDROOMS = 450 GALS/DAY SEPTIC TANK SIZE: 3 BEDROOMS = 1,000 GALLON CAPACITY TWO COMPARTMENT TANK (SEE TABLE 9-1). TANK. TANKS ARE NOT SUBJECT TO BUOYANCY. SOIL TREATMENT AREA: 0 N.T.S. ACCORDING TO THE SUBSOILS EXAMINED IN TWO 8 FT DEEP TEST PITS ON MARCH 24TH, NO GROUNDWATER ENCOUNTERED IN THE PROFILE TEST PIT, THE AVERAGE PERCOLATION RATE WAS DETERMINED TO BE 38 MINUTES PER INCH (MPI), AND THE SOILS ARE "TYPE 3." (RELATIVELY DENSE, CLAYEY SILTS WITH COBBLES). GROUND SURFACE SLOPE MEASURED BETWEEN 9 TO 15 PERCENT IN THE SOIL TREATMENT AREA, WHICH IS LESS THAN 30%. THE SYSTEM SHALL BE BE DESIGNED UTILIZING THIS INFORMATION WITH A TREATMENT LEVEL 1 LONG TERM ACCEPTANCE RATE (LTAR) OF 0.50 GPD/SF. (SEE TABLE 10-1). GENERAL ABSORPTION AREA NOTES AREA = DESIGN FLOW (GALS/DAY) = 450 = 900 SF (SEC 43.10 C) SET BACK DISTANCES LTAR (GALS/DAY/SF) 0.5 SIZE ADJUSTMENT FACTORS: TRENCH, GRAVITY FLOW =1.0 (TABLE 10-2) DISTRIBUTION MEDIA (CHAMBERS) = 0.7 (TABLE 10-3) ADJUSTED AREA = 1.0 X 0.7 X 900 SF. = 630 SF 1. SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1(TL1) STA TRENCH/BED, UNLINED SAND FILTER OR OPTION #1: INFILTRATOR QUICK4: 630 SF/12 SF/UNIT = 52.5; USE 54 UNITS IN TRENCH CONFIGURATION. 1. INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. ABSORPTION TRENCHES SHALL BE 3' WIDE , AND SHALL BOTTOM TO BE LEVEL AND FLAT OVER PARALLEL THE TOPOGRAPHY. TRENCHES SHALL HAVE A MIN. ENTIRE AREA TO WITHIN 005= (TYP) IF NECESSARY, LEVEL SURFACE AREA OF 6' DISTANCE BETWEEN THEM. WTHIMPORTED CONCRETE SAND 3. THE BOTTOM OF THE ABSORPTION BED SHALL BE LEVEL AND >�i/��i�` j�� 1\j� THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE \!p!p!p ''�/' ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. i>\i/\/• ��•�� FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO ���������. REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. A``p• /✓ . . FINISHED GROUND - MAINTAIN POSITIVE SLOPE AWAY FROM TOP SURFACE OFTHE SEAHOPUNc(TNION) CHAMBER TRENCHES USEAHOLE SAW TO CUT OUT CIRCLE OFF THE CENTER OF THE UNIT •��\� �- _ ���������/���/�c�p�/�/,�/ �j/`��/`��/``/`��/`��/`��/`��/`��/`��/`�i/`/`�.� //.p //. STANDARD CUT TO FIT REMOVABLE INSTALL MARKER • _ z _ N T INSPECTION PORT, TYP. (4"0 PVC SOLID PIPE LOCATE PER PLAN VIEW.ATTACH CAP OR THREADED CLEANOUT ASSEMBLY. IF CAP IS TO BE BURIED. X Q _ 4"0 PVC SOLID M PIPE CUT TO FIT SRAVELLESS CHAMBER SYSTEM wRLTRATORQUICK 4,ADVANCED DRAINAGE SEEPAGE PIT (PER TABLE 6.28-1&2) AND AND ADWF=1000 GPD: 1.A. SPRING OR WELL=100' 1.B. POTABLE WATER SUPPLY LINE=25' 1.C. POTABLE WATER SUPPLY CISTERN=25' OPTION #2: ADS BIODIFFUSER (STD): 630 SF/18.75 SF/UNIT= 33.6; USE 36 UNITS IN TRENCH CONFIGURATION. NOTES: 1.D. DWELLING=20' 1.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH-10' - 1.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' 1.G. LAKE, WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=100' 1.H. DRY GULCH, CUT BANK OR FILL AREA=25' 1.1. SEPTIC TANK=5' 1.J. RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 2' (TREATMENT LEVEL 1, PRESSURE DOSING) 3. SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 6.28-1): 3.A. SPRING OR WELL=50' 3.B. POTABLE WATER SUPPLY LINE-10' 3.C. POTABLE WATER SUPPLY CISTERN=25' 3.D. DWELLING=5' 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH=10' 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=10' 3.G. LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=100' 3.H. DRY GULCH, CUT BANK OR