HomeMy WebLinkAboutPermit. . e Garfield County
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT -6625
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 01/07/2021 Expiration Date 01/07/2022
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 17352 Highway 82, Carbondale, CO 81623 Parcel No.: 239132100043
Owner Name: RFLANDCO, LLC Owner Phone: (970) 379-3244
Designed By: Sopris Engineering, LLC. Designer Phone: (970) 704-0311
Number of Bedrooms: 5 Minimum Tank Capacity: 1,500 -gallon Minimum Absorption: 844 ftz
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the revised report and design as
submitted by Sopris Engineering, LLC. dated January 6, 2021. Changes to the design and permit must
be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will replace an existing undersized/failing system and will serve a four-bedroom
residence and 2 -bedroom ADU. The system will consist of a new, three -compartment 2,000 -gallon
septic tank set level with access to grade with an effluent filter in the outlet tee of the second
compartment and a pump in the third compartment. Effluent will pumped to a manifold set level
with access to grade distributing effluent to 846 ft2 of STA. The STA will consist of a sand filter
utilizing secondary sand media with effluent distributed via three effluent distribution rows, utilizing
16 'Quick 4' Standard infiltrator chambers per row for a total of 68 `Quick 4' chambers to distribute
effluent evenly across the filter. Effluent lines from the pump to the sand filter and across the filter
are to be 1.5 -inch schedule 40 PVC. Orifice sizing shall be 5/32 -inch on 3 -feet spacing on -center.
Orifices shall face up, except for the first and last holes in each row, to allow for proper drainage.
Inspection ports are to be installed at each end of each row. Maintain all setbacks and elevations as
designed.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
`� i - 6%t/E,
01/07/2021
Issued By: Garfield County Environmental Health
Department
Date