FILL AREA=10' 3.1. STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PIT=5' 1. ABSORPTION TRENCH EXCAVATION SHALL BE INSPECTED BY THE DESIGN ENGINEER PRIOR TO PLACEMENT OF CHAMBERS 2. SYSTEM DESIGN IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FROM REVERSE OSMOSIS OR WATER SOFTENERS AND/OR FILTERS SHALL NOT BE INTRODUCED INTO THIS SYSTEM 3. CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS AND AT LEAST 100 FEET BETWEEN THE HOUSE AND SEPTIC TANK. 4. ALL PIPE, FITTINGS, AND CONNECTIONS SHALL BE WATER TIGHT TO PREVENT INFILTRATION. 5. CONCRETE SEPTIC TANK AND ABSORPTION FIELD SHALL NOT BE PLACED IN AREAS OF ANY VEHICLE TRAFFIC OR DRIVEWAYS. 6. A "POLYLOK, INC." EFFLUENT FILTER SHALL BE INSTALLED IN 2ND TANK CHAMBER AT OUTLET PER MANUFACTURER. 7. INSPECTION PORTS SHALL BE INSTALLED AT BOTH ENDS OF EACH ROW OF CHAMBERS. 100 LINEAL FEET IS MAXIMUM LENGTH OF CHAMBERS IN A TRENCH. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9. INSTALL 3-INCH THICK BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 3-FEET. GROUND COVER SHALL NOT BE LESS THAN 2-FEET. 10. SYSTEM COMPONENT LOCATIONS MAY VARY AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES COMPLY WITH REGULATIONS. 11. ALL SYSTEM COMPONENTS MUST BE INSPECTED BY THE DESIGN ENGINEER AND GARFIED COUNTY PRIOR TO ANY BACKFILL. 12. REMAINING SURVEY INFORMATION FROM OTHERS. 13. PERCOLATION TEST RESULTS AND SOILS EVALUATION PERFORME BY "BOUNDARIES UNLIMITED INC." ON MARCH 14TH, 2017. SUMMARY �\j/�\j/� 4. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND 400\ ��/••i��• ��/��.�r �`//�/ \\��\\\\\�\\\\\\\\\\\\\\\\ �N ��i��i�\ji��i��i\�ji�%ji��ji�i��i\�ji��ji��� SYSTEMS BIODIFFUSER (STANDARD), OR ENGINEER APPROVED EQUAL THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF \'��j��j/��//�//; Trench #1 FROM ENTERING ABSORPTION AREA. \ . 5. NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES `��j/��j��j/��j/��j��j/��j/�����j/��j/��j/��j/��j����� •\pppppppppppppp< 4444444444444 ����/��//��j��j/��j/��'��j/��j/��'��j/��j/��'��- \��j�\j/\j/\�//�\//�\//\�//�\//�\//\\//�� \\\\\\\/\\/�\"t / ! ! �I� 4"0 PERFORATED PVC PIPE. EXTENDON o TOMOFT TO OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. Trench #2 6. UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE 6' MIN. EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE OVEREXCAVATION. 7. TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 2-FOOT Typical MAXIMUM) TO ALLOW FOR LANDSCAPING. 36" Chamber Trench System N.T.S. TREATMENT IS PROPOSED AS A WASTEWATER TREATMENT LEVEL 1 AND A GRAVELLESS CHAMBER ABSORPTION FIELD IN A TRENCH CONFIGURATION. THE SEPTIC TANK WILL BE A 1,000 GALLON (MIN.) STATE APPROVED TWO CHAMBER CONCRETE TANK. THE ABSORPTION FIELD TRENCHES WILL BE GRAVITY FED AND THE MINIMUM REQUIRED SOIL TREATMENT AREA IS 630 SF (UTILIZING STORAGE -DISTRIBUTION CHAMBERS). $o Civil Engineering Surveying & Beyond nie 923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 tele: 970.945.5252 fax: 970.384.2833 Engineer or Surveyor ‘ �,\,D 0 L/C\4'ir 12/23/20 •• O 0 6 19082 •• � ‘y ON \�A��` Client Information: ALBERT & CHRISTINE HARRIS 3200 COUNTY ROAD 237 SILT CO 81652 (970 456-9883 Garfield County, Colorado Cp§ HARRIS RESIDENCE - OWTS P ) CCI 2CR 2 7SILT, PARCEL GRAND HOGBACK EXEMPT. CORR. PLAT a 3 OO 3, C 1, mb oP o OWTS „121 By Revision Date 6 z PROJECT ......-. NO. Sheet • 17008 FILE NAME: HARRIS OWTS Designer: Drafter: 1BDL I C Date: 04.03.